Modelization of Trihalomethanes Formation in Drinking Water Distribution Systems in France

  • Otmane BoudouchEmail author
  • C. Galey
  • C. Rosin
  • A. Zeghnoun
Living reference work entry

Abstract

In France, trihoalomethanes (THM) are regulated and regularly monitored at the water treatment plant and more recently in the drinking water system. THM concentrations at tap water depend on many factors like chlorine level, organic precursor’s concentrations, water temperature, residence time in the network, and presence of rechlorination stations. To predict concentrations in the water distribution system using data collected from treated water at the plant (i.e., the entrance of the distribution system), a first mathematical model was developed in 2009, from three sites supplied by surface water. Predicted concentrations produced with this model for five new sites didn’t match with observed concentrations. New efforts were then made in order to adapt this mathematical model to cover more types of water. Two formulations have been developed: a first model based on a minimum of variables and those easily available (from the French national SISE-Eaux database collecting all data from drinking water regulations) and a second model that includes more information about the reactivity of the organic matter with chlorine. The choice of variables and the general shape of the models were made by dividing the database into two random editions of the couples of data (75% of the data to build the models/25% to validate them). The validation of both models (simplified and complete model) was satisfactory, explaining respectively 87% and 88% of the variance, with a good capacity of generalization. The models developed herein can be used to assess THM concentrations at different points between the treated water at the plant and the consumer’s tap in a large range of French water systems supplied by surface waters.

Keywords

Drinking water Trihalomethanes Chlorine Chlorination byproducts Mathematical model Water distribution system 

References

  1. Azhar S, Sumayya S, Majid M, Mirza MH, Haider AK (2015) Multipathways human health risk assessment of trihalomethane exposure through drinking water. Ecotoxicol Environ Saf 116:129–136CrossRefGoogle Scholar
  2. Davezac H, Grandguillot G, Robin A, Saout C (2008) L’eau potable en France 2005–2006, p 63Google Scholar
  3. Galey C, Zeghnoun A, Boudouch O, Beaudeau P, Rosin C (2015) Modélisation de la formation des trihalométhanes dans les réseaux de distribution d’eau destinés à la consommation humaine en France. Tech Sci Méthodes 6(1):20–31CrossRefGoogle Scholar
  4. Grellier J, Bennett J, Patelarou E, Smith RB, Toledano MB, Rushton L et al (2010) Exposure to disinfection by-products, fetal growth, and prematurity: a systematic review and meta-analysis. Epidemiology 21(3):300–313CrossRefGoogle Scholar
  5. Hwang BF, Jaakkola JJK (2012) Risk of stillbirth in the relation to water disinfection by-products: a population-based case-control study in Taiwan. PLoS One 7(3):e33949CrossRefGoogle Scholar
  6. Levallois P, Gingras S, Marcoux S, Legay C, Catto C, Rodriguez M et al (2012) Maternal exposure to drinking-water chlorination by-products and small-for-gestational-age neonates. Epidemiology 23(2):267–276CrossRefGoogle Scholar
  7. Lewis C, Hoggatt KJ, Ritz B (2011) The impact of different causal models on estimated effects of disinfection by-products on preterm birth. Environ Res 111(3):371–376CrossRefGoogle Scholar
  8. Mouly D, Joulin E, Rosin C, Beaudeau P, Zeghnoun A, Olszewski OA et al (2009) Les sous-produits de chloration dans l’eau destinée à la consommation humaine en France. Campagnes d’analyses dans quatre systèmes de distribution d’eau et modélisation de l’évolution des trihalométhanes. Institut de veille sanitaire, Saint-Maurice, p 73Google Scholar
  9. Mouly D, Joulin E, Rosin C, Beaudeau P, Zeghnoun A, Olszewski OA et al (2010) Variations in trihalomethane levels in three French water distribution systems and the development of a predictive model. Water Res 44(18):5168–5179CrossRefGoogle Scholar
  10. Rahman MB, Driscoll T, Cowie C, Armstrong BK (2010) Disinfection by-products in drinking water and colorectal cancer: a meta-analysis. Int J Epidemiol 39:733–745CrossRefGoogle Scholar
  11. Richardson SD, Plewa MJ, Wagner ED, Schoeny R, Demarini DM (2007) Occurrence, genotoxicity, and carcinogenicity of regulated and emerging disinfection by-products in drinking water: a review and roadmap for research. Mutat Res 636(1-3):178–242CrossRefGoogle Scholar
  12. Villanueva CM, Cantor KP, Grimalt JO, Malats N, Silverman D, Tardon A et al (2007) Bladder cancer and exposure to water disinfection by-products through ingestion, bathing, showering, and swimming in pools. Am J Epidemiol 165(2):148–156CrossRefGoogle Scholar
  13. Weisel CP, Kim H, Haltmeier P, Klotz JB (1999) Exposure estimates to disinfection by-products of chlorinated drinking water. Environ Health Perspect 107(2):103–110CrossRefGoogle Scholar

Copyright information

© Springer International Publishing AG 2018

Authors and Affiliations

  • Otmane Boudouch
    • 1
    Email author
  • C. Galey
    • 3
  • C. Rosin
    • 2
  • A. Zeghnoun
    • 3
  1. 1.Environmental and Agro-Industries Processes TeamUniversity Sultan Moulay SlimaneBeni MellalMorocco
  2. 2.Agence nationale de sécurité sanitaire de l’alimentation, de l’environnement et du travail (Anses) Direction de l’Evaluation des Risques, Unité évaluation des risques liés à l’eauMaisons-Alfort CedexFrance
  3. 3.Agence nationale de santé publique 12 rue du Val d’Osne 94415Saint Maurice CedexFrance

Section editors and affiliations

  • Chaudhery Mustansar Hussain
    • 1
  1. 1.Department of Chemistry and Environmental SciencesNew Jersey Institute of TechnologyNewarkUSA

Personalised recommendations