The versatile use of extended lateral thoracic artery-pedicled fasciocutaneous flap: an experimental study

  • Experimental Study
  • Published:
European Journal of Plastic Surgery Aims and scope Submit manuscript

Abstract

Background

The flap repair method is the most frequently used technique for covering congenital or acquired defects that disrupt the integrity of body. We aimed to investigate maximum size of reliable lateral thoracic artery-based faciocutaneous (LTAF) flap and to determine its usage in which part of the body defects in rabbits.

Methods

In this study, 10 white New Zealand rabbits were used. The study had two parts. In part 1, a total of 5 rabbits were used, two of them in barium microangiography and three of them to investigate flap viability. Flap survival was investigated clinically and fluorescent dye. In the second part, potential target points for the flap were determined on 5 rabbits.

Results

In the first part, average 8.1 cm wide and average 6.8 cm length of LTAF flaps were harvested and flaps resutured. Neither partial nor total flap necrosis was observed in all animals. In the second part, average 7.7 cm wide and average 6.5 cm length of LTAF flaps were harvested and transferred target tissue. The flaps that covered on created defects on the ear, face, neck, feet, and contralateral back of the rabbits were followed for 6 weeks. The partial loss of tissue in the neck and back were 25% and10%, respectively.

Conclusions

LTAF flap is an ideal experimental model that can be used in large defects, have a long pedicle, wide arc of rotation, and being as thin as possible to configurate.

Level of evidence: Not gradable. 

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

Data Availability

Data is available from the corresponding author.

References

  1. Minh TC, Lu’o’ng HV, Ngoc PT, An HM (2009) Canine lateral thoracic fasciocutaneous flap: an experimental study. Int J Surg 7:472–475. https://doi.org/10.1016/j.ijsu.2009.07.009

    Article  Google Scholar 

  2. Bali U, Gungor M, Yoleri L (2016) Lateral thoracic artery perforator-based flap: a new experimental model. J Surg Res 200:738–742. https://doi.org/10.1016/j.jss.2015.08.028

    Article  PubMed  Google Scholar 

  3. Delaere PR, HardilloJ HR et al (2001) Prefabrication of composite tissue for improved tracheal reconstruction. Ann Otol Rhinol Laryngol 110:849–860

    Article  CAS  PubMed  Google Scholar 

  4. Okumuş A, Çizmeci O, Kabakas F et al (2005) Circumferential tracheal reconstruction with a prefabricated axial bio-synthetic flap: experimental study. Int J of Ped Otorhinolaryngol 69:335–344

    Article  Google Scholar 

  5. Delaere PR, Hardillo J (2003) Tubes of vascularized cartilage used for replacement of rabbit cervical trachea. Ann Otol Rhinol Laryngol 112:807–812

    Article  PubMed  Google Scholar 

  6. Kuvat SV, Taşkın Ü, Yücebaş K, Tansuker HD, Oktay MF, Kozanoğlu E, Aydın S (2017) Extended lateral thoracic fasciocutaneous biosynthetic flap for reconstruction of full-thickness partial external ear defects: an experimental study. Eur Arch Otorhinolaryngol 274:489–493. https://doi.org/10.1007/s00405-016-4238-4

    Article  PubMed  Google Scholar 

  7. Lange K, Boyd LJ (1942) The use of fluorescein to determinate the adequacy of the circulation. Med Clin N Am 26:943

    Article  Google Scholar 

  8. Bayramiçili M (2005) Deneysel mikrocerrahi: Temel Araştırma, Doku ve Organ Modelleri. İstanbul, Nobel yayınevi

  9. Aydın EO, Algan S, Tan O et al (2019) A novel method for flap delay vacuum assisted flap delay: an experimental study in rabbits. J Plast Surg Hand Surg 53:208–215. https://doi.org/10.1080/2000656X.2019.1582425

    Article  PubMed  Google Scholar 

  10. Yu L, Zhou JL, Zhao ZJ (2015) An experimental study of auricular reconstruction using a thin porous silastic frame assisted by tissue expansion: an animal study. Aesth Plast Surg 39:602–607. https://doi.org/10.1007/s00266-015-0510-z

    Article  Google Scholar 

  11. Luo X, Liu J, Chen H et al (2020) The feasibility and survival mechanism of a large free flap supported by a novel hybrid perfusion mode. Oral Oncol 101:104506. https://doi.org/10.1016/j.oraloncology.2019.104506

    Article  CAS  PubMed  Google Scholar 

  12. Finseth F, Cutting C (1978) An experimental neurovascular island skin flap for the study of the delay phenomenon. Plast Reconstr Surg 61:412–420

    Article  CAS  PubMed  Google Scholar 

  13. Aihara H, Tanino R, Osada M et al (1996) Attempt to obtain greater dermal depth of vascular injury using dye-enhanced laser technique: a new approach. Lasers Surg Med 18:260–264

    Article  CAS  PubMed  Google Scholar 

  14. de Chalain T, Phillips JH (1997) Design and development of a fascioperiosteal flap for use in experimental cranial surgery in a porcine model. J Craniofac Surg 8:501–505

    Article  PubMed  Google Scholar 

  15. Williams JD, Romo T 3rd, Sclafani AP et al (1997) Porous high-density polyethylene implants in auricular reconstruction. Arch Otolaryngol Head Neck Surg 123:578–583

    Article  CAS  PubMed  Google Scholar 

  16. Garfein ES, Orgill DP, Pripaz JJ (2003) Clinical applications of tissue engineered constructs. Clin Plast Surg 30:485–498

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

We thank Dr Özgür Pilancı and Dr Ümit Seza Tetikkurt Abanalı for their contributions.

Funding

The authors declare that no funds, grants, or other support were received during the preparation of this manuscript.

Author information

Authors and Affiliations

Authors

Contributions

All authors contributed to the study conception and design. Material preparation, data collection, and analysis were performed by corresponding author and co-author. The first draft of the manuscript was written by corresponding author and all authors commented on previous versions of the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Mehmet Sağır.

Ethics declarations

Ethics approval

This study was performed in strict accordance with the recommendations in the Guide for the Care and Use of Laboratory Animals. The experiment was performed at the laboratory in the Experimental Surgery Research and Skill Development Training Center of Bağcılar Training and Research Hospital. Ethics committee approval was obtained from the local ethics committee for animal experiments (HADYEK) (no: 2013/32). This study has been approved by the appropriate animal care and uses committee.

Conflict of interest

Mehmet Sağır and Samet Vasfi Kuvat declare no conflict of interest.

Additional information

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sağır, M., Kuvat, S.V. The versatile use of extended lateral thoracic artery-pedicled fasciocutaneous flap: an experimental study. Eur J Plast Surg 46, 947–952 (2023). https://doi.org/10.1007/s00238-023-02106-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00238-023-02106-9