Objectives

The objective of this clinical study was to compare and assess the clinical performance of tooth-supported and implant-supported zirconia single crowns with sintered veneering caps.

Methods

In this prospective study, 118 patients with a total of 220 single crowns placed on 106 teeth (69 vital teeth, 37 endodontically treated teeth) and 114 implants in molar and premolar regions were examined during a mean observation period of 42 months. The restorations were evaluated for technical failures such as veneering porcelain fractures (chipping), surface quality, marginal fit, and the interface quality of the coping and sintered veneering. The soft tissue status was assessed using the modified Silness and Löe’s plaque and gingival index (mPI) and the modified Muhlemann sulcus bleeding index (mSBI). Tooth-supported crowns were checked for secondary caries and hypersensitivity during the follow-up period. Recalls were performed every 6 months.

Results

The 3-year Kaplan-Meier success probability was 98.2% and 100% for implant- and tooth-supported crowns, respectively. A significant difference could be detected between the implant-supported and tooth-supported zirconia single crowns, in terms of their chipping rate (p = 0.039). Veneering material fractures were recorded on two implant-supported restorations (1.8%). No veneering fractures occurred on tooth-supported single crowns. The plaque and gingival index and sulcus bleeding index showed stable and healthy soft peri-implant and periodontal tissues. Neither loss of vitality nor secondary caries occurred on tooth-supported crowns.

Conclusions

Zirconia-based single crowns with a sintered veneering cap showed promising clinical results on both tooth and implant abutments; however, the dental implants were more prone to complications. In terms of clinical significance, high-strength ceramic with a sintered veneering cap can be recommended for prosthetic treatment of both tooth- and implant-supported single crowns in molar regions.

Clinical relevance

This study provides valuable information for further application of all-ceramic restorations.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

References

  1. Devaud V (2005) Guidelines for success with zirconia ceramics: the changing standards. Pract Proced Aesthet Dent 17:508–510

    PubMed  Google Scholar 

  2. Bremer F, Grade S, Kohorst P, Stiesch M (2011) In vivo biofilm formation on different dental ceramics. Quintessence Int 42:565–574

    PubMed  Google Scholar 

  3. Holand W, Schweiger M, Frank M, Rheinberger V (2000) A comparison of the microstructure and properties of the IPS Empress 2 and the IPS Empress glass-ceramics. J Biomed Mater Res 53:297–303

    PubMed  Google Scholar 

  4. Conrad HJ, Seong WJ, Pesun IJ (2007) Current ceramic materials and systems with clinical recommendations: a systematic review. J Prosthet Dent 98:389–404

    PubMed  Google Scholar 

  5. Nakamura K, Kanno T, Milleding P, Ortengren U (2010) Zirconia as a dental implant abutment material: a systematic review. Int J Prosthodont 23:299–309

    PubMed  Google Scholar 

  6. Koenig V, Vanheusden AJ, Le Goff SO, Mainjot AK (2013) Clinical risk factors related to failures with zirconia-based restorations: an up to 9-year retrospective study. J Dent 41:1164–11674

    PubMed  Google Scholar 

  7. Luthardt RG, Holzhuter MS, Rudolph H, Herold V, Walter MH (2004) CAD/CAM-machining effects on Y-TZP zirconia. Dent Mater 20:655–662

    PubMed  Google Scholar 

  8. Gherlone E, Mandelli F, Cappare P, Pantaleo G, Traini T, Ferrini F (2014) A 3 years retrospective study of survival for zirconia-based single crowns fabricated from intraoral digital impressions. J Dent 42:1151–1155

    PubMed  Google Scholar 

  9. Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH (2007) Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 20:383–388

    PubMed  Google Scholar 

  10. Larsson C, Vult von Steyern P (2010) Five-year follow-up of implant-supported Y-TZP and ZTA fixed dental prostheses. A randomized, prospective clinical trial comparing two different material systems. Int J Prosthodont 23:555–561

    PubMed  Google Scholar 

  11. Jung RE, Pjetursson BE, Glauser R, Zembic A, Zwahlen M, Lang NP (2008) A systematic review of the 5-year survival and complication rates of implant-supported single crowns. Clin Oral Implants Res 19:119–130

    PubMed  Google Scholar 

  12. Schwarz S, Schroder C, Hassel A, Bomicke W, Rammelsberg P (2012) Survival and chipping of zirconia-based and metal-ceramic implant-supported single crowns. Clin Implant Dent Relat Res 14(Suppl 1):119–125

    Google Scholar 

  13. Aboushelib MN, Kleverlaan CJ, Feilzer AJ (2006) Microtensile bond strength of different components of core veneered all-ceramic restorations. Part II: zirconia veneering ceramics. Dent Mater 22:857–863

    PubMed  Google Scholar 

  14. Heintze SD, Rousson V (2010) Survival of zirconia- and metal-supported fixed dental prostheses: a systematic review. Int J Prosthodont 23:493–502

    PubMed  Google Scholar 

  15. Pelaez J, Cogolludo PG, Serrano B, Serrano JF, Suarez MJ (2012) A four-year prospective clinical evaluation of zirconia and metal-ceramic posterior fixed dental prostheses. Int J Prosthodont 25:451–458

