Skip to main content
Log in

New Technology for Preventing Residential Electrical Fires: Arc-Fault Circuit Interrupters (AFCIs)

  • Published:
Fire Technology Aims and scope Submit manuscript

Abstract

A new generation of residential electrical branch circuit breakers that incorporates technology to detect and mitigate the effects of arcing faults is described. Fire loss estimates attributed to electrical wiring and the development of the arc-fault circuit interrupter for the prevention of residential electrical fires are discussed. The industry voluntary standard for arc-fault circuit interrupters as well as the 1999 National Electrical Code requirement are reviewed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Ault, Singh, and Smith, “1996 Residential Fire Loss Estimates”, U.S. Consumer Product Safety Commission, Directorate for Epidemiology and Health Sciences, October 1998, Tables 1, 6, 10, and 14.

  2. Witt, Roger, Comment on Proposal Number 2–129, “National Electrical Code Committee Report on Comments”, NFPA 70-A98 ROC, State Farm Insurance Co., p. 106.

  3. Zlan Ltd Web Site, [On line] URL: http://www.zlan.com/arc.htm.

  4. Smith and McCoskrie, “Residential Electrical Distribution System Fires”, U.S. Consumer Product Safety Commission, 1987.

  5. Gregory, G. and Scott, G., “The Arc-Fault Circuit Interrupter: An Emerging Product”, IEEE Transactions on Industry Applications, Vol. 34,No. 5, September/October 1998.

  6. Engel, J., Clarey, R., and Doring, T., “Arc-Fault Circuit Interrupters: New Technology for Increased Safety”, International Association of Electrical Inspectors, 1997.

  7. NFPA 921, Guide for Fire and Explosive Investigations 1998 Edition, National Fire Protection Association, Inc., Chapter 14.

  8. Roberts, Earl, Overcurrents and Undercurrents, Electrical Safety Advances through Electronics, Reptec, 1996, Chapters 1–2.

  9. “Technology for Detecting and Monitoring Conditions That Could Cause Electrical Wiring System Fires”, Underwriters Laboratories Inc., U.S. Consumer Product Safety Commission, September 1995.

  10. “Report of Research on Arc-fault Detection Circuit Breakers for National Electrical Manufacturers Association”, Underwriters Laboratories, March 15, 1996.

  11. NFPA 70, National Electrical Code 1999 Edition, National Fire Protection Association, Inc., 1998, Article 210.

  12. The New IEEE Standard Dictionary of Electrical and Electronic Terms, Institute of Electrical and Electronics Engineers, 1993, p. 51.

  13. Technical notes “Fire Shield Cord Sets”, Technology Research Corporation, 1999.

  14. UL 943, Standard for Safety, Ground-Fault Circuit-Interrupters, Underwriters Laboratories Inc., August 1993.

  15. National Association of Home Builders, article.

  16. Yereance, Robert A., Electrical Fire Analysis, Charles C. Thomas-Publisher, 1987, pp. 132-138.

  17. UL 489, Standard for Molded-Case Circuit Breakers, Molded-Case Switches, and Circuit-Breaker Enclosures, Oct 31, 1996, pp. 33-46.

  18. “An Evaluation of Branch-Circuit Circuit-Breaker Instantaneous Trip Levels”, Underwriters Laboratories Inc., Electronic Industries Association, October 25, 1993.

  19. Block Diagram, Dr. Joseph Engel, Cutler-Hammer, January 1999.

  20. Product Brochure “Cutler-Hammer Arc Fault Circuit Interrupters”, October 1997.

  21. Gregory, George D., “Using Arc-Fault Circuit Interupters to Reduce Residential Fires”, EC&M, November 1997.

  22. Meese and Beausolei, NBSIR 77-608341: “Exploratory Study of Glowing Electrical Connections,” October 1977.

  23. UL 1699, Standard for Arc-Fault Circuit-Interrupters, Underwriters Laboratories Inc., Feb 26, 1999, pp. 27-50.

  24. Gordon, Ted, “Fire Protection Features of GFCIs”, ASHI Technical Journal, U.S. Consumer Product Safety Commission, Spring 1993.

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lee, D.A., Trotta, A.M. & King, W.H. New Technology for Preventing Residential Electrical Fires: Arc-Fault Circuit Interrupters (AFCIs). Fire Technology 36, 145–162 (2000). https://doi.org/10.1023/A:1015410726786

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1015410726786

Keywords

Navigation