Abstract
Background
The flap repair method is the most frequently used technique for covering congenital or acquired defects that disrupt the integrity of body. We aimed to investigate maximum size of reliable lateral thoracic artery-based faciocutaneous (LTAF) flap and to determine its usage in which part of the body defects in rabbits.
Methods
In this study, 10 white New Zealand rabbits were used. The study had two parts. In part 1, a total of 5 rabbits were used, two of them in barium microangiography and three of them to investigate flap viability. Flap survival was investigated clinically and fluorescent dye. In the second part, potential target points for the flap were determined on 5 rabbits.
Results
In the first part, average 8.1 cm wide and average 6.8 cm length of LTAF flaps were harvested and flaps resutured. Neither partial nor total flap necrosis was observed in all animals. In the second part, average 7.7 cm wide and average 6.5 cm length of LTAF flaps were harvested and transferred target tissue. The flaps that covered on created defects on the ear, face, neck, feet, and contralateral back of the rabbits were followed for 6 weeks. The partial loss of tissue in the neck and back were 25% and10%, respectively.
Conclusions
LTAF flap is an ideal experimental model that can be used in large defects, have a long pedicle, wide arc of rotation, and being as thin as possible to configurate.
Level of evidence: Not gradable.
Similar content being viewed by others
Data Availability
Data is available from the corresponding author.
References
Minh TC, Lu’o’ng HV, Ngoc PT, An HM (2009) Canine lateral thoracic fasciocutaneous flap: an experimental study. Int J Surg 7:472–475. https://doi.org/10.1016/j.ijsu.2009.07.009
Bali U, Gungor M, Yoleri L (2016) Lateral thoracic artery perforator-based flap: a new experimental model. J Surg Res 200:738–742. https://doi.org/10.1016/j.jss.2015.08.028
Delaere PR, HardilloJ HR et al (2001) Prefabrication of composite tissue for improved tracheal reconstruction. Ann Otol Rhinol Laryngol 110:849–860
Okumuş A, Çizmeci O, Kabakas F et al (2005) Circumferential tracheal reconstruction with a prefabricated axial bio-synthetic flap: experimental study. Int J of Ped Otorhinolaryngol 69:335–344
Delaere PR, Hardillo J (2003) Tubes of vascularized cartilage used for replacement of rabbit cervical trachea. Ann Otol Rhinol Laryngol 112:807–812
Kuvat SV, Taşkın Ü, Yücebaş K, Tansuker HD, Oktay MF, Kozanoğlu E, Aydın S (2017) Extended lateral thoracic fasciocutaneous biosynthetic flap for reconstruction of full-thickness partial external ear defects: an experimental study. Eur Arch Otorhinolaryngol 274:489–493. https://doi.org/10.1007/s00405-016-4238-4
Lange K, Boyd LJ (1942) The use of fluorescein to determinate the adequacy of the circulation. Med Clin N Am 26:943
Bayramiçili M (2005) Deneysel mikrocerrahi: Temel Araştırma, Doku ve Organ Modelleri. İstanbul, Nobel yayınevi
Aydın EO, Algan S, Tan O et al (2019) A novel method for flap delay vacuum assisted flap delay: an experimental study in rabbits. J Plast Surg Hand Surg 53:208–215. https://doi.org/10.1080/2000656X.2019.1582425
Yu L, Zhou JL, Zhao ZJ (2015) An experimental study of auricular reconstruction using a thin porous silastic frame assisted by tissue expansion: an animal study. Aesth Plast Surg 39:602–607. https://doi.org/10.1007/s00266-015-0510-z
Luo X, Liu J, Chen H et al (2020) The feasibility and survival mechanism of a large free flap supported by a novel hybrid perfusion mode. Oral Oncol 101:104506. https://doi.org/10.1016/j.oraloncology.2019.104506
Finseth F, Cutting C (1978) An experimental neurovascular island skin flap for the study of the delay phenomenon. Plast Reconstr Surg 61:412–420
Aihara H, Tanino R, Osada M et al (1996) Attempt to obtain greater dermal depth of vascular injury using dye-enhanced laser technique: a new approach. Lasers Surg Med 18:260–264
de Chalain T, Phillips JH (1997) Design and development of a fascioperiosteal flap for use in experimental cranial surgery in a porcine model. J Craniofac Surg 8:501–505
Williams JD, Romo T 3rd, Sclafani AP et al (1997) Porous high-density polyethylene implants in auricular reconstruction. Arch Otolaryngol Head Neck Surg 123:578–583
Garfein ES, Orgill DP, Pripaz JJ (2003) Clinical applications of tissue engineered constructs. Clin Plast Surg 30:485–498
Acknowledgements
We thank Dr Özgür Pilancı and Dr Ümit Seza Tetikkurt Abanalı for their contributions.
Funding
The authors declare that no funds, grants, or other support were received during the preparation of this manuscript.
Author information
Authors and Affiliations
Contributions
All authors contributed to the study conception and design. Material preparation, data collection, and analysis were performed by corresponding author and co-author. The first draft of the manuscript was written by corresponding author and all authors commented on previous versions of the manuscript. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics approval
This study was performed in strict accordance with the recommendations in the Guide for the Care and Use of Laboratory Animals. The experiment was performed at the laboratory in the Experimental Surgery Research and Skill Development Training Center of Bağcılar Training and Research Hospital. Ethics committee approval was obtained from the local ethics committee for animal experiments (HADYEK) (no: 2013/32). This study has been approved by the appropriate animal care and uses committee.
Conflict of interest
Mehmet Sağır and Samet Vasfi Kuvat declare no conflict of interest.
Additional information
Publisher's note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.
About this article
Cite this article
Sağır, M., Kuvat, S.V. The versatile use of extended lateral thoracic artery-pedicled fasciocutaneous flap: an experimental study. Eur J Plast Surg 46, 947–952 (2023). https://doi.org/10.1007/s00238-023-02106-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00238-023-02106-9