Abstract
Detectors operated in single-photon-counting mode have radically transformed basic research at synchrotron light sources since 2006. Hybrid photon-counting (HPC) pixel detectors proved to be a disruptive technology for almost all X-ray diffraction applications in the energy range from 2 to 30 keV. The main reason for this success is the accurate determination of scattering and diffraction patterns at the level of individual photons over an extremely high dynamic range.The technology of photon-counting detectors is based on segmented semiconductor sensors, predominantly silicon arrays, which allow direct detection of X-rays and guarantee very high stability and simple operation at room temperature. The sensors are coupled to application-specific integrated circuits (ASICs), which process the electrical signal pulses from the sensor and are designed using modern CMOS processes. The implementation of energy thresholds gives counting detectors the unique capability to determine the number of photons in a specific energy range for very high local and global count rates. The digital detection and storage avoids any readout noise and permits very high frame rates. Combining these features in one device led to a transition from CCD-based detector systems to HPC detectors for applications like protein crystallography, small-angle scattering, and surface and powder diffraction and offers new opportunities in time-resolved experiments.This chapter covers the technology of HPC detectors and their usage at synchrotrons. It describes the basic principles of the sensor, readout ASIC and interconnection technology and highlights the properties of the detectors. In addition details about data correction procedures are given.
Similar content being viewed by others
References
U.W. Arndt, Counting losses of detectors for X-rays from storage rings. J. Phys. E 11, 671–673 (1978)
ATLAS Collaboration, ATLAS detector and physics performance: technical design report, 1 CERN-LHCC-99-014 (1999)
R. Ballabriga, The design and implementation in 0. 13 μm CMOS of an algorithm permitting spectroscopic imaging with high spatial resolution for hybrid pixel detectors. CERN-THESIS-2010-055 (2010)
R. Ballabriga et al., Characterization of the Medipix3 pixel readout chip. J. Instrum. 6, C01052 (2011)
R. Ballabriga et al., The Medipix3RX: a high resolution, zero dead-time pixel detector readout chip allowing spectroscopic imaging. J. Instrum. 8, C02016 (2013)
J.E. Bateman, The effect of beam time structure on counting detectors in SRS experiments. J. Synchrotron Radiat. 7, 307–312 (2000)
M. Battaglia et al., R&D paths of pixel detectors for vertex tracking and radiation imaging (2012). http://arxiv.org/abs/1208.0251
A. Bergamaschi et al., The MYTHEN detector for X-ray powder diffraction experiments at the Swiss Light Source. J. Synchrotron Radiat. 17, 653–668 (2010)
M.J. Berger et al., XCOM: photon cross sections database. NIST, PML, Radiation and Biomolecular Physics Division (1998). http://www.nist.gov/pml/data/xcom. Accessed Aug 2014
C. Broennimann et al., Synchrotron beam test with a photon-counting pixel detector. J. Synchrotron Radiat. 7, 301–306 (2000)
C. Broennimann et al., Continuous sample rotation data collection for protein crystallography with the PILATUS detector. Nucl. Instrum. Meth. A 510, 24–28 (2003)
C. Broennimann et al., The PILATUS 1M detector. J. Synchrotron Radiat. 13, 120–130 (2006)
M. Campbell, 10 years of the Medipix2 collaboration. Nucl. Instrum. Meth. A 633, S1–S10 (2011)
F. Cassol Brunner, First K-edge imaging with a micro-CT based on the XPAD3 hybrid pixel detector. IEEE Trans. Nucl. Sci. 60, 103–108 (2013)
CMS Collaboration, CMS physics: technical design report volume 1: detector performance and software CERN-LHCC-2006-001 (2006)
C.E. Cohn, The effect of deadtime on counting errors. Nucl. Instrum. Meth. 41, 338–340 (1966)
P. Delpierre, Pixels detectors and silicon X-rays detectors. J. Phys. IV 4, C9 11–18 (1994)
P. Delpierre, A history of hybrid pixel detectors, from high energy physics to medical imaging. J. Instrum. 9, C05059 (2014)
R. Dinapoli, A Radiation tolerant pixel detector system for the ALICE and LHCb experiments at CERN. CERN-THESIS-2004-066 (2004)
R. Dinapoli et al., EIGER: next generation single photon counting detector for X-ray applications. Nucl. Instrum. Meth. A 650, 79–83 (2011)
R. Dinapoli et al., EIGER characterization results. Nucl. Instrum. Meth. A 731, 68–73 (2013)
T. Donath et al., Characterization of the PILATUS photon-counting pixel detector for X-ray energies from 1.75 keV to 60 keV. J. Phys. Conf. Ser. 425, 062001 (2013a)
T. Donath et al., Meeting report: workshop on beamline integration and data formatting. Synchrotron Radiat. News 26, 34–35 (2013b)
