Skip to main content

Reliability and Accuracy of Echocardiography for Follow-up Studies after Intervention

  • Chapter
Digital Techniques in Echocardiography

Abstract

By two-dimensional echocardiography limitations of M-mode echocardiography have been eliminated. As a direct and noninvasive method two-dimensional echocardiography seems to be an ideal method for analysis of left ventricular function in follow-up studies. In relation to other methods there are no limitations concerning x-ray exposure, physicians and patients safety. Before different studies can be discussed, reliability and accuracy of two-dimensional echocardiography have to be evaluated. Beat-to-beat, day-to-day, intra- and interobserver variability will be discussed, followed by description of follow-up studies after intervention.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 169.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 219.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 219.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. Erbel R, Krebs W, Henn G, Schweizer P, Richter HA, Meyer J, Effert S: Comparison of single-plane and biplane volume determination by two-dimensional echocardiography. I. Asymmetric model hearts. Eu Heart J 1982; 3: 469–480.

    CAS  Google Scholar 

  2. Erbel R, Schweizer P, Meyer J, Krebs W, Yalkinoglu Ö, Effert S: Sensitivity of cross-sectional echocardiography in detection of impaired global and regional left ventricular function: prospective study. Int J Cardiol 1985; 7: 375–389.

    Article  PubMed  CAS  Google Scholar 

  3. Erbel R: Funktionsdiagnostik des linken Ventrikels mittels zweidimensionaler Echokardiographie. Steinkopff Verlag Darmstadt, 1983.

    Book  Google Scholar 

  4. Cohn P, Levine JA, Bergeron A, Gorlin R: Reproducibility of the angiography left ventricular ejection fraction in patients with coronary artery disease. Am Heart J 1984; 88: 713–720.

    Article  Google Scholar 

  5. Carleton RA: Change in left ventricular volume during angiocardiography. Am J Cardiol 1971; 27: 60–463.

    Article  Google Scholar 

  6. Erbel R, Neuhaus KL, Spiller P, Benn M, Kreuzer H: Beeinflussung der systolischen und diastolischen Ventrikelfunktion durch Kontrastmittelinjection in den linken Ventrikel. Z Kardiol 1976; 65: 305–318.

    PubMed  CAS  Google Scholar 

  7. Vine DL, Hegg TD, Dodge HT, Stewart DK, Frimer M: Immediate effect of contrast medium injection on left ventricular volumes and ejection fraction - a study using metallic epicardial markers. Circulation 1977; 56: 379–384.

    PubMed  CAS  Google Scholar 

  8. Mnulty JH, Kremkau EL, Rosch J, Hattenhauer MT, Rahimtoola SH: Spontaneous changes in left ventricular function between sequential studies. Am J Cardiol 1974; 34: 23–28.

    Article  Google Scholar 

  9. Lapido GOA, Dunn FG, Pringle TH, Bastian B, Lawrie TDV: Serial measurements of left ventricular dimensions by echocardiography. Assessment of weak-to-weak, inter- and intra- observer variability in normal subjects and patients with valvular heart disease. Br Heart J 1980; 44: 284–289.

    Article  Google Scholar 

  10. Pietro DA, Voelkel AG, Ray BJ, Parisi AF: Reproducibility of echocardiography. A study evaluating the variability of serial echocardiographic measurements. Chest 1981; 79: 29–32.

    Article  PubMed  CAS  Google Scholar 

  11. Stefadouros MA, Canedo MJ: Reproducibility of echocardiographic estimates of left ventricular dimensions. Br Heart J 1977; 39: 390–398.

    Article  PubMed  CAS  Google Scholar 

  12. Erbel R, Schweizer P, Merx W, Effert S: Kontrollierte Langzeitbehandlung des Mitralklappenprolapssyndroms mit Propranolol. Z Kardiol 1978; 67: 729–735.

    PubMed  CAS  Google Scholar 

  13. Martin MA, Fiedler NRJ: Echocardiography in cardiovascular drug assessment. Br Heart J 1979; 41: 536–543.

    Article  PubMed  CAS  Google Scholar 

  14. Wackers FJT, Berger HJ, Johnstone DE, Goldman L, Reduto A, Langou RA, Gottschalk B, Zaret L: Multiple gated cardiac blood pool imaging for left ventricular ejection fraction, validation of the technique and assessment of variability. Am J Cardiol 1979; 43: 1159–1166.

    Article  PubMed  CAS  Google Scholar 

  15. Sigel H, Nechwatal W, Stauch M: Zur Frage der Reproduzierbarkeit von Parameern der quantitativen globalen und regionalen Lavangiographie im intra- und interindividuellen Observer-Vergleich. Z Kardiol 1981; 70: 742–747.

    PubMed  CAS  Google Scholar 

  16. Chaitman BR, Demots H, Bristow JD, Rösch J, Rahimtoola SH: Objective and subjective analysis of left ventricular angiograms. Circulation 1975; 52: 420–425.

    PubMed  CAS  Google Scholar 

  17. Okada RD, Kirshenbaum HD. Kushner FG, Strauss W, Dinsmore RE, Newell JB, Boucher CA, Block PC, Pohost GM: Observer variance in the qualitative evaluation of left ventricular wall motion and quantitation of left ventricular ejection fraction using rest and exercise multigated blood pool imaging. Circulation 1980; 61: 128–136.

