Abstract

The quantitative analysis of upper-extremity motion is a challenging task. A single, universally accepted methodology does not exist, but it is possible to define a standardized way to report a measurement protocol and to formulate recommendations on the most important aspect. The aim of this chapter is to provide such guidelines, addressing common issues such as joint modeling, scapula tracking, soft-tissue artifact compensation, and summary of results.

Keywords

Upper-extremity Shoulder Scapula Elbow Functional axis Motion analysis Kinematics Optoelectronic system Inertial sensors Protocol Measurement methods Scapulo-humeral rhythm Marker-set Coordinate system Anatomical landmarks Functional frames Cluster Skin artifacts 

References

  1. Anglin C, Wyss UP (2000) Review of arm motion analyses. Proc Inst Mech Eng H 214(5):541–555. ReviewCrossRefGoogle Scholar
  2. Barnett ND, Duncan RD, Johnson GR (1999) The measurement of three dimensional scapulohumeral kinematics–a study of reliability. Clin Biomech (Bristol, Avon) 14(4):287–290. PubMed PMID: 10619117Google Scholar
  3. Brochard S, Lempereur M, Rémy-Néris O (2011) Double calibration: an accurate, reliable and easy-to-use method for 3D scapular motion analysis. J Biomech 44(4):751–754CrossRefGoogle Scholar
  4. Campbell AC, Lloyd DG, Alderson JA, Elliott BC (2009) MRI development and validation of two new predictive methods of glenohumeral joint centre location identification and comparison with established techniques. J Biomech 42(10):1527–1532CrossRefGoogle Scholar
  5. Cappozzo A, Cappello A, Della Croce U, Pensalfini F (1997) Surface-marker cluster design criteria for 3-D bone movement reconstruction. IEEE Trans Biomed Eng 44(12):1165–1174. PubMed PMID: 9401217Google Scholar
  6. Cappozzo A, Della Croce U, Leardini A, Chiari L (2005) Human movement analysis using stereophotogrammetry. Part 1: theoretical background. Gait Posture 21(2):186–196Google Scholar
  7. Constant CR, Gerber C, Emery RJ, Sojbjerg JO, Gohlke F, Boileau P (2008) A review of the Constant score: modifications and guidelines for its use. J Shoulder Elbow Surg 17:355–361CrossRefGoogle Scholar
  8. Cutti AG, Veeger HE (2009) Shoulder biomechanics: today’s consensus and tomorrow’s perspectives. Med Biol Eng Comput 47(5):463–466. doi:10.1007/s11517-009-0487-3. PubMed PMID: 19396486Google Scholar
  9. Cutti AG, Paolini G, Troncossi M, Cappello A, Davalli A (2005) Soft tissue artefact assessment in humeral axial rotation. Gait Posture 21(3):341–349CrossRefGoogle Scholar
  10. Cutti AG, Raggi M, Davalli A, Cappello A (2006a) Definition of two reference elbow models from cadaver data. Gait Posture 24S:S224–S225CrossRefGoogle Scholar
  11. Cutti AG, Garofalo P, Davalli A, Cappello A (2006b) How accurate is the estimation of elbow kinematics using ISB recommended joint coordinate systems? Gait Posture 24S:S36–S37CrossRefGoogle Scholar
  12. Cutti AG, Cappello A, Davalli A (2006c) In vivo validation of a new technique that compensates for soft tissue artefact in the upper-arm: preliminary results. Clin Biomech (Bristol, Avon) 21(Suppl 1):S13–S19CrossRefGoogle Scholar
  13. Cutti AG, Giovanardi A, Rocchi L, Davalli A, Sacchetti R (2008) Ambulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors. Med Biol Eng Comput 46(2):169–178CrossRefGoogle Scholar
