Abstract
Introduction
This study aimed to assess acceptability and preferences for the SILCS diaphragm for vaginal gel delivery compared to a prefilled applicator.
Methods
A randomized crossover study among 115 women in South Africa, using both methods during five sex acts.
Results
We found no significant differences in acceptability between the two products. Experience of gel leakage after sex was greater when inserted via applicator. More women were interested in SILCS/gel for multipurpose protection (68%) than in either SILCS alone (17%) or microbicide gel alone (14%).
Conclusions
A SILCS gel delivery system for multipurpose prevention seems feasible and acceptable.
References
Coffey PS, Kilbourne-Brook M, Beksinska M, Thongkrajai E. Short-term acceptability of a single-size diaphragm among couples in South Africa and Thailand. J Fam Plan Reprod Health Care. 2008;34:233–6. doi:10.1783/147118908786000569.
Schwartz J, Weiner D, Lai JJ, Frezieres RG, Creinin MD, Archer DF, et al. Contraceptive efficacy, safety and acceptability of SILCS, a novel single-sized diaphragm used with contraceptive gel. Contraception. 2012;85:327. doi:10.1016/j.contraception.2011.11.060.
van der Straten A, Sahin-Hodoglugil N, Clouse K, Mtetwa S, Chirenje MZ. Feasibility and potential acceptability of three cervical barriers among vulnerable young women in Zimbabwe. J Fam Plan Reprod Health Care. 2010;36:13–9. doi:10.1783/147118910790290966.
Karim SA, Baxter C, Frohlich J, Karim QA. The need for multipurpose prevention technologies in sub-Saharan Africa. BJOG. 2014;121:27–34. doi:10.1111/1471-0528.12842.
Behets FM, Turner AN, Van Damme K, Rabenja NL, Ravelomanana N, Swezey TA, et al. Vaginal microbicide and diaphragm use for sexually transmitted infection prevention: a randomized acceptability and feasibility study among high-risk women in Madagascar. Sex Transm Dis. 2008;35:818–26. doi:10.1097/OLQ.0b013e318175d8ab.
Van der Straten A, Kana MS, Posner SF, Kamba M, Chipato T, Padian NS. Predictors of diaphragm use as a potential sexually transmitted disease/HIV prevention method in Zimbabwe. Sex Transm Dis. 2005;32:64–71. doi:10.1097/01.olq.0000148301.90343.3a.
Sahin-Hodoglugil NN, Montgomery E, Kacanek D, Morar N, Mtetwa S, Nkala B, et al. User experiences and acceptability attributes of the diaphragm and lubricant gel in an HIV prevention trial in southern Africa. AIDS Care. 2011;23:1026–34. doi:10.1080/09540121.2010.543879.
Frezieres RG, Walsh T, Kilbourne-Brook M, Coffey PS. Couples’ acceptability of the SILCS diaphragm for microbicide delivery. Contraception. 2012;85:99–107. doi:10.1016/j.contraception.2011.04.003.
Pentlicky S, Rosen M, Coffey PS, Kilbourne-Brook M, Shaunik A, Schreiber CA, et al. An exploratory, randomized, crossover MRI study of microbicide delivery with the SILCS diaphragm compared to a vaginal applicator. Contraception. 2013;87:187–92. doi:10.1016/j.contraception.2012.06.016.
Press release: HIV prevention study does not confirm tenofovir gel effectiveness [Internet]. New York: AVAC: Global Advocacy for HIV Prevention; 2015 [cited 2016 Mar 7]. http://www.avac.org/sites/default/files/u3/FACTSfeb24.pdf.
Quaife M, Cabrera M, Eakle R, Vickerman P, Delany-Moretlwe S, Terris-Prestholt F. One size will not fit all: divergent stated preferences for new antiretroviral-based HIV prevention products across adults, adolescents and female sex workers in South Africa. EUHEA Conference: Hamburg, Germany; July 13–16, 2016. Session ESA Ost 221.
van der Straten A, Stadler J, Montgomery E, Hartmann M, Magazi B, Mathebula F, et al. Women’s experiences with oral and vaginal pre-exposure prophylaxis: the VOICE-C qualitative study in Johannesburg, South Africa. PLoS ONE. 2014;9:e89118. doi:10.1371/journal.pone.0089118.
Acknowledgements
We would like to thank the women and men from Commercial City Clinic who generously shared their time and views to make this research possible, and Commercial City Clinic staff for providing support for the research activities. The authors would like to thank Jennifer Foster, Clinical Coordinator at PATH, for assistance in developing and coordinating this study. This project was made possible by the generous support of the American people through the United States Agency for International Development (USAID) under the terms of HealthTech Cooperative Agreement #AID-OAA-A-11-00051. The contents are the responsibility of PATH and the MatCH Research Unit and do not necessarily reflect the views of USAID or the US government.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare they have no conflict of interest.
Ethical Approval
All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.
Rights and permissions
About this article
Cite this article
Beksinska, M., Greener, R., Smit, J. et al. A Randomized Crossover Study Evaluating the Use and Acceptability of the SILCS Diaphragm Compared to Vaginal Applicators for Vaginal Gel Delivery. AIDS Behav 22, 127–132 (2018). https://doi.org/10.1007/s10461-017-1913-4
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10461-017-1913-4