Modified optical coefficient measurement system for bulk tissue using an optical fiber insertion with varying field of view and depth at the fiber tip

  • Original Article
  • Published:
Lasers in Medical Science Aims and scope Submit manuscript

Abstract

To measure the few millimeter–scale macroscopic optical properties of biological tissue, including the scattering coefficient, while avoiding the instability that originates from sample slicing preparation processes, we performed propagated light intensity measurements through an optical fiber that punctures the bulk tissue while varying the fiber tip depth and the field of view (FOV) at the tip; the results were analyzed using the inverse Monte Carlo method. We realized FOV changes at the fiber tip in the bulk tissue using a variable aperture that was located outside the bulk tissue through a short high-numerical aperture (high-NA) multi-mode fiber with a quasi-straight shape. Using a homogeneous optical model solution, we verified the principle and operation of the constructed experimental system. A 200-μm-core-diameter silica fiber with NA of 0.5 and length of 1 m installed in a 21G needle was used. The detection fiber’s shape was maintained over a radius of curvature of 30 cm. The dependences of the detected light intensity on the FOV and the depth showed better than 1.4% accuracy versus calculated dependences based on the measured optical properties of the solution. Adaptation of the method for use with complex structured biological tissue, particularly in the presence of a thick fascia, was not completely resolved. However, we believe that our specific fiber puncture–based measurement method for use in bulk tissue based on variation of the FOV with inverse Monte Carlo method-based analysis will be useful in obtaining optical coefficients while avoiding sample preparation–related instabilities.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

Similar content being viewed by others

References

  1. Flock ST et al (1989) Monte Carlo modeling of light propagation in highly scattering tissues. I. Model predictions and comparison with diffusion theory. IEEE Trans Biomed Eng 36(12):1162–1168

    Article  CAS  PubMed  Google Scholar 

  2. Ritz JP et al (2001) Optical properties of native and coagulated porcine liver tissue between 400 and 2400 nm. Lasers Surg Med 29(3):205–212

    Article  CAS  PubMed  Google Scholar 

  3. Roggan A et al (1999) Optical properties of circulating human blood in the wavelength range 400–2500 nm. J Biomed Opt 4(1):36–47

    Article  CAS  PubMed  Google Scholar 

  4. Hammer M et al (1995) Optical properties of ocular fundus tissues – an in vitro study using the double-integrating-sphere technique and inverse Monte Carlo simulation. Phys Med Biol 40(6):963–978

    Article  CAS  PubMed  Google Scholar 

  5. Pickering JW et al (1993) Double-integrating-sphere system for measuring the optical properties of tissue. Appl Opt 32(4):399–410

    Article  CAS  PubMed  Google Scholar 

  6. Beek JF et al (1997) In vitro double-integrating-sphere optical properties of tissues between 630 and 1064 nm. Phys Med Bio 42(11):2255–2261

    Article  CAS  Google Scholar 

  7. Derbyshire GJ et al (1990) Thermally induced optical property changes in myocardium at 1.06 μm. Lasers Surg Med 10(1):28–34

    Article  CAS  PubMed  Google Scholar 

  8. Splinter R et al (1991) Optical properties of normal, diseased, and laser photocoagulated myocardium at the Nd: YAG wavelength. Lasers Surg Med 11(2):117–124

    Article  CAS  PubMed  Google Scholar 

  9. Pickering JW et al (1993) Changes in the optical properties (at 632.8 nm) of slowly heated myocardium. Appl Opt 32(4):367–371

    Article  CAS  PubMed  Google Scholar 

  10. Jacques SL (2013) Optical properties of biological tissues: a review. Phys Med Biol 58(11):R37–R61

    Article  PubMed  Google Scholar 

  11. Graaff R et al (1993) Optical properties of human dermis in vitro and in vivo. Appl Opt 32(4):435–447

    Article  CAS  PubMed  Google Scholar 

  12. Wilson BC et al (1987) Indirect versus direct techniques for the measurement of the optical properties of tissues. Photochem Photobiol 46(5):601–608

    Article  CAS  PubMed  Google Scholar 

  13. Muragaki Y et al (2013) Phase II clinical study on intraoperative photodynamic therapy with talaporfin sodium and semiconductor laser in patients with malignant brain tumors. J Neurosurg 119(4):845–852

    Article  CAS  Google Scholar 

  14. Prahl SA et al (1993) Determining the optical properties of turbid media by using the adding–doubling method. Appl Opt 32(4):559–568

    Article  CAS  PubMed  Google Scholar 

  15. Cheong WF et al (1990) A review of the optical properties of biological tissues. IEEE J Quantum Electron 26(12):2166–2185

    Article  Google Scholar 

  16. Toublanc D (1996) Henyey–Greenstein and Mie phase functions in Monte Carlo radiative transfer computations. Appl Opt 35(18):3270–3274

    Article  CAS  PubMed  Google Scholar 

  17. Taylor H (1984) Bending effects in optical fibers. J Lightwave Technol 2(5):617–628

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Haruna Nakazawa.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical approval

This article does not contain any studies with human participants or animals performed by any of the authors.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Nakazawa, H., Doi, M., Ogawa, E. et al. Modified optical coefficient measurement system for bulk tissue using an optical fiber insertion with varying field of view and depth at the fiber tip. Lasers Med Sci 34, 1613–1618 (2019). https://doi.org/10.1007/s10103-019-02756-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10103-019-02756-x

Keywords

Navigation