  14. Cutti AG, Parel I, Raggi M, Petracci E, Pellegrini A, Accardo AP, Sacchetti R, Porcellini G (2014) Prediction bands and intervals for the scapulo-humeral coordination based on the Bootstrap and two Gaussian methods. J Biomech. 47(5):1035–1044CrossRefGoogle Scholar
  15. Cutti AG, Parel I, Pellegrini A, Paladini P, Sacchetti R, Porcellini G, Merolla G (2016) The Constant score and the assessment of scapula dyskinesis: proposal and assessment of an integrated outcome measure. J Electromyogr Kinesiol 29:81–89CrossRefGoogle Scholar
  16. Delp SL, Anderson FC, Arnold AS, Loan P, Habib A, John CT, Guendelman E, Thelen DG (2007) OpenSim: open-source software to create and analyze dynamic simulations of movement. IEEE Trans Biomed Eng 54(11):1940–1950CrossRefGoogle Scholar
  17. Gamage SSHU, Lasenby J (2002) New least squares solutions for estimating the average centre of rotation and the axis of rotation. J Biomech 35(1):87–93CrossRefGoogle Scholar
  18. Garofalo P, Cutti AG, Filippi MV, Cavazza S, Ferrari A, Cappello A et al (2009) Inter-operator reliability and prediction bands of a novel protocol to measure the coordinated movements of shoulder-girdle and humerus in clinical settings. Med Biol Eng Comput 47(5):475–486CrossRefGoogle Scholar
  19. Goto A, Moritomo H, Murase T, Oka K, Sugamoto K, Arimura T, Nakajima Y, Yamazaki T, Sato Y, Tamura S, Yoshikawa H, Ochi T (2004) In vivo elbow biomechanical analysis during flexion: three-dimensional motion analysis using magnetic resonance imaging. J Shoulder Elbow Surg 13(4):441–7. PubMed PMID: 15220886Google Scholar
  20. Halvorsen K, Lesser M, Lundberg A (1999) A new method for estimating the axis of rotation and the center of rotation. J Biomech 32:1221–1227CrossRefGoogle Scholar
  21. Hamming D, Braman JP, Phadke V, LaPrade RF, Ludewig PM (2012) The accuracy of measuring glenohumeral motion with a surface humeral cuff. J Biomech 45(7):1161–1168CrossRefGoogle Scholar
  22. Jaspers E, Feys H, Bruyninckx H, Klingels K, Molenaers G, Desloovere K (2011a) The Arm Profile Score: a new summary index to assess upper limb movement pathology. Gait Posture 34(2):227–233CrossRefGoogle Scholar
  23. Johnson GR, Anderson JM (1990) Measurement of three-dimensional shoulder movement by an electromagnetic sensor. Clin Biomech 5(3):131–136CrossRefGoogle Scholar
  24. Johnson GR, Stuart PR, Mitchell S (1993) A method for the measurement of three-dimensional scapular movement. Clin Biomech (Bristol, Avon) 8(5):269–273. doi: 10.1016/0268-0033(93)90037-I. PubMed PMID: 23915988Google Scholar
  25. Karduna AR, McClure PW, Michener LA (2000) Scapular kinematics: effects of altering the Euler angle sequence of rotations. J Biomech 33(9):1063–1068CrossRefGoogle Scholar
  26. Karduna AR, McClure PW, Michener LA, Sennett B (2001) Dynamic measurement of three-dimensional scapular kinematics: a validation study. J Biomech Eng 123(2):184–190CrossRefGoogle Scholar
  27. Kibler WB, Ludewig PM, McClure PW, Michener LA, Bak K, Sciascia AD (2013) Clinical implications of scapular dyskinesis in shoulder injury: the 2013 consensus statement from the ‘Scapular Summit’. Br J Sports Med 47(14):877–885CrossRefGoogle Scholar
  28. Kontaxis A, Cutti AG, Johnson GR, Veeger HEJ (2009) A framework for the definition of standardized protocols for measuring upper-extremity kinematics. Clin Biomech 24:246–253CrossRefGoogle Scholar
