Skip to main content
Log in

Usefulness of three-dimensional transesophageal echocardiography for diagnosis of hemolytic anemia due to inverted internal felt strip after surgery for aortic dissection

  • Case Report
  • Published:
Journal of Medical Ultrasonics Aims and scope Submit manuscript

Abstract

Felt strips are widely used for reinforcement of the aortic stump in surgery for aortic dissection (AD). Postoperative hemolytic anemia (HA) due to an inverted internal felt strip at the aortic stump fixation for AD is extremely rare. A 70-year-old woman underwent ascending aorta replacement for acute type A AD, where both proximal and distal anastomotic sites were reinforced with Teflon felt strips. A week later, macroscopic hematuria and HA emerged. Three-dimensional transesophageal echocardiography (3D-TEE) demonstrated that the proximal inner felt strip turned up and protruded into the aortic inner lumen. At redo surgery, which was performed 2 weeks after the initial surgery, the findings of 3D-TEE were confirmed, and the inverted internal felt strip was replaced with a bovine pericardial strip. The findings of HA disappeared immediately after the second surgery. 3D-TEE is a very informative, valuable modality for accurate diagnosis that leads to a safe surgery.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Sekine Y, Yamamoto S, Fujikawa T, et al. Haemolytic anaemia resulting from the surgical repair of acute type A aortic dissection. Interact Cardiovasc Surg. 2014;18:230–3.

    Article  Google Scholar 

  2. Nakamura Y, Ogino H, Matsuda H, et al. Hemolytic anemia after operation for aortic dissection using Teflon felt strips. Ann Thorac Surg. 2008;85:1784–7.

    Article  PubMed  Google Scholar 

  3. Shiga T, Wajima Z, Apfel CC, et al. Diagnostic accuracy of transesophageal echocardiography, helical computed tomography, and magnetic resonance imaging for suspected thoracic aortic dissection. Arch Intern Med. 2006;166:1350–6.

    Article  PubMed  Google Scholar 

  4. Scohy TV, Geniets B, McGhie J, et al. Feasibility of real-time three-dimensional transesophageal echocardiography in type A aortic dissection. Interact Cardiovasc Thorac Surg. 2010;11:112–3.

    Article  PubMed  Google Scholar 

  5. Hata M, Yoshitake I, Wakui S, et al. Postoperative early hemolytic anemia due to inverted teflon felt strip after emergency repair for type A dissection. Thorac Cardiovasc Surg. 2012;60:482–4.

    Article  CAS  PubMed  Google Scholar 

  6. Kang H, Choe JW, Cho DY, et al. Hemolytic anemia case caused by an inverted inner felt after Bentall operation. J Korean Med Sci. 2013;28:1827–9.

    Article  PubMed  PubMed Central  Google Scholar 

  7. Floten HS, Ravichandran PS, Furnary AP, et al. Adventitial inversion technique in repair of aortic dissection. Ann Thorac Surg. 1995;59:771–2.

    Article  CAS  PubMed  Google Scholar 

Download references

Acknowledgements

The authors are grateful to Yoko Motomura for her assistance in manuscript preparation.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Takeshi Oda.

Ethics declarations

Conflict of interest

None declared.

Ethical statements

Additional informed consent was obtained from the patient for whom identifying information is included in this article.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Oda, T., Yasunaga, H., Zaima, Y. et al. Usefulness of three-dimensional transesophageal echocardiography for diagnosis of hemolytic anemia due to inverted internal felt strip after surgery for aortic dissection. J Med Ultrasonics 44, 211–214 (2017). https://doi.org/10.1007/s10396-016-0759-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10396-016-0759-0

Keywords

Navigation