    PubMed  Google Scholar 

  16. Vigolo P, Mutinelli S (2012) Evaluation of zirconium-oxide-based ceramic single-unit posterior fixed dental prostheses (FDPs) generated with two CAD/CAM systems compared to porcelain-fused-to-metal single-unit posterior FDPs: a 5-year clinical prospective study. J Prosthodont 21:265–269

    PubMed  Google Scholar 

  17. Larsson C, Vult von Steyern P, Sunzel B, Nilner K (2006) All-ceramic two- to five-unit implant-supported reconstructions. A randomized, prospective clinical trial. Swed Dent J 30:45–53

    PubMed  Google Scholar 

  18. Rosentritt M, Steiger D, Behr M, Handel G, Kolbeck C (2009) Influence of substructure design and spacer settings on the in vitro performance of molar zirconia crowns. J Dent 37:978–983

    PubMed  Google Scholar 

  19. Swain MV (2009) Unstable cracking (chipping) of veneering porcelain on all-ceramic dental crowns and fixed partial dentures. Acta Biomater 5:1668–1677

    PubMed  Google Scholar 

  20. Schmitter M, Mueller D, Rues S (2012) Chipping behaviour of all-ceramic crowns with zirconia framework and CAD/CAM manufactured veneer. J Dent 40:154–162

    PubMed  Google Scholar 

  21. Schmitter M, Mueller D, Rues S (2013) In vitro chipping behaviour of all-ceramic crowns with a zirconia framework and feldspathic veneering: comparison of CAD/CAM-produced veneer with manually layered veneer. J Oral Rehabil 40:519–525

    PubMed  Google Scholar 

  22. Du Q, Swain MV, Zhao K (2014) Fractographic analysis of anterior bilayered ceramic crowns that failed by veneer chipping. Quintessence Int 45:369–376

    PubMed  Google Scholar 

  23. Broseghini C, Broseghini M, Gracis S, Vigolo P (2014) Aesthetic functional area protection concept for prevention of ceramic chipping with zirconia frameworks. Int J Prosthodont 27:174–176

    PubMed  Google Scholar 

  24. Zhang Z, Guazzato M, Sornsuwan T, Scherrer SS, Rungsiyakull C, Li W, Swain MV, Li Q (2013) Thermally induced fracture for core-veneered dental ceramic structures. Acta Biomater 9:8394–8402

    PubMed  Google Scholar 

  25. Sailer I, Muhlemann S, Zwahlen M, Hammerle CH, Schneider D (2012) Cemented and screw-retained implant reconstructions: a systematic review of the survival and complication rates. Clin Oral Implants Res 23(Suppl 6):163–201

    PubMed  Google Scholar 

  26. Teichmann M, Gockler F, Weber V, Yildirim M, Wolfart S, Edelhoff D (2017) Ten-year survival and complication rates of lithium-disilicate (Empress 2) tooth-supported crowns, implant-supported crowns, and fixed dental prostheses. J Dent 56:65–77

    PubMed  Google Scholar 

  27. Larsson C, Wennerberg A (2014) The clinical success of zirconia-based crowns: a systematic review. Int J Prosthodont 27:33–43

    PubMed  Google Scholar 

  28. Monaco C, Caldari M, Scotti R, ACR Group (2013) Clinical evaluation of 1,132 zirconia-based single crowns: a retrospective cohort study from the AIOP clinical research group. Int J Prosthodont 26:435–442

    PubMed  Google Scholar 

  29. Monaco C, Caldari M, Scotti R, ACR Group (2015) Clinical evaluation of zirconia-based restorations on implants: a retrospective cohort study from the AIOP clinical research group. Int J Prosthodont 28:239–242

    PubMed  Google Scholar 

  30. Klages U, Weber AG, Wehrbein H (2005) Approximal plaque and gingival sulcus bleeding in routine dental care patients: relations to life stress, somatization and depression. J Clin Periodontol 32:575–582

    PubMed  Google Scholar 

  31. Schiffman E, Ohrbach R, Truelove E, Look J, Anderson G, Goulet JP, List T, Svensson P, Gonzalez Y, Lobbezoo F, Michelotti A, Brooks SL, Ceusters W, Drangsholt M, Ettlin D, Gaul C, Goldberg LJ, Haythornthwaite JA, Hollender L, Jensen R, John MT, de Laat A, de Leeuw R, Maixner W, van der Meulen M, Murray GM, Nixdorf DR, Palla S, Petersson A, Pionchon P, Smith B, Visscher CM, Zakrzewska J, Dworkin SF, International RDC/TMD Consortium Network, International association for Dental Research, Orofacial Pain Special Interest Group, International Association for the Study of Pain (2014) Diagnostic Criteria for Temporomandibular Disorders (DC/TMD) for Clinical and Research Applications: recommendations of the International RDC/TMD Consortium Network* and Orofacial Pain Special Interest Group†. J Oral Facial Pain Headache 28:6–27

