Skip to main content
Log in

Laser-doppler flowmetry

A review of its application for measuring cerebral and spinal cord blood flow

  • Original Articles
  • Published:
Molecular and Chemical Neuropathology

Abstract

Laser-Doppler flowmetry is a new technique for noninvasive and continuous measurement of local microcirculatory cerebral and spinal-cord blood flow. The flow estimate by this technique is based on the assessment of the Doppler shift of low-power laser light, which is scattered by moving red blood cells. Laser-Doppler flowmetry has been validated for various organs, including the central nervous system. These studies revealed a linear relationship between relative changes of the Doppler signal and blood flow over a wide range of pharmacological as well as pathological flow alterations, including cerebral ischemia. The usefulness of laser-Doppler flowmetry in experimental as well as clinical applications has received growing attention. The superiority of the technique lies in its high spatial and temporal resolution. Disadvantages are the difficulty of obtaining absolute flow values and the sensitivity to artifacts. The versatility and on-line capacity of laser-Doppler flowmetry might allow new insights into the pathophysiology of alterations of the cerebral and spinal-cord microcirculation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Ahn H., Lindhagen J., Nilsson G. E., Salerud E. G., Jodal M., and Lundgren O. (1985) Evaluation of laser Doppler flowmetry in the assessment of intestinal blood flow in cat.Gastroenterology 88, 951–957.

    PubMed  CAS  Google Scholar 

  • Arbit E., DiResta G. R., Bedford R. F., Shah N. K., and Galicich J. H. (1989) Intraoperative measurement of cerebral and tumor blood flow with laser-Dopper flowmetry.Neurosurgery 24, 166–170.

    Article  PubMed  CAS  Google Scholar 

  • Bonner R. and Nossal R. (1988) Model for laser Doppler measurements of blood flow in tissue. Appl. Optics20, 2097–2107.

    Article  Google Scholar 

  • Bonner R. F., Clem T. R., Bowen P. D., and Bowman R. L. (1988) Laser-Doppler continuous real-time monitor of pulsatile and mean blood flow in tissue microcirculation,Scattering Techniques Applied to Supramolecular and Non Equilibrium Systems (Chen S. H., Chu B., and Nossal R., eds.) pp. 685–702, Plenum, New York.

    Google Scholar 

  • Chen R. Y. Z., Fan F.-C., Schuessler G. B., Usami S., and Chien S. (1983) Effects of sphere size and injection site on regional cerebral blood flow measurements.Stroke 14, 769–776.

    PubMed  CAS  Google Scholar 

  • Chen S. T., Hsu C. Y., Hogan E. L., Mariq H., and Balentine J. D. (1986) A model of focal ischemic stroke in the rat: Reproducible extensive cortical infarction.Stroke 17, 738–743.

    PubMed  CAS  Google Scholar 

  • DiResta G. R., Kiel J. W., Riedel G. L., Kaplan P., and Sheperd A. P. (1987) Hybrid blood flow probe for simultaneous H2 clearance and laser-Doppler velocimetry.Am. J. Physiol. 253, G573-G581.

    PubMed  CAS  Google Scholar 

  • Dirnagl U., Kaplan B., Jacewicz M., and Pulsinelli W. (1989) Continuous measurement of cerebral cortical blood flow by laser-doppler flowmetry in a rat stroke model.J. Cereb. Blood Flow Metab. 9, 589–596.

    PubMed  CAS  Google Scholar 

  • Eyre J. A., Essex T. J. H., Flecknell P. A., Bartholomew P. H., and Sinclair J. I. (1988) A comparison of measurements of cerebral blood flow in the rabbit using laser Doppler spectroscopy and radionuclide labelled microspheres.Clin. Phys. Physiol. Meas. 9, 65–74.

    Article  PubMed  CAS  Google Scholar 

  • Fasano V. A., Urciuoli R., Bolognese P., and Mostert M. (1988) Intraoperative use of laser-Doppler in the study of cerebral microvascular circulation.Acta Neurochir. 95, 40–48.

    Article  CAS  Google Scholar 

  • Frerichs K. U., Lindsberg P. J., Hallenbeck J. M., and Feuerstein G. Z. Platelet-activating factor and progressive brain damage following focal brain injury.J. Neurosurg. (in press).

  • Haberl R. L., Heizer M. L., Marmarou A., and Ellis E. F. (1989a) Laser-Doppler assessment of brain microcirculation: Effect of systemic alterations.Am. J. Physiol. 256, H1247-H1254.

    PubMed  CAS  Google Scholar 

  • Haberl R. L., Heizer M. L., and Ellis E. F. (1989b) Laser-Doppler assessment of brain microcirculation: Effect of local alterations.Am. J. Physiol. 256, H1255-H1260.