    PubMed  CAS  Google Scholar 

  18. Touche T, Prasquier R, Merillon JP, Barthelemy M, Hanoun HC, Vervin P, Gourgon R: Mesure des volumes ventriculaires gauches par echographic bidimensinelle a partir d’une coupe apicale. Arch Med Coeur 1980; 73: 691–700.

    CAS  Google Scholar 

  19. Sold G, Kreuzer H: Erlaubt die zweidimensionale Echokardiographie eine verläßliche Bestimmung linksventrikulärer Funktionsgrößen? Kontroverse Ansichten in der Echokardiographie.Hrsg G Biamino, L Lange, Schattauer, Stuttgart, 1984, p 265–275.

    Google Scholar 

  20. Rogers WJ, Bream PR, Smith LR, Williams SE, Rackley CE, Russell Jr RO: Effect if filming projection and interobserver variability on angiographic biplane left ventricular volume determination. Circulation 1979; 59: 96–104.

    PubMed  CAS  Google Scholar 

  21. Greene DG, Carlisle R, Grant C, Brunnell L: Estimation of left ventricular volume by one-plane cineangiography. Circulation 1967; 35: 61–69.

    PubMed  CAS  Google Scholar 

  22. Erbel R, Schweizer P, Lambertz H, Henn G, Meyer J, Krebs W, Effert S: Echoventriculography-A simultaneous analysis of two-dimensional echocardiography and cineventriculography. Circulation 1984; 67: 205–215.

    Article  Google Scholar 

  23. Mehmel HC, Katus H, Bassemir KR, von Olshausen K, Zebe H, Kubler W: Comparison between the effect of postextrasystolic potentiation and the effect of nitrates on the left ventricular function for the differentiation between reversible and irreversible left ventricular asynergy. Basic Res Cardiol 1980; 75: 390–399.

    Article  PubMed  CAS  Google Scholar 

  24. Azancot J, Beaufils P, Masquet C, Georgiopoulos G, Dabalis D, Lorente P, Baudouy Y, Slama R, Bouvrain Y: Detection of residual myocardial function in acute transmural infarction using postextrasystolic potentiation. Circulation 1981; 64: 46–53.

    Article  PubMed  CAS  Google Scholar 

  25. Erbel R, Schweizer P, Lambertz H, Voelker W, Meyer J, Effert S: Echoventricular analysis of prenalterol induced changes of left ventricular function. Circulation 1981; 64 Suppl A: 49.

    Google Scholar 

  26. Erbel R, Meyer J, Lambertz H, Schweizer P, Voelker W, Krebs W, Braun G, Effert S: Hemodynamic effects of prenalterol in patients with ischemic heart disease and congestive cardiomyopathy. Circulation 1982; 66: 361–369.

    Article  PubMed  CAS  Google Scholar 

  27. Erbel R, Pop T, Meinertz Th, Kasper W, Schreiner G, Henkel B, Henrich KJ, Pfeiffer C, Rupprecht HJ, Meyer J: Combined medical and mechanical recanalization in acute myocardial infarction. Cath Cardiovasc Diagn 1985; 11: 361–377.

    Article  CAS  Google Scholar 

  28. Erbel R, Pop T, Meinertz T, Clas W, Henkel B, Schreiner G, Steuernagel C, Meyer J: Analysis of left ventricular function before and immediately after recnalaization in acute myocardial infarction. Europ Heart J 1984; 5 Suppl 1: 220.

    Google Scholar 

  29. Erbel R, Schreiner G, Henkel B, Pop T, Meyer J: Improved ischemic tolerance during percutaneous transluminal coronary angioplasty by intracoronary injection of nitroglycerine. Z Kardiol 1983; 72 Suppl 3: 71–73.

    PubMed  Google Scholar 

  30. Schreiner G, Erbel R, Henkel B, Pop T, Meyer J: Improved ischemic tolerance during percutaneous coronary angioplasty (PTCA) by antianginal drugs. Europ Heart J 1984; 5 Suppl I: 93.

    Google Scholar 

  31. Grube E: Automatic contour detection and subtraction technique for analysis of left ventricular function. In: Digital Techniques in Echocardiography, ed J Roelandt, Martinus Nijhoff, Dordrecht (in press).

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1987 Martinus Nijhoff Publishers, Dordrecht

About this chapter

Cite this chapter

Erbel, R. et al. (1987). Reliability and Accuracy of Echocardiography for Follow-up Studies after Intervention. In: Roelandt, J. (eds) Digital Techniques in Echocardiography. Developments in Cardiovascular Medicine, vol 64. Springer, Dordrecht. https://doi.org/10.1007/978-94-009-3307-1_10

Download citation

  • DOI: https://doi.org/10.1007/978-94-009-3307-1_10

  • Publisher Name: Springer, Dordrecht

  • Print ISBN: 978-94-010-7985-3

  • Online ISBN: 978-94-009-3307-1

  • eBook Packages: Springer Book Archive

Publish with us

Policies and ethics