  29. Kontaxis A, Kraszewski A, Gibbsons M, Graziano J, Fealy S, Hillstrom H (2014). Effect of fatigue on high school basebal pitchers, Proceedings of the International Shoulder Group, WaterlooGoogle Scholar
  30. Lempereur M, Leboeuf F, Brochard S, Rousset J, Burdin V, Rémy-Néris O (2010) In vivo estimation of the glenohumeral joint centre by functional methods: accuracy and repeatability assessment. J Biomech 43(2):370–374CrossRefGoogle Scholar
  31. Lempereur M, Brochard S, Rémy-Néris O (2013) Repeatability assessment of functional methods to estimate the glenohumeral joint centre. Comput Methods Biomech Biomed Engin 16(1):6–11CrossRefGoogle Scholar
  32. Lempereur M, Brochard S, Leboeuf F, Rémy-Néris O (2014) Validity and reliability of 3D marker based scapular motion analysis: a systematic review. J Biomech 47(10):2219–2230CrossRefGoogle Scholar
  33. Ludewig PM, Behrens SA, Meyer SM, Spoden SM, Wilson LA (2004) Three dimensional clavicular motion during arm elevation: reliability and descriptive data. J Orthop Sports Phys Ther 34(3):140–149CrossRefGoogle Scholar
  34. Magermans DJ, Chadwick EK, Veeger HE, van der Helm FC (2005) Requirements for upper extremity motions during activities of daily living. Clin Biomech 20(6):591–599CrossRefGoogle Scholar
  35. Marchese SS, Johnson GR (2000) Measuring the kinematics of the clavicle. 6th international symposium of the 3D analysis of human motion, Cape Town, pp 37–40Google Scholar
  36. McGinley JL, Baker R, Wolfe R, Morris ME (2009) The reliability of three-dimensional kinematic gait measurements: a systematic review. Gait Posture 29(3):360–369CrossRefGoogle Scholar
  37. Nikooyan AA, van der Helm FCT, Westerhoff P, Graichen F, Bergmann G, Veeger HEJ (2011) Comparison of two methods for in vivo estimation of the Glenohumeral Joint Rotation Center (GH-JRC) of the patients with shoulder hemiarthroplasty. PLoS One 6(3):e18488CrossRefGoogle Scholar
  38. Parel I, Cutti AG, Fiumana G, Porcellini G, Verni G, Accardo AP (2012) Ambulator measurement of the scapulohumeral rhythm: intra- and inter-operator agreement of a protocol based on inertial and magnetic sensors. Gait Posture 35(4):636–640CrossRefGoogle Scholar
  39. Parel I, Cutti AG, Kraszewski A, Verni G, Hillstrom H, Kontaxis A (2014) Intra-protocol repeatability and inter-protocol agreement for the analysis of scapulo-humeral coordination. Med Biol Eng Comput 52(3):271–282CrossRefGoogle Scholar
  40. Parel I, Jaspers E, DE Baets L, Amoresano A, Cutti AG (2016) Motion analysis of the shoulder in adults: kinematics and electromyography for the clinical practice. Eur J Phys Rehabil Med 52(4):575–582. PubMed PMID: 27434612Google Scholar
  41. Piazza SJ, Cavanagh PR (2000) Measurement of the screw-home motion of the knee is sensitive to errors in axis alignment. J Biomech 33(8):1029–1034CrossRefGoogle Scholar
  42. Prinold JAI, Shaheen AF, Bull AMJ (2011) Skin-fixed scapula trackers: a comparison of two dynamic. J Biomech 44:2004–2007CrossRefGoogle Scholar
  43. Pronk GM, van der Helm FC (1991) The palpator: an instrument for measuring the positions of bones in three dimensions. J Med Eng Technol 15(1):15–20CrossRefGoogle Scholar
