A 15-yr-old female (who consented to this report) underwent a major colorectal operation. A lumbar epidural catheter was placed preoperatively but yielded inadequate postoperative analgesia in spite of manipulations of catheter position. It was removed, and on the following day a second epidural catheter was placed in the T11–12 interspace. No paresthesia occurred and aspiration was negative for cerebrospinal fluid and blood. Because of the difficulty with the previous epidural, 3 mL of non-ionic contrast was injected through the catheter to verify correct placement. Anterior–posterior and lateral portable chest x-rays (supine position) were obtained immediately after injection (Figure). The radiocontrast is seen in a dense, thin, cephalad column characteristic of subdural injections,1 extending up to the level of the C7–T1 interspace. The x-ray characteristics of intrathecal and epidural injection were not evident. Intrathecally injected non-ionic contrast, which is miscible in cerebrospinal fluid, disperses rapidly. With sufficient volume, the thecal sac fills homogeneously with contrast and the typical myelographic appearance becomes evident. Epidural injection yields local spread, in particular in the direction of the intervertebral foramina along the exiting nerve root sheaths, resulting in a dispersed, feathery, “Christmas-tree-like” pattern.2 The present injection yielded the sharply delineated pattern that is characteristic of subdural injections.1 The catheter was removed without additional injections.

The subdural space is a potential space between the dura and the immediately subjacent pia-arachnoid mater.3 The possibility for injections into this space is reasonably well known to anesthesiologists as an explanation for incomplete blocks and unusual distributions of anesthetic effect.4 Most prior radiologic demonstrations of the subdural space have entailed lumbar injections of larger volumes of radiocontrast with greater lateral spread and more limited vertical distribution.1 These present images show the potential for remarkably wide distribution of a small volume of injectate, and therefore of anesthetic effect, when subdural injection occurs at thoracic levels. It is possible that more extensive spread will sometimes occur because the spinal canal is narrower in the thoracic region.

Figure
figure 1

Anterior–posterior (left) and lateral (right) radiographs taken immediately after injection of 3 mL of radiocontrast through an epidural catheter placed at the T11–12 interspace. An extensive vertical column of radiocontrast is evident in the subdural space. Horizontal arrows indicate the radiocontrast column. Diagonal arrows indicate the tip of the epidural catheter