    PubMed  CAS  Google Scholar 

  • Halsey J. H., Capra N. F., and McFarland R. S. (1977) Use of hydrogen for measurement of regional cerebral blood flow. Problem of intercompartmental diffusion.Stroke 8, 351–357.

    PubMed  CAS  Google Scholar 

  • Holloway G. A. and Watkins D. W. (1977) Laser-Doppler measurement of cutaneous blood flow.J. Invest. Dermatol. 69, 306–309.

    Article  PubMed  Google Scholar 

  • Lacombe P., Meric P., and Seylaz J. (1980) Validity of cerebral blood flow measurements obtained with quantitative tracer technique.Brain Res. Rev. 2, 105–169.

    Article  Google Scholar 

  • Lindsberg P. J., O’Neill J. T., Paakkari I. A., Hallenbeck J. M., and Feuerstein G. (1989) Validation of laser-Doppler flowmetry in measurement of spinal cord blood flow.Am. J. Physiol. 257, H674-H680.

    PubMed  CAS  Google Scholar 

  • Nilsson G. E., Tenland T., and Oberg P. A. (1980) Evaluation of a laser Doppler flowmeter for measurement of tissue blood flow.IEEE Trans. Biomed. Eng. BME-27, 597–604.

    Article  PubMed  CAS  Google Scholar 

  • Riva C., Ross B., and Benedek G. B. (1972) Laser Doppler measurements of blood flow in capillary tubes and retinal arteries.Invest. Opthalmol. 11, 936–944.

    CAS  Google Scholar 

  • Rosenblum B. R., Bonner R. F., and Oldfield E. H. (1987) Intraoperative measurement of cortical blood flow adjacent to cerebral AVM using laser Doppler velocimetry.J. Neurosurg. 66, 369–399.

    Google Scholar 

  • Sakurada O., Kennedy C., Jehle J., Brown J. D., Carbin G. L. and Sokoloff L. (1978) Measurement of local cerebral blood flow with iodo[14C]antipyrine.Am. J. Physiol. 234, H59-H66.

    PubMed  CAS  Google Scholar 

  • Sheperd A. P. and Riedel G. L. (1982) Continuous measurement of intestinal mucosal blood flow by laser-Doppler velocimetry.Am. J. Physiol. 242, G668-G672.

    Google Scholar 

  • Skarphedinsson J. O., Hårding H., and Thoreń P. (1988) Repeated measurements of cerebral blood flow in rats. Comparisons between the hydrogen clearance method and laser Doppler flowmetry.Acta Physiol. Scand. 134, 133–142.

    Article  PubMed  CAS  Google Scholar 

  • Skarphedinsson J. O., Sandberg M., Hagberg H., Carlsson S., and Thoreń P. (1989a) Relative cerebral ischemia in SHR due to hypotensive hemorrhage: Cerebral function, blood flow and extracellular levels of lactate and purine catabolites.J. Cereb. Blood Flow Metab. 9, 364–372.

    PubMed  CAS  Google Scholar 

  • Skarphedinsson J. O., Delle M., Hoffmann P., and Thoreń P. (1989b) The effects of naloxone on cerebral blood flow and cerebral function during relative cerebral ischemia.J. Cereb. Blood Flow Metab. 9, 515–522.

    PubMed  CAS  Google Scholar 

  • Stern M. D., Lappe D. L., Bowen P. D., Chimosky J. E., Holloway G. A., Keiser H. R., and Bowman R. L. (1977) Continuous measurement of tissue blood flow by laser-Doppler spectroscopy.Am. J. Physiol. 232, H441-H448.

    PubMed  CAS  Google Scholar 

  • Tamura A., Graham D. I., McGulloch J., and Teasdale G. M. (1981) Focal cerebral ischaemia in the rat: 2. Regional cerebral blood flow determined by [14C]iodoantipyrine autoradiography following middle cerebral artery occlusion.J. Cereb. Blood Flow Metab. 1, 61–69.

    PubMed  CAS  Google Scholar 

  • Tomida S., Wagner H. G., Klatzo I., and Nowak T. S. (1989) Effect of acute electrode placement on regional CBF in the gerbil: A comparison of blood flow measured by hydrogen clearance, [3H]nicotine, and [14C]iodoantipyrine techniques.J. Cereb. Blood Flow Metab. 9, 79–86.

    PubMed  CAS  Google Scholar 

  • Young W. (1980) H2 clearance measurement of blood flow: A review of techniques and polarographic principles.Stroke 11, 552–564.

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Frerichs, K.U., Feuerstein, G.Z. Laser-doppler flowmetry. Molecular and Chemical Neuropathology 12, 55–70 (1990). https://doi.org/10.1007/BF03160057

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03160057

Index Entries

Navigation