    PubMed  PubMed Central  Google Scholar 

  32. Happe A, Roling N, Schafer A, Rothamel D (2015) Effects of different polishing protocols on the surface roughness of Y-TZP surfaces used for custom-made implant abutments: a controlled morphologic SEM and profilometric pilot study. J Prosthet Dent 113:440–447

    PubMed  Google Scholar 

  33. Dornbush JR, Reiser GM, Ho DK (2014) Platform switching and abutment emergence profile modification on peri-implant soft tissue. Alpha Omegan 107:28–32

    PubMed  Google Scholar 

  34. Beuer F, Schweiger J, Eichberger M, Kappert HF, Gernet W, Edelhoff D (2009) High-strength CAD/CAM-fabricated veneering material sintered to zirconia copings—a new fabrication mode for all-ceramic restorations. Dent Mater 25:121–128

    PubMed  Google Scholar 

  35. Simeone P, Gracis S (2015) Eleven-year retrospective survival study of 275 veneered lithium disilicate single crowns. Int J Periodontics Restorative Dent 35:685–694

    PubMed  Google Scholar 

  36. Galindo ML, Sendi P, Marinello CP (2011) Estimating long-term survival of densely sintered alumina crowns: a cohort study over 10 years. J Prosthet Dent 106:23–28

    PubMed  Google Scholar 

  37. Rinke S, Tsigaras A, Huels A, Roediger M (2011) An 18-year retrospective evaluation of glass-infiltrated alumina crowns. Quintessence Int 42:625–633

    PubMed  Google Scholar 

  38. Valenti M, Valenti A (2009) Retrospective survival analysis of 261 lithium disilicate crowns in a private general practice. Quintessence Int 40:573–579

    PubMed  Google Scholar 

  39. Sailer I, Makarov NA, Thoma DS, Zwahlen M, Pjetursson BE (2015) All-ceramic or metal-ceramic tooth-supported fixed dental prostheses (FDPs)? A systematic review of the survival and complication rates. Part I: single crowns (SCs). Dent Mater 31:603–623

    PubMed  Google Scholar 

  40. Molin MK, Karlsson SL (2008) Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs. Int J Prosthodont 21:223–227

    PubMed  Google Scholar 

  41. Miyazaki T, Nakamura T, Matsumura H, Ban S, Kobayashi T (2013) Current status of zirconia restoration. J Prosthodont Res 57:236–261

    PubMed  Google Scholar 

  42. Raigrodski AJ, Hillstead MB, Meng GK, Chung KH (2012) Survival and complications of zirconia-based fixed dental prostheses: a systematic review. J Prosthet Dent 107:170–177

    PubMed  Google Scholar 

  43. Jung RE, Zembic A, Pjetursson BE, Zwahlen M, Thoma DS (2012) Systematic review of the survival rate and the incidence of biological, technical, and aesthetic complications of single crowns on implants reported in longitudinal studies with a mean follow-up of 5 years. Clin Oral Implants Res 23(Suppl 6):2–21

    PubMed  Google Scholar 

  44. Glauser R, Sailer I, Wohlwend A, Studer S, Schibli M, Scharer P (2004) Experimental zirconia abutments for implant-supported single-tooth restorations in esthetically demanding regions: 4-year results of a prospective clinical study. Int J Prosthodont 17:285–290

    PubMed  Google Scholar 

  45. Pjetursson BE, Sailer I, Zwahlen M, Hammerle CH (2007) A systematic review of the survival and complication rates of all-ceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part I: single crowns. Clin Oral Implants Res 18(Suppl 3):73–85

    PubMed  Google Scholar 

  46. Beier US, Kapferer I, Dumfahrt H (2012) Clinical long-term evaluation and failure characteristics of 1,335 all-ceramic restorations. Int J Prosthodont 25:70–78

    PubMed  Google Scholar 

  47. Heintze SD, Rousson V (2010) Fracture rates of IPS Empress all-ceramic crowns—a systematic review. Int J Prosthodont 23:129–133

    PubMed  Google Scholar 

  48. Wang X, Fan D, Swain MV, Zhao K (2012) A systematic review of all-ceramic crowns: clinical fracture rates in relation to restored tooth type. Int J Prosthodont 25:441–450

    PubMed  Google Scholar 

  49. Takeichi T, Katsoulis J, Blatz MB (2013) Clinical outcome of single porcelain-fused-to-zirconium dioxide crowns: a systematic review. J Prosthet Dent 110:455–461

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Florian Beuer.

Ethics declarations

Conflict of interest

The authors declare they have no competing interests.

Ethical approval

The requirements of the Helsinki Declaration were observed and the patients given informed consent. The ethical board of the Munich University (number 434/24) has reviewed and approved the study design.

Informed consent

Informed consent was obtained from all individual participants included in this study.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Cantner, F., Cacaci, C., Mücke, T. et al. Clinical performance of tooth- or implant-supported veneered zirconia single crowns: 42-month results. Clin Oral Invest 23, 4301–4309 (2019). https://doi.org/10.1007/s00784-019-02878-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00784-019-02878-0

Keywords

Navigation