Laser guidance facilitates needle alignment in-plane to the ultrasound beam. Once the ultrasound image is optimized, there is no further need to maneuver the probe. Therefore, we designed a laser mount probe holder prototype, and examined the ease of visualization of the needle tip using the laser mount probe holder. The needle brightness was quantitatively measured using an image analysis software. We found that the laser mount probe holder is useful, not only to visualize the needle tip in the ultrasound plane, but also to fix the best ultrasound image.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1

References

  1. Sites BD, Antonakakis JG. Ultrasound guidance in regional anesthesia: state of the art review through challenging clinical scenarios. Local Reg Anesth. 2009;2:1–14.

    Article  PubMed  PubMed Central  Google Scholar 

  2. Turan A, Babazade R, Elsharkawy H, Esa WA, Maheshwari K, Farag E, Zimmerman NM, Soliman LM, Sessler DI. Novel needle guide reduces time to perform ultrasound-guided femoral nerve catheter placement: a randomised controlled trial. Eur J Anaesthesiol. 2017;34:135–40.

    PubMed  Google Scholar 

  3. Wang AZ, Zhang WX, Jiang W. A needle guide can facilitate visualization of needle passage in ultrasound-guided nerve blocks. J Clin Anesth. 2009;21:230–2.

    Article  PubMed  Google Scholar 

  4. Gupta RK, Lane J, Allen B, Shi Y, Schildcrout JS. Improving needle visualization by novice residents during an in-plane ultrasound nerve block simulation using an in-plane multiangle needle guide. Pain Med. 2013;14:1600–7.

    Article  PubMed  Google Scholar 

  5. Ueshima H, Kitamura A. The use of a needle guide kit improves the stability of ultrasound-guided techniques. J Anesth. 2015;29:803–4.

    Article  PubMed  Google Scholar 

  6. Collins GB, Fanou EM, Young J, Bhogal P. A comparison of free-hand vs laser-guided long-axis ultrasound techniques in novice users. Br J Radiol. 2013;86(1029):20130026.

    Article  CAS  PubMed  PubMed Central  Google Scholar 

  7. Tsui BC. Facilitating needle alignment in-plane to an ultrasound beam using a portable laser unit. Reg Anesth Pain Med. 2007;32:84–8.

    Article  PubMed  Google Scholar 

  8. Osaka Y, Morita Y. A combination of probe holder and laser navigation. JA Clin Rep. 2018;4:19.

    Article  PubMed  PubMed Central  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Contributions

YO: This author designed and performed this study and wrote the manuscript; YM: This author helped in the preparation of the final manuscript, in responding to the critical comments, and in obtaining the final approval.

Corresponding author

Correspondence to Yoshimune Osaka.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Osaka, Y., Morita, Y. A laser mount probe holder facilitates fixation of the optimized ultrasound image and needle alignment in-plane to the ultrasound beam during ultrasound-guided peripheral nerve block. J Anesth 33, 620–622 (2019). https://doi.org/10.1007/s00540-019-02666-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00540-019-02666-w

Keywords

Navigation