Abstract
Laser guidance facilitates needle alignment in-plane to the ultrasound beam. Once the ultrasound image is optimized, there is no further need to maneuver the probe. Therefore, we designed a laser mount probe holder prototype, and examined the ease of visualization of the needle tip using the laser mount probe holder. The needle brightness was quantitatively measured using an image analysis software. We found that the laser mount probe holder is useful, not only to visualize the needle tip in the ultrasound plane, but also to fix the best ultrasound image.
References
Sites BD, Antonakakis JG. Ultrasound guidance in regional anesthesia: state of the art review through challenging clinical scenarios. Local Reg Anesth. 2009;2:1–14.
Turan A, Babazade R, Elsharkawy H, Esa WA, Maheshwari K, Farag E, Zimmerman NM, Soliman LM, Sessler DI. Novel needle guide reduces time to perform ultrasound-guided femoral nerve catheter placement: a randomised controlled trial. Eur J Anaesthesiol. 2017;34:135–40.
Wang AZ, Zhang WX, Jiang W. A needle guide can facilitate visualization of needle passage in ultrasound-guided nerve blocks. J Clin Anesth. 2009;21:230–2.
Gupta RK, Lane J, Allen B, Shi Y, Schildcrout JS. Improving needle visualization by novice residents during an in-plane ultrasound nerve block simulation using an in-plane multiangle needle guide. Pain Med. 2013;14:1600–7.
Ueshima H, Kitamura A. The use of a needle guide kit improves the stability of ultrasound-guided techniques. J Anesth. 2015;29:803–4.
Collins GB, Fanou EM, Young J, Bhogal P. A comparison of free-hand vs laser-guided long-axis ultrasound techniques in novice users. Br J Radiol. 2013;86(1029):20130026.
Tsui BC. Facilitating needle alignment in-plane to an ultrasound beam using a portable laser unit. Reg Anesth Pain Med. 2007;32:84–8.
Osaka Y, Morita Y. A combination of probe holder and laser navigation. JA Clin Rep. 2018;4:19.
Author information
Authors and Affiliations
Contributions
YO: This author designed and performed this study and wrote the manuscript; YM: This author helped in the preparation of the final manuscript, in responding to the critical comments, and in obtaining the final approval.
Corresponding author
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
About this article
Cite this article
Osaka, Y., Morita, Y. A laser mount probe holder facilitates fixation of the optimized ultrasound image and needle alignment in-plane to the ultrasound beam during ultrasound-guided peripheral nerve block. J Anesth 33, 620–622 (2019). https://doi.org/10.1007/s00540-019-02666-w
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00540-019-02666-w