Skip to main content

Synonyms

T2 – weighted MRI images

Definition

Fractional anisotropy is a method that is used to emphasize and evaluate white matter fiber tracts. This method has been applied to MRI scans in diffusion weighted images. If full tensor data acquisition is applied, the fractional anisotropy (FA) is calculated from the eigenvalues λ1, λ2, and λ3 of the diffusion tensor:

$${\rm FA = }{{\sqrt {3} } \over {\sqrt {2} }}{{\sqrt {{\rm (\lambda }_{1} {\rm - \lambda )}^{2} {\rm + (\lambda}_{2} {\rm - \lambda )}^{2} {\rm + (\lambda }_{3} {\rm - \lambda )}^{2} } } \over {\sqrt {{\rm \lambda }_{1} ^{2} {\rm + \lambda }_{2}^{2} {\rm + \lambda }_{3} ^{2} } }},$$

where λ is the mean diffusivity (trace/3). FA takes on values between 0 (perfectly isotropic diffusion) and 1 (the hypothetical case of an infinite cylinder) and is thus directly comparable between subjects. Here FA is multiplied by 1,000. A fractional process is a procedure that separates mixtures into their components. For example, the total...

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Chapter
USD 29.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 1,350.00
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Hardcover Book
USD 1,299.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References and Readings

  • O’Donnell, L. J., Kubicki, M., Shenton, M. E., Dreusicke, M. H., Grimson, W. E., & Westin, C. F. (2006). A method for clustering white matter fiber tracts. American Journal of Neuroradiology, 27, 1032–1036.

    PubMed  PubMed Central  Google Scholar 

  • Parker, G. J. M. (2004). Analysis of MR diffusion weighted images. The British Journal of Radiology, 77, S176–S185.

    PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 2011 Springer Science+Business Media, LLC

About this entry

Cite this entry

Kaplan, P.E. (2011). Fractional Anisotropy. In: Kreutzer, J.S., DeLuca, J., Caplan, B. (eds) Encyclopedia of Clinical Neuropsychology. Springer, New York, NY. https://doi.org/10.1007/978-0-387-79948-3_32

Download citation

  • DOI: https://doi.org/10.1007/978-0-387-79948-3_32

  • Publisher Name: Springer, New York, NY

  • Print ISBN: 978-0-387-79947-6

  • Online ISBN: 978-0-387-79948-3

  • eBook Packages: Behavioral Science

Publish with us

Policies and ethics