Skip to main content

Advertisement

Log in

Evaluation of time and temperature storage in platelet counts in blood samples of dogs

  • Original Article
  • Published:
Comparative Clinical Pathology Aims and scope Submit manuscript

Abstract

The reliability of platelet counts obtained by different methods following different storage times/conditions is not well defined. The aim was to evaluate temporal changes in platelet count of canine blood samples submitted to two thermal storage conditions using three techniques of platelet counting. Blood samples were obtained from 40 dogs aged between 6 months and 12 years. Blood samples were collected by jugular venipuncture, separated into two aliquots, and stored in EDTA tubes: one kept at room temperature (RT group) and the other kept under refrigeration (RE group). The platelet count was performed using the hemocytometer method, blood smear counting, and automated counting immediately after blood collection (M0) and 30 min and 1, 2, 4, 6, and 24 h later in both groups. The platelet parameters provided by the electronic counter were also obtained. There was a significant difference in platelet counts between the manual and automated methods when the samples were processed 24 h after sample collection. The refrigerated samples remained with closer platelet values of the previous samples for longer than those stored at room temperature. The analysis of platelet parameters loses its validity when the samples are stored for more than 6 h. The plaquetogram is reliable when the sample is processed up to 4 h after collection, regardless of the storage method. The timing of the platelet count should not exceed 6 h after collection for refrigerated samples and 4 h for samples stored at room temperature, for all counting methods.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Abella NHG, Geffré A, Deshuillers PL et al (2014) Changes in hematology measurements in healthy and diseased dog blood stored at room temperature for 24 and 48 hours using the XT-2000iV analyzer. Vet Clin Pathol 43:24–35

    Article  Google Scholar 

  • Clark P, Mogg TD, Tvedten HW, Korcal D (2002) Artifactual changes in equine blood following storage, detected using the Advia 120 hematology analyzer. Vet Clin Pathol 31:90–94

    Article  Google Scholar 

  • Coelho E (1981) Técnicas de estudo da coagulação, 3rd edn. Santos, São Paulo, p 121

    Google Scholar 

  • Comar SR, Silva PH (2009) Determinação laboratorial e aplicação clínica dos parâmetros de volume plaquetário. RBAC 41(1):257–265

    Google Scholar 

  • Farias MG, Bó SD (2008) Determinação do intervalo de referência para o volume plaquetário médio (VPM) utilizando o analisador hematológico Pentra 120 ABX. RBAC 40(1):39–41

    Google Scholar 

  • Ferreira GS, Masson GCIH, Costa EDCP et al (2009) Plateletcrit, mean platelet volume and platelet distribution width: its expected values and correlation parameters in dogs from northern region of Brazil. In: World Small Animal Veterinary Association World Congress Proceedings. Universidade Federal Rural da Amazônia-UFRA, Belém

    Google Scholar 

  • Gao XM, Moore XL, Liu Y, Wang XY, Han LP, Su Y, Tsai A, Xu Q, Zhang M, Lambert GW, Kiriazis H, Gao W, Dart AM, du XJ (2016) Splenic release of platelets contributes to increased circulating platelet size and inflammation after myocardial infarction. Clin Sci 130:1089–1104

    Article  CAS  Google Scholar 

  • Gerday E, Baer VL, Lambert DK (2009) Testing platelet mass versus platelet count to guide platelet transfusions in the neonatal intensive care unit. Transfusion 49:2034–2039

    Article  Google Scholar 

  • Golwala ZM, Shah H, Gupta N, Sreenivas NGV, Puliyel JM (2016) Mean platelet volume (MPV), platelet distribution width (PDW), platelet count and plateletcrit (PCT) as predictors of in-hospital paediatric mortality: a case-control study. Afr Health Sci 16:356–362

    Article  Google Scholar 

  • Gulcu E, Durmaz Y, Karabay O (2013) Effect of severe sepsis on platelet count and their indices. Afr Health Sci 13(2):333–338

    Google Scholar 

  • Humann-Ziehank E, Ganter M (2012) Pre-analytical factors affecting the results of laboratory blood analyses in farm animal veterinary diagnostics. Animal 6:1115–1123

    Article  CAS  Google Scholar 

  • Jackson SR, Carter JM (1993) Platelet volume: laboratory measurement and clinical application. Blood Rev 7:104–113

    Article  CAS  Google Scholar 

  • Jain NC (1986) The platelets: structural, biochemical and functional aspects. In: Schalm’s veterinary hematology, 4th edn. Lea & Febiger, Philadelphia, pp 1–4

    Google Scholar 

  • Knoll JS, Rowell S (1996) Clinical hematology. In-clinic analysis, quality control, reference values and system selection. Veterinary Clinics of North America: Small Animal Practice, Philadelphia, pp 981–1002

    Google Scholar 

  • Lassen ED, Weisner G (2007) Tecnologia Laboratorial em Medicina Veterinária. In: Thrall MA (ed) Hematology and veterinary clinical biochemistry. São Paulo, Editora Roca, pp 3–36

