Table 7 Example of internal reflux from top tray calculation
Stream | V or L | °F | lb/h | Btu/lb | MMBtu/h |
---|---|---|---|---|---|
In | |||||
Int. reflux | V | 222 | x | 1,162 | 1,162x |
Product | V | 222 | 7,506 | 123 | 0.923 |
Total in | 7,506 + x | 0.923 + 1,162x | |||
Out | |||||
Prod | V | 100 | 7,506 | 155.7 | 1.169 |
Reflux | L | 222 | x | 222 | 222x |
Condenser | 8.125 | ||||
Total out | 7,506 + x | 9.294 + 222x |