Abstract
An autopsy involves examination of a body using invasive methods such as dissection, and includes various tests using samples procured during dissection. During medicolegal autopsies, the blood carboxyhemoglobin concentration is commonly measured using the AVOXimeter® 4000 as a point-of-care test. When evaluating the body following hypovolemic shock, characteristics such as reduced livor mortis or an anemic appearance of the viscera can be identified, but these observations arequite subjective. Thus, a more objective test is required for the postmortem diagnosis of anemia. In the present study, the AVOXimeter® 4000 was used to investigate the utility of point-of-care hemoglobin testing. Hemoglobin tests were performed in 93 autopsy cases. The AVOXimeter® 4000 and the BC-2800 Auto Hematology Analyzer were used to test identical samples in 29 of these cases. The results of hemoglobin tests performed with these two devices were statistically similar (r = 0.969). The results of hemoglobin tests using postmortem blood were compared with antemortem test results from medical records from 31 cases, and these results were similar. In 13 of 17 cases of death from internal hemorrhage, hemoglobin levels were lower in the cardiac blood than in blood from the affected body cavity, likely due to compensatory changes induced by antemortem hemorrhage. It is concluded that blood hemoglobin testing may be useful as a point-of-care test for diagnosing postmortem anemia.
Similar content being viewed by others
References
Palmiere C, Mangin P. Postmortem chemistry update part I. Int J Legal Med. 2012;126:187–98.
Palmiere C, Mangin P. Postmortem chemistry update part II. Int J Legal Med. 2012;126:199–215.
Fujihara J, Kinoshita H, Tanaka N, et al. Accuracy and usefulness of the AVOXimeter 4000 as routine analysis of carboxyhemoglobin. J Forensic Sci. 2013;58:1047–9.
Gutierrez G, Reines HD, Wulf-Gutierrez ME. Clinical review: hemorrhagic shock. Crit Care. 2004;8:373–81.
Ishida M, Gonoi W, Hagiwara K, et al. Hypostasis in the heart and great vessels of non-traumatic in-hospital death cases on postmortem computed tomography: relationship to antemortem blood tests. Legal Med (Tokyo). 2011;13:280–5.
Funding
This work was supported by the National Forensic Service (NFS2017MED01), Ministry of Interior, Republic of Korea.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
This study used medicolegal autopsies requested by the public prosecutor with Court approval. The author and institute that approved this study judged this study to be exempt from IRB approval.
Conflict of interest
No potential conflict of interest relevant to this article was reported.
Human participants and animal studies
This article does not contain any studies with human participants or animals performed by the authors.
Rights and permissions
About this article
Cite this article
Na, JY., Park, J.H., Choi, B.H. et al. Point-of-care hemoglobin testing for postmortem diagnosis of anemia. Forensic Sci Med Pathol 14, 57–61 (2018). https://doi.org/10.1007/s12024-018-9945-2
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12024-018-9945-2