    Google Scholar 

  • Matos JF, Carvalho MG, Dusse LMS et al (2008) O papel do RDW, da morfologia eritrocitária e de parâmetros plaquetários na diferenciação entre anemias microcíticas e hipocrômicas. Rev Bras Hematol Hemoter 30:463–469

    Google Scholar 

  • Médaille C, Briend-Marchal A, Braun JP (2002) Stability of selected hematology variables in canine blood kept at room temperature in EDTA for 24 and 48 hours. Vet Clin Pathol 35:18–23

    Article  Google Scholar 

  • Moreno A, Menke D (2002) Assessment of platelet numbers and morphology in the peripheral blood smear. Clin Lab Med 22:193–213

    Article  Google Scholar 

  • Norman EJ, Barron RC, Nash AS (2001) Prevalence of low automated platelet counts in cats: comparison with prevalence of thrombocytopenia based on blood smear estimation. Vet Clin Pathol 30:137–140

    Article  Google Scholar 

  • Olsen LH, Kristensen AT, Qvortrup K, Pedersen HD (2004) Comparison of manual and automated methods for determining platelet count in dogs with macrothombocitopenia. J Vet Diagn Investig 16:167–170

    Article  Google Scholar 

  • Pastor J, Cuenca R, Velarde R, Viñas L, Lavin S (1997) Evaluation of a hematology analyzer with canine and feline blood. Vet Clin Pathol 26:138–147

    Article  Google Scholar 

  • Prins MW, Van Leeuwen MW, Teske E (2009) Stability and reproducibility of advia 120-measured red blood cell and platelet parameters in dogs, cats, and horses, and the use of reticulocyte haemoglobin contente (CHr) in the diagnosis of iron deficiency. Tijdschr Diergeneeskd 134:272–278

    CAS  PubMed  Google Scholar 

  • Reardom DM, Hutchinson D, Preston FE, Trowbridge EA (1985) The routine measurement of platelet volume: a comparison of aperture impedance and flow cytometric systems. Clin Lab Haematol 7:251–257

    Article  Google Scholar 

  • Schäfers A, Meierhans S, Sauter-Louis C et al (2013) Reference values for haematological and clinical-chemical parameters in the dog. Tierarztl Prax Ausg K 41(3):163–172

  • Schwartz D, Sharkey L, Armstrong PJ, Knudson C, Kelley J (2014) Platelet volume and plateletcrit in dogs with presumed primary immune-mediated thrombocytopenia. J Vet Intern Med 28:1575–1579

    Article  CAS  Google Scholar 

  • Schweirgert A, Rezende FH, Fantoni DT, Moroz LR (2010) Avaliação da contagem plaquetária pelo contador automático QBC Vet Autoread® comparado com estimativa em esfregaço sanguíneo e contagem em hemocitômetro. Semin Cienc Agrar 31:1001–1008

    Article  Google Scholar 

  • Shi G, Morrell CN (2011) Platelets as initiators and mediators of inflammation at the vessel wall. Thromb Res 127:387–390

    Article  CAS  Google Scholar 

  • Smith JR, Smith KF, Brainard BM (2014) Platelet parameters from an automated hematology analyzer in dogs with inflammatory clinical diseases. Vet J 201:406–411

    Article  CAS  Google Scholar 

  • Souza AM, Pereira JJ, Campos SDE et al (2016) Platelet indices in dogs with thrombocytopenia and dogs with normal platelet counts. Arch Med Vet 48:27–281

    Article  Google Scholar 

  • Stokol T, Erb HN (2007) A comparison of platelet parameters in EDTA and citrate anticoagulated blood in dogs. Vet Clin Pathol 36:148–154

    Article  Google Scholar 

  • Tasker S, Cripps PJ, Mackin AJ (2001) Evaluation of methods of platelet counting in the cat. J Small Anim Pract 42:326–332

    Article  CAS  Google Scholar 

  • Thompson CB, Jakubowski JA (1988) The pathophysiology and clinical relevance of platelet heterogeneity. Blood 72:1–8

    Article  CAS  Google Scholar 

  • Topper MJ, Weller EG (2003) Hemostasis. In: Latimer KS, Mahaffey EA, Prasse KW (eds) Duncan & Prasse’s veterinary laboratory medicine: clinical pathology, 4th edn, pp 99–135

    Google Scholar 

  • Yilmaz Z, Eralp O, Ilcol YO (2008) Evaluation of platelet count and its association with plateletcrit, mean platelet volume, and platelet size distribution width in a canine model of endotoxemia. Vet Clin Pathol 37:159–163

    Article  Google Scholar 

  • Zelmanovic D, Hetherington EJ (1998) Automated analysis of feline platelets in whole blood, including platelet count, mean platelet volume and activation state. Vet Clin Pathol 27:2–9

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Antonise Mariely Jaguezeski.

Ethics declarations

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical approval

All applicable international, national, and/or institutional guidelines for and use of animals were followed.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Jaguezeski, A.M., Volpato, J., de Lorenzi Cancelier, C.D. et al. Evaluation of time and temperature storage in platelet counts in blood samples of dogs. Comp Clin Pathol 29, 155–160 (2020). https://doi.org/10.1007/s00580-019-03046-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00580-019-03046-2

Keywords

Navigation