P. Fischer et al., A counting pixel readout chip for imaging applications. Univ. Physikal. Inst. Bonn 97, 1–10 (1997)
E.N. Gimenez, Characterization of Medipix3 With synchrotron radiation. IEEE Trans. Nucl. Sci. 58, 323–332 (2011)
H. Graafsma, Hybrid pixel array detectors for photon science, in Semiconductor Radiation Detection Systems, ed. by K. Iniewski. CRC, Boca Raton, pp 217–236 (2010)
S.M. Gruner et al., Evaluation of area photon detectors by a method based on detective quantum efficiency (DQE). IEEE Trans. Nucl. Sci. 25, 562–565 (1978)
E.H.M. Heijne et al., The silicon micropattern detector: a dream? Nucl. Instrum. Meth. A 273, 615–619 (1988)
G. HĂ¼lsen et al., Distortion calibration of the PILATUS 1M detector. Nucl. Instrum. Meth. A 548, 540–554 (2005)
P. Kraft et al., Characterization and calibration of PILATUS detectors. IEEE Trans. Nucl. Sci. 56, 758–764 (2009a)
P. Kraft et al., Performance of single-photon-counting PILATUS detector modules. J. Synchrotron Radiat. 16, 368–375 (2009b)
I. Johnson et al., Capturing dynamics with Eiger, a fast-framing X-ray detector. J. Synchrotron Radiat. 19, 1001–1005 (2012)
F. Krummenacher, Pixel detectors with local intelligence: an IC designer point of view. Nucl. Instrum. Meth. A 305, 527–532 (1991)
T. Loeliger et al., The new PILATUS3 ASIC with instant retrigger capability. IEEE Nucl. Sci. Med. Imaging. Conf. R 1, 610–615 (2012)
G. Lutz, Semiconductor Radiation Detectors. Springer, Berlin (1997)
K. Medjoubi et al., Detective quantum efficiency, modulation transfer function and energy resolution comparison between CdTe and silicon sensors bump-bonded to XPAD3S. J. Synchrotron Radiat. 17, 486–495 (2010)
P. Pangaud et al., XPAD3: a new photon counting chip for X-ray CT-scanner. Nucl. Instrum. Meth. A 571, 321–324 (2007)
P. Pangaud et al., XPAD3-S: a fast hybrid pixel readout chip for X-ray synchrotron facilities. Nucl. Instrum. Meth. A 591, 159–162 (2008)
B.R. Pauw, Everything SAXS: small-angle scattering pattern collection and correction. J. Phys. Condens. Matter. 25, 383201 (2013)
D. Pennicard, H. Graafsma, Simulated performance of high-Z detectors with Medipix3 readout. J. Instrum. 6 P06007 (2011)
C. Ponchut, Characterization of X-ray area detectors for synchrotron beamlines. J. Synchrotron Radiat. 13, 195–203 (2005a)
C. Ponchut et al., Experimental comparison of pixel detector arrays and CCD-based systems for X-ray area detection on synchrotron beamlines. IEEE Trans. Nucl. Sci. 52, 1760–1765
G. Potdevin et al., HORUS, an HPAD X-ray detector simulation program. J. Instrum. 4, P09010 (2009)
S. Procz et al., Flatfield correction optimization for energy selective X-ray imaging with Medipix3. IEEE Trans. Nucl. Sci. 58, 3182–3189 (2011)
L. Rossi et al., Pixel Detectors. Springer, Berlin/Heidelberg/New York (2006)
B.A. Sobott et al., Synchrotron radiation hardness studies of PILATUS II. J. Synchrotron Radiat. 16, 489–493 (2009)
A.C. Thompson et al., X-ray data booklet. Center for X-ray optics and Advanced Light Source (2009). http://xdb.lbl.gov. Accessed August 2014
P. Trueb et al., Improved count rate corrections for highest data quality with PILATUS detectors. J. Synchrotron Radiat. 19, 347–351 (2012)
P. Trueb et al., Bunch mode specific rate corrections for PILATUS3 detectors. J. Synchrotron Radiat. (2015, accepted)
A.V. Tyazhev et al., GaAs radiation imaging detectors with an active layer thickness up to 1mm. Nucl. Instrum. Meth. A 509, 34–39 (2003)
M.C. Veale et al., Chromium compensated gallium arsenide detectors for X-ray and γ-ray spectroscopic imaging. Nucl. Instrum. Meth. A 752, 6–14 (2014)
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2015 Springer International Publishing Switzerland
About this entry
Cite this entry
Brönnimann, C., TrĂ¼b, P. (2015). Hybrid Pixel Photon Counting X-Ray Detectors for Synchrotron Radiation. In: Jaeschke, E., Khan, S., Schneider, J., Hastings, J. (eds) Synchrotron Light Sources and Free-Electron Lasers. Springer, Cham. https://doi.org/10.1007/978-3-319-04507-8_36-1
Download citation
DOI: https://doi.org/10.1007/978-3-319-04507-8_36-1
Received:
Accepted:
Published:
Publisher Name: Springer, Cham
Online ISBN: 978-3-319-04507-8
eBook Packages: Springer Reference Physics and AstronomyReference Module Physical and Materials ScienceReference Module Chemistry, Materials and Physics
Publish with us
Chapter history
-
Latest
Hybrid Pixel Photon Counting X-Ray Detectors for Synchrotron Radiation- Published:
- 18 September 2018
DOI: https://doi.org/10.1007/978-3-319-04507-8_36-2
-
Original
Hybrid Pixel Photon Counting X-Ray Detectors for Synchrotron Radiation- Published:
- 25 February 2015
DOI: https://doi.org/10.1007/978-3-319-04507-8_36-1