L’utilisation du bistouri électrique en gastroentérologie chez les patients porteurs d’un stimulateur cardiaque ou d’un défibrillateur implantable

Electrosurgery current management in a patient with pacemaker or implantable defibrillator during gastroenterology procedure

  • Videodigest
  • Published:
Acta Endoscopica

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Références

  1. Niehaus M, Tebbenjohanns J. Electromagnetic interference in patients with implanted pace makers or cardioverter-defibrillators. Heart 2001;86:246–8

    CAS  PubMed  PubMed Central  Google Scholar 

  2. Bayes J. A survey of ophtalmic anesthesists on managing pacemakers and implanted cardiac defibrillators. Anesth Analg 2010; 103:1615–6

    Article  Google Scholar 

  3. Crossley GH, Poole JE, Rozner MA, et al. The HRS/ASA expert consensus statement on the perioperative management of patients with implantable defibrillators, pacemakers and arythmia monitors: facilities and patient management: executive summary. Heart Rhythm 2011;8:1114–54

    Article  PubMed  Google Scholar 

  4. Snow JS, Kalenderian D, Colasacco JA, et al. Implanted devices and electromagnetic interference: case presentations and review. J Invasive Cardiol 1995;7:25–32

    CAS  PubMed  Google Scholar 

  5. Katzenberg CA, Marcus FI, Heusinkveld RS, Mammana RB. Pacemaker failure due to radiation therapy. Pacing Clin Electrophysiol 1982;5:156–9

    Article  CAS  PubMed  Google Scholar 

  6. Afssaps. Interactions entre dispositifs médicaux implantables actifs et dispositifs médicaux. 2005

  7. Wilson JH, Lattner S, Jacob R, Stewart R. Electrocautery does not interfere with function of the automatic implantable cardioverter defibrillator. Ann Thorac Surg 1991;51:225–6

    Article  CAS  PubMed  Google Scholar 

  8. Amar D, Fogel DH, Shah JP. The Shaw hemostatic sclapel as an alternative to electrocautery in patients with pacemakers. Anesthesiology 1996;85:223

    Article  CAS  PubMed  Google Scholar 

  9. Boston Scientific. Bistouri électrique et dispositifs implantables. 2008

  10. Erbe. Principes de l’électrochirurgie. 2015

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to V. Quentin.