Abstract
The purpose of this study was to clarify the stability of masticatory movement after placement of implant-supported denture. Fourteen patients (patient group) with mandibular implants denture and maxillary complete denture and 30 dentate adults (control group) were asked to chew a boiled fishpaste, and the masticatory movement was recorded using MKG. For the 10 cycles beginning with the 5th cycle of mastication, the parameters representing the stability of masticatory movement were calculated. Data collected at 1, 3, 6, 9 months and 1, 2, 3 years after insertion of implants denture were compared between sessions and also between the patient and control groups. The mean and standard deviation of the values in the patient group at 1 month after insertion of implants denture were large, but gradually decreased 6 to 9 months after insertion of implants denture. Each parameter maintained almost the same value from 1 to 3 years. The parameter values of the patient group were significantly larger than those of control group from 1 to 9 months after insertion of implants denture, but 1 year after insertion of implants denture, there was no significant difference between the two groups in 5 out of 7 parameters. From these results, it was suggested that a certain duration, about 9 months to 1 year, was necessary for patients with implants denture to adapt to the new masticatory function and that the timing of functional evaluation should be set to 1 year after insertion of implants denture.
Similar content being viewed by others
References
Sato S, Nasu F, Motegi K. Analysis of kinesiograph recordings and masticatory efficiency after treatment of non-reducing disk displacement of the temporomandibular joint. J Oral Rehabil. 2003;30:708–13.
Rilo B, da Silva JL, Mora MJ, Cadarso-Suárez C, Santana U. Unilateral posterior crossbite and mastication. Arch Oral Biol. 2007;52:474–8.
Takeda H, Nakamura Y, Handa H, Ishii H, Hamada Y, Seto K. Examination of masticatory movement and rhythm before and after surgical orthodontics in skeletal class III patients with unilateral posterior cross-bite. J Oral Maxillofac Surg. 2009;67:1844–9.
Piancino MG, Frongia G, Dalessandri D, Bracco P, Ramieri G. Reverse cycle chewing before and after orthodontic-surgical correction in class III patients. Oral Surg Oral Med Oral Pathol Oral Radiol. 2013;115:328–31.
Lund JP. Mastication and its control by the brain stem. Crit Rev Oral Biol Med. 1991;2:33–64.
Trulsson M, Johansson RS. Encoding of tooth loads by human periodontal afferents and their role in jaw motor control. Prog Neurobiol. 1996;49:267–84.
van der Bilt A, Engelen L, Pereira LJ, van der Glas HW, Abbink JH. Oral physiology and mastication. Physiol Behav. 2006;89:22–7.
Trulsson M. Sensory–motor function of human periodontal mechanoreceptors. J Oral Rehabil. 2006;33:262–73.
Shiga H, Stohler CS, Kobayashi Y. The effect of bolus size on the chewing cycle in humans. Odontology. 2001;89:49–53.
Sun X, Zhai JJ, Liao J, Teng MH, Tian A, Liang X. Masticatory efficiency and oral health-related quality of life with implant-retained mandibular overdentures. Saudi Med J. 2014;35:1195–202.
Ishida K, Nogawa T, Takayama Y, Saito M, Yokoyama A. Does neuroticism influence oral health-related QOL in patients with removable partial dentures? JDR Clin Trans Res. 2017;2:370–5.
Yamamoto S, Shiga H. Masticatory performance and oral health-related quality of life before and after complete denture treatment. J Prosthodont Res. 2018;62:370–4.
Heckmann SM, Heussinger S, Linke JJ, Graef F, Pröschel P. Improvement and long-term stability of neuromuscular adaptation in implant-supported overdentures. Clin Oral Implants Res. 2009;20:1200–5.
Toman M, Toksavul S, Saracoglu A, Cura C, Hatipoglu A. Masticatory performance and mandibular movement patterns of patients with natural dentitions, complete dentures, and implant-supported overdentures. Int J Prosthodont. 2012;25:135–7.
Amaral CFD, Souza GA, Pinheiro MA, Campos CH, Garcia RCMR. Sensorial ability, mastication and nutrition of single-implant overdentures wearers. Braz Dent J. 2019;30:66–72.
Kuramochi A, Shiga H. Effect of denture treatment on masticatory movement in patients with complete dentures. J Prosthodont Res. 2019;63:245–9.
Spitzl C, Pröschel P, Wichmann M, Heckmann S. Long-term neuromuscular status in overdenture and complete denture patients with severe mandibular atrophy. Int J Oral Maxillofac Implants. 2012;27:155–61.
Veyrune JL, Opé S, Nicolas E, Woda A, Hennequin M. Changes in mastication after an immediate loading implantation with complete fixed rehabilitation. Clin Oral Investig. 2013;17:1127–34.
Gonçalves TM, Campos CH, Garcia RCR. Mastication and jaw motion of partially edentulous patients are affected by different implant-based prostheses. J Oral Rehabil. 2014;41:507–14.
Suzuki Y, Kono K, Shimpo H, Sato Y, Ohkubo C. Clinical evaluation of implant-supported removable partial dentures with a stress-breaking attachment. Implant Dent. 2017;26:516–23.
Panek H, Krawczykowska H, Dobosz A, Napadłek P, Panek BA, Sosna-Gramza M. Follow-up visits as a measure of adaptation process to removable prostheses. Gerodontology. 2006;23:87–92.
Eberhard L, Oh K, Eiffler C, Rammelsberg P, Kappel S, Schindler HJ, Giannakopoulos NN. Adaptation to new complete dentures-is the neuromuscular system outcome-oriented or effort-oriented? Clin Oral Investig. 2018;22:2309–17.
Inaba J, Shiga H, Kobayashi Y. Peripheral feedback adjustment in chewing various types of food. J Jpn Prosthodont Soc. 2001;45:271–82.
Vieira RA, Melo AC, Budel LA, Gama JC, de Mattias Sartori IA, Thomé G. Benefits of rehabilitation with implants in masticatory function: is patient perception of change in accordance with the real improvement? J Oral Implantol. 2014;40:263–9.
Meena A, Jain V, Singh N, Arora N, Jha R. Effect of implant-supported prosthesis on the bite force and masticatory efficiency in subjects with shortened dental arches. J Oral Rehabil. 2014;41:87–92.
Uesugi H, Shiga H. Relationship between masticatory performance using a gummy jelly and masticatory movement. J Prosthodont Res. 2017;61:419–25.
Trulsson M, Gunne HS. Food-holding and -biting behavior in human subjects lacking periodontal receptors. J Dent Res. 1998;77:574–82.
Grigoriadis A, Johansson RS, Trulsson M. Adaptability of mastication in people with implant-supported bridges. J Clin Periodontol. 2011;38:395–404.
Funding
The authors received no support from any grant.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Shiga, H., Ogura, S., Hiraga, Y. et al. Stability of masticatory movements after placement of implant-supported denture. Odontology 110, 216–222 (2022). https://doi.org/10.1007/s10266-021-00646-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10266-021-00646-9