Sutureless thyroidectomy with energy-based devices: Cerrahpasa experience

  • Original Article
  • Published:
Updates in Surgery Aims and scope Submit manuscript

Abstract

Total thyroidectomy makes up the majority of all thyroidectomy cases. Energy-based advanced vessel-sealing devices which were developed in recent years for the control of vascular pedicles allowed significant progress in thyroid surgery. This study is designed to compare the efficiency and safety of the two energy-based vessel-sealing devices (Ligasure™ LF1212 and Harmonic FOCUS®) in sutureless thyroidectomy. Two hundred and forty-five consecutive patients underwent sutureless total thyroidectomy. Patients were randomized for the Ligasure™ LF1212 (n = 126) or Harmonic FOCUS® (n = 119). The parameters of demographics, surgical indications, morbidity, incision length, duration of operation, weight of specimen, amount of drainage, postoperative pain, hospital stay, and histopathology of specimen were recorded. Mean duration of operation was 37.98 ± 14.98 min (16–92 min) and was significantly shorter for Harmonic FOCUS® (p < 0.001). Mean hospital stay was 1.09 ± 0.3 (1–3) days. Morbidity rate was 9.8 % in total, whereas no mortality was observed. In terms of morbidity rates, no significant difference was determined between the two groups (p = 0.476). In both groups, there was no need for extra analgesic application other than the routine given after surgery. According to our experience, sutureless thyroidectomy can be performed with low morbidity rates in secure and efficient way.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Miccoli P, Materazzi G, Miccoli M, Frustaci G, Fosso A, Berti P (2010) Evaluation of a new ultrasonic device in thyroid surgery: comparative randomized study. Am J Surg 199(6):736–740. doi:10.1016/j.amjsurg.2009.04.003

    Article  PubMed  Google Scholar 

  2. Chang LY, O’Neill C, Suliburk J, Sidhu S, Delbridge L, Sywak M (2011) Sutureless total thyroidectomy: a safe and cost-effective alternative. ANZ J Surg 81(7–8):510–514

    Article  PubMed  Google Scholar 

  3. Lombardi CP, Raffaelli M, Cicchetti A, Marchetti M, De Crea C, Di Bidino R, Oragano L, Bellantone R (2008) The use of “harmonic scalpel” versus “knot tying” for conventional “open” thyroidectomy: results of a prospective randomized study. Langenbeck’s archives of surgery/Deutsche Gesellschaft fur Chirurgie 393(5):627–631. doi:10.1007/s00423-008-0380-9

    Article  PubMed  Google Scholar 

  4. Manouras A, Markogiannakis H, Koutras AS, Antonakis PT, Drimousis P, Lagoudianakis EE, Kekis P, Genetzakis M, Koutsoumanis K, Bramis I (2008) Thyroid surgery: comparison between the electrothermal bipolar vessel sealing system, harmonic scalpel, and classic suture ligation. Am J Surg 195(1):48–52. doi:10.1016/j.amjsurg.2007.01.037

    Article  PubMed  Google Scholar 

  5. Youssef T, Mahdy T, Farid M, Latif AA (2008) Thyroid surgery: use of the LigaSure Vessel Sealing System versus conventional knot tying. Int J Surg 6(4):323–327. doi:10.1016/j.ijsu.2008.05.005

    Article  PubMed  Google Scholar 

  6. Sosa JA, Bowman HM, Tielsch JM, Powe NR, Gordon TA, Udelsman R (1998) The importance of surgeon experience for clinical and economic outcomes from thyroidectomy. Ann Surg 228(3):320–330

    Article  PubMed  CAS  Google Scholar 

  7. Dionigi G, Boni L, Rausei S, Frattini F, Ferrari CC, Mangano A, Leotta A, Franchin M (2012) The safety of energy-based devices in open thyroidectomy: a prospective, randomised study comparing the LigaSure (LF1212) and the Harmonic(R) FOCUS. Langenbeck’s archives of surgery/Deutsche Gesellschaft fur Chirurgie 397(5):817–823. doi:10.1007/s00423-011-0898-0

    Article  PubMed  Google Scholar 

  8. Rahbari R, Mathur A, Kitano M, Guerrero M, Shen WT, Duh QY, Clark OH, Kebebew E (2011) Prospective randomized trial of ligasure versus harmonic hemostasis technique in thyroidectomy. Ann Surg Oncol 18(4):1023–1027. doi:10.1245/s10434-010-1251-5

    Article  PubMed  Google Scholar 

  9. Sartori PV, De Fina S, Colombo G, Pugliese F, Romano F, Cesana G, Uggeri F (2008) Ligasure versus Ultracision in thyroid surgery: a prospective randomized study. Langenbeck’s archives of surgery/Deutsche Gesellschaft fur Chirurgie 393(5):655–658. doi:10.1007/s00423-008-0386-3

    Article  PubMed  Google Scholar 

  10. Endosurgery E (2001) Ultracision Harmonic Scalpel user’s manual. Cincinnati

  11. Valleylab C (2010) Ligasure™ Curved, Small Jaw, Open Sealer/Divider (LF1212) user’s manual. Boulder

  12. Rosato L, Avenia N, Bernante P, De Palma M, Gulino G, Nasi PG, Pelizzo MR, Pezzullo L (2004) Complications of thyroid surgery: analysis of a multicentric study on 14,934 patients operated on in Italy over 5 years. World J Surg 28(3):271–276. doi:10.1007/s00268-003-6903-1

    Article  PubMed  Google Scholar 

  13. Pons Y, Gauthier J, Ukkola-Pons E, Clement P, Roguet E, Poncet JL, Conessa C (2009) Comparison of LigaSure vessel sealing system, harmonic scalpel, and conventional hemostasis in total thyroidectomy. Otolaryngol Head Neck Surg: Off J Am Acad Otolaryngol Head Neck Surg 141(4):496–501. doi:10.1016/j.otohns.2009.06.745

    Article  Google Scholar 

  14. Dionigi G, Van Slycke S, Rausei S, Boni L, Dionigi R (2013) Parathyroid function after open thyroidectomy: a prospective randomized study for ligasure precise versus harmonic FOCUS. Head Neck 35(4):562–567. doi:10.1002/hed.23005

    Article  PubMed  Google Scholar 

  15. Barbaros U, Erbil Y, Bozbora A, Deveci U, Aksakal N, Dinccag A, Ozarmagan S (2006) The use of LigaSure in patients with hyperthyroidism. Langenbeck’s archives of surgery/Deutsche Gesellschaft fur Chirurgie 391(6):575–579. doi:10.1007/s00423-006-0082-0

    Article  PubMed  Google Scholar 

  16. Franko J, Kish KJ, Pezzi CM, Pak H, Kukora JS (2006) Safely increasing the efficiency of thyroidectomy using a new bipolar electrosealing device (LigaSure) versus conventional clamp-and-tie technique. Am Surg 72(2):132–136

    PubMed  Google Scholar 

  17. Kirdak T, Korun N, Ozguc H (2005) Use of ligasure in thyroidectomy procedures: results of a prospective comparative study. World J Surg 29(6):771–774. doi:10.1007/s00268-005-7788-y

    Article  PubMed  Google Scholar 

  18. Musunuru S, Schaefer S, Chen H (2008) The use of the Ligasure for hemostasis during thyroid lobectomy. Am J Surg 195(3):382–384. doi:10.1016/j.amjsurg.2007.12.009 discussion 384–385

    Article  PubMed  Google Scholar 

  19. Lachanas VA, Prokopakis EP, Mpenakis AA, Karatzanis AD, Velegrakis GA (2005) The use of Ligasure Vessel Sealing System in thyroid surgery. Otolaryngol Head Neck Surg: Off J Am Acad Otolaryngol Head Neck Surg 132(3):487–489. doi:10.1016/j.otohns.2004.09.020

    Article  Google Scholar 

  20. Miccoli P, Berti P, Dionigi G, D’Agostino J, Orlandini C, Donatini G (2006) Randomized controlled trial of harmonic scalpel use during thyroidectomy. Arch Otolaryngol Head Neck Surg 132(10):1069–1073. doi:10.1001/archotol.132.10.1069

    Article  PubMed  Google Scholar 

  21. Dror A, Salim M, Yoseph R (2003) Sutureless thyroidectomy using electrothermal system: a new technique. J Laryngol Otol 117(3):198–201. doi:10.1258/002221503321192502

    Article  PubMed  Google Scholar 

  22. Defechereux T, Rinken F, Maweja S, Hamoir E, Meurisse M (2003) Evaluation of the ultrasonic dissector in thyroid surgery. A prospective randomised study. Acta Chir Belg 103(3):274–277

    PubMed  Google Scholar 

Download references

Conflict of interest

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Serkan Teksoz.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Teksoz, S., Bukey, Y., Ozcan, M. et al. Sutureless thyroidectomy with energy-based devices: Cerrahpasa experience. Updates Surg 65, 301–307 (2013). https://doi.org/10.1007/s13304-013-0231-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s13304-013-0231-2

Keywords

Navigation