Skip to main content

Technology of Patch- Clamp Electrodes

  • Protocol
Patch-Clamp Applications and Protocols

Part of the book series: Neuromethods ((NM,volume 26))

Abstract

The extracellular patch voltage clamp technique has allowed the currents through single ionic channels to be studied from a wide variety of cells. In its early form (Neher and Sakmann, 1976), the resolution of this technique was limited by the relatively low (∽50 MΩ) resistances that isolated the interior of the pipet from the bath. The high resolution that presently can be achieved with the patch-clamp technique originated with the discovery (Neher, 1981) that very high-resistance (tens or even hundreds of GΩ) seals can form between the cell membrane and the tip of a clean pipet when gentle suction is applied to the pipet interior. Although the precise mechanisms involved in this membrane-to-glass seal are still not fully understood, the importance of the GΩ seal is obvious. The high resistance of the seal ensures that almost all of the current from the membrane patch flows into the pipet and to the input of the current-sensitive headstage preamplifier. It also allows the small patch of membrane to be voltage-clamped rapidly and accurately via the pipet, and the mechanical stability of the seal is vital to the whole-cell voltage clamp technique.

This is a preview of subscription content, log in via an institution to check access.

Access this chapter

Protocol
USD 49.95
Price excludes VAT (USA)
  • Available as PDF
  • Read on any device
  • Instant download
  • Own it forever
eBook
USD 84.99
Price excludes VAT (USA)
  • Available as EPUB and PDF
  • Read on any device
  • Instant download
  • Own it forever
Softcover Book
USD 109.99
Price excludes VAT (USA)
  • Compact, lightweight edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info
Hardcover Book
USD 109.99
Price excludes VAT (USA)
  • Durable hardcover edition
  • Dispatched in 3 to 5 business days
  • Free shipping worldwide - see info

Tax calculation will be finalised at checkout

Purchases are for personal use only

Institutional subscriptions

References

  • Hamill P., Marty A., Neher E., Sakman B., and Sigworth F. J. (1981) Improved patch-clamp techniques for high-resolution current recording from cells and cell-free membrane patches. Pflügers Arch. 391, 85–100.

    Article  PubMed  CAS  Google Scholar 

  • Levis R. A. and Rae J