Abstract
To evaluate the diagnostic accuracy of aortic valve area (AVA) assessment with 320-detector Computed Tomography (MDCT) compared to transthoracic echocardiography (TTE) in a population with mild to severe aortic valve stenosis. AVA was estimated in 169 patients by planimetry on MDCT images (AVAMDCT) and by the continuity equation with TTE (AVATTE). To generate a reference AVA (AVAREF) we used the stroke volume from MDCT divided by the velocity time integral from CW Doppler by TTE (according to the continuity equation: stroke volume in LVOT = stroke volume passing the aortic valve). AVAREF was used as the reference to compare both measures against, since it bypasses the assumption of LVOT being circular in the continuity equation and the potential placement error of PW Doppler in the LVOT. The mean (±SD) age of the patients was 71 (±9) years, 113 (67 %) were males. Mean AVATTE was 0.93 (±0.33) cm2, mean AVAMDCT was 0.99 (±0.36) cm2 and mean AVAREF was 1.00 (±0.39) cm2. The mean difference between AVATTE and AVAMDCT was −0.06 cm2, p = 0.001, mean difference between AVATTE and AVAREF was −0.06 cm2, p < 0.001, and mean difference between AVAMDCT and AVAREF was −0.01 cm2, p = 0.60. Calcification of the aortic valve quantified by Agatston score, significantly decreased the correlation between AVAMDCT and AVAREF, (r low Agatston = 0.90, r high Agatston = 0.57). MDCT measured AVA is slightly larger than AVA measured by TTE (0.06 cm2). The accuracy and precision errors on AVA measurements are comparable for MDCT and TTE. Valvular calcification may primarily affect the accuracy of AVAMDCT.
Similar content being viewed by others
Abbreviations
- TTE:
-
Transthoracic echocardiography
- MDCT:
-
Multi-detector computed tomography
- TAVI:
-
Transcatheter aortic valve implantation
- AVA:
-
Aortic valve area
- Bpm:
-
Beats per minute
- LVOT:
-
Left ventricular outflow tract
- SV:
-
Stroke volume
- VTI:
-
Velocity time integral
- LOA:
-
Limits of agreement
References
Vahanian A, Alfieri O, Andreotti F, Antunes MJ, Baron-Esquivias G, Baumgartner H et al (2012) Guidelines on the management of valvular heart disease (version 2012): The Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS). Eur J Cardiothorac Surg 33:2451–2496
Leipsic J, Gurvitch R, Labounty TM, Min JK, Wood D, Johnson M et al (2011) Multidetector computed tomography in transcatheter aortic valve implantation. JACC Cardiovasc Imaging 4(4):416–429
Feuchtner GM, Dichtl W, Friedrich GJ, Frick M, Alber H, Schachner T et al (2006) Multislice computed tomography for detection of patients with aortic valve stenosis and quantification of severity. J Am Coll Cardiol 47(7):1410–1417
Alkadhi H, Wildermuth S, Plass A, Bettex D, Baumert B, Leschka S et al (2006) Aortic stenosis: comparative evaluation of 16-detector row CT and echocardiography. Radiology 240(1):47–55
Pouleur AC, le Polain de Waroux JB, Pasquet A, Vanoverschelde JL, Gerber BL (2007) Aortic valve area assessment: multidetector CT compared with cine MR imaging and transthoracic and transesophageal echocardiography. Radiology 244(3):745–754
Laissy JP, Messika-Zeitoun D, Serfaty JM, Sebban V, Schouman-Claeys E, Iung B et al (2007) Comprehensive evaluation of preoperative patients with aortic valve stenosis: usefulness of cardiac multidetector computed tomography. Heart 93(9):1121–1125
Feuchtner GM, Muller S, Bonatti J, Schachner T, Velik-Salchner C, Pachinger O et al (2007) Sixty-four slice CT evaluation of aortic stenosis using planimetry of the aortic valve area. AJR Am J Roentgenol 189(1):197–203
Tanaka H, Shimada K, Yoshida K, Jissho S, Yoshikawa J, Yoshiyama M (2007) The simultaneous assessment of aortic valve area and coronary artery stenosis using 16-slice multidetector-row computed tomography in patients with aortic stenosis comparison with echocardiography. Circ J 71(10):1593–1598
Lembcke A, Thiele H, Lachnitt A, Enzweiler CN, Wagner M, Hein PA et al (2008) Precision of forty slice spiral computed tomography for quantifying aortic valve stenosis: comparison with echocardiography and validation against cardiac catheterization. Invest Radiol 43(10):719–728
LaBounty TM, Sundaram B, Agarwal P, Armstrong WA, Kazerooni EA, Yamada E (2008) Aortic valve area on 64-MDCT correlates with transesophageal echocardiography in aortic stenosis. AJR Am J Roentgenol 191(6):1652–1658
Lembcke A, Kivelitz DE, Borges AC, Lachnitt A, Hein PA, Dohmen PM et al (2009) Quantification of aortic valve stenosis: head-to-head comparison of 64-slice spiral computed tomography with transesophageal and transthoracic echocardiography and cardiac catheterization. Invest Radiol 44(1):7–14
Halpern EJ, Mallya R, Sewell M, Shulman M, Zwas DR (2009) Differences in aortic valve area measured with CT planimetry and echocardiography (continuity equation) are related to divergent estimates of left ventricular outflow tract area. AJR Am J Roentgenol 192(6):1668–1673
Westermann Y, Geigenmuller A, Elgeti T, Wagner M, Dushe S, Borges AC et al (2011) Planimetry of the aortic valve orifice area: comparison of multislice spiral computed tomography and magnetic resonance imaging. Eur J Radiol 77(3):426–435
Mizia-Stec K, Pysz P, Jasinski M, Adamczyk T, Drzewiecka-Gerber A, Chmiel A et al (2012) Preoperative quantification of aortic valve stenosis: comparison of 64-slice computed tomography with transesophageal and transthoracic echocardiography and size of implanted prosthesis. Int J Cardiovasc Imaging 28(2):343–352
Bouvier E, Logeart D, Sablayrolles JL, Feignoux J, Scheuble C, Touche T et al (2006) Diagnosis of aortic valvular stenosis by multislice cardiac computed tomography. Eur Heart J 27(24):3033–3038
Lembcke A, Woinke M, Borges AC, Dohmen PM, Lachnitt A, Westermann Y et al (2009) Grading of aortic valve stenosis at 64-slice spiral computed tomography: comparison with transthoracic echocardiography and calibration against cardiac catheterization. Invest Radiol 44(6):360–368
Utsunomiya H, Yamamoto H, Horiguchi J, Kunita E, Okada T, Yamazato R et al (2012) Underestimation of aortic valve area in calcified aortic valve disease: effects of left ventricular outflow tract ellipticity. Int J Cardiol 157(3):347–353
Fuchs A, Kuhl JT, Lonborg J, Engstrom T, Vejlstrup N, Kober L et al (2012) Automated assessment of heart chamber volumes and function in patients with previous myocardial infarction using multidetector computed tomography. J Cardiovasc Comput Tomogr 6(5):325–334
Baumgartner H, Hung J, Bermejo J, Chambers JB, Evangelista A, Griffin BP et al (2009) Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice. J Am Soc Echocardiogr 22(1):1–23
Doddamani S, Grushko MJ, Makaryus AN, Jain VR, Bello R, Friedman MA et al (2009) Demonstration of left ventricular outflow tract eccentricity by 64-slice multi-detector CT. Int J Cardiovasc Imaging 25(2):175–181
Small GR, Kazmi M, Dekemp RA, Chow BJ (2011) Established and emerging dose reduction methods in cardiac computed tomography. J Nucl Cardiol 18(4):570–579
Leipsic J, Labounty TM, Heilbron B, Min JK, Mancini GB, Lin FY et al (2010) Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography. AJR Am J Roentgenol 195(3):649–654
Abdulla J, Sivertsen J, Kofoed KF, Alkadhi H, LaBounty T, Abildstrom SZ et al (2009) Evaluation of aortic valve stenosis by cardiac multislice computed tomography compared with echocardiography: a systematic review and meta-analysis. J Heart Valve Dis 18(6):634–643
Shah RG, Novaro GM, Blandon RJ, Whiteman MS, Asher CR, Kirsch J (2009) Aortic valve area: meta-analysis of diagnostic performance of multi-detector computed tomography for aortic valve area measurements as compared to transthoracic echocardiography. Int J Cardiovasc Imaging 25(6):601–609
Messika-Zeitoun D, Aubry MC, Detaint D, Bielak LF, Peyser PA, Sheedy PF et al (2004) Evaluation and clinical implications of aortic valve calcification measured by electron-beam computed tomography. Circulation 110(3):356–362
Koos R, Mahnken AH, Sinha AM, Wildberger JE, Hoffmann R, Kuhl HP (2004) Aortic valve calcification as a marker for aortic stenosis severity: assessment on 16-MDCT. AJR Am J Roentgenol 183(6):1813–1818
Cowell SJ, Newby DE, Burton J, White A, Northridge DB, Boon NA et al (2003) Aortic valve calcification on computed tomography predicts the severity of aortic stenosis. Clin Radiol 58(9):712–716
Baumgartner H (2006) Hemodynamic assessment of aortic stenosis: are there still lessons to learn? J Am Coll Cardiol 47(1):138–140
Acknowledgments
This work was supported by The Danish Heart Association, Tove and John Girotti’s Fond, and the A.P Møller and wife Chastine McKinney Møllers Foundation, Denmark.
Conflict of interest
Dr. Kofoed has received lecture fees from the Toshiba Medical Systems Corporation.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Larsen, L.H., Kofoed, K.F., Carstensen, H.G. et al. Aortic valve area assessed with 320-detector computed tomography: comparison with transthoracic echocardiography. Int J Cardiovasc Imaging 30, 165–173 (2014). https://doi.org/10.1007/s10554-013-0295-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10554-013-0295-6