  44. Rettig O, Fradet L, Kasten P, Raiss P, Wolf SI (2009) A new kinematic model of the upper extremity based on functional joint parameter determination for shoulder and elbow. Gait Posture 30(4):469–476CrossRefGoogle Scholar
  45. Seth A, Matias R, Veloso AP, Delp SL (2016) A biomechanical model of the scapulothoracic joint to accurately capture scapular kinematics during shoulder movements. PLoS One 11(1):e0141028CrossRefGoogle Scholar
  46. Shaheen AF, Alexander CM, Bull AM (2011) Effects of attachment position and shoulder orientation during calibration on the accuracy of the acromial tracker. J Biomech 44(7):1410–1413CrossRefGoogle Scholar
  47. Stokdijk M, Meskers CG, Veeger HE, de Boer YA, Rozing PM (1999) Determination of the optimal elbow axis for evaluation of placement of prostheses. Clin Biomech 14(3):177–184CrossRefGoogle Scholar
  48. Stokdijk M, Biegstraaten M, Ormel W, de Boer YA, Veeger HE, Rozing PM (2000) Determining the optimal flexion-extension axis of the elbow in vivo - a study of interobserver and intraobserver reliability. J Biomech 33(9):1139–1145. PubMed PMID: 10854888Google Scholar
  49. Teece RM, Lunden JB, Lloyd AS, Kaiser AP, Cieminski CJ, Ludewig PM (2008) Three-dimensional acromioclavicular joint motions during elevation of the arm. J Orthop Sports Phys Ther 38(4):181–190CrossRefGoogle Scholar
  50. van Andel CJ, Wolterbeek N, Doorenbosch CA, Veeger DH, Harlaar J (2008) Complete 3D kinematics of upper extremity functional tasks. Gait Posture 27(1):120–127CrossRefGoogle Scholar
  51. van Andel C, van Hutten K, Eversdijk M, Veeger D, Harlaar J (2009) Recording scapular motion using an acromion marker cluster. Gait Posture 29(1):123–128CrossRefGoogle Scholar
  52. Van der Helm FC, Pronk GM (1995) Three-dimensional recording and description of motions of the shoulder mechanism. J Biomech Eng 117(1):27–40CrossRefGoogle Scholar
  53. Van der Helm FC, Veeger HE, Pronk GM, Van der Woude LH, Rozendal RH (1992) Geometry parameters for musculoskeletal modelling of the shoulder system. J Biomech 25(2):129–144CrossRefGoogle Scholar
  54. van Sint Jan S (2007) Color atlas of skeletal landmark definitions: guidelines for reproducible manual and virtual palpation. Churchill Livingstone, BelgiumGoogle Scholar
  55. Veeger HE, Yu B, An KN, Rozendal RH (1997) Parameters for modeling the upper extremity. J Biomech 30(6):647–652CrossRefGoogle Scholar
  56. Woltring HJ (1990) Data processing and error analysis. In: Cappozzo A, Berme N (eds) Biomechanics of human movement. Bertec Corporation, Worthington, pp 203–237Google Scholar
  57. Wu G, van der Helm FC, Veeger HE, Makhsous M, Van Roy P, Anglin C, Nagels J, Karduna AR, McQuade K, Wang X, Werner FW, Buchholz B (2005) ISB recommendation on definitions of joint CSs of various joints for the reporting of human joint motion – part II: shoulder, elbow, wrist and hand. J Biomech 38(5):981–992CrossRefGoogle Scholar

Copyright information

© Springer International Publishing AG 2017

Authors and Affiliations

  • Andrea Giovanni Cutti
    • 1
  • Ilaria Parel
    • 2
  • Andrea Kotanxis
    • 3
  1. 1.Applied Research, INAIL Prosthetic CenterVigorso di BudrioItaly
  2. 2.Unit of Shoulder and Elbow SurgeryCervesi HospitalCattolicaItaly
  3. 3.Leon Root Motion Analysis LaboratoryHospital for Special SurgeryNew YorkUSA

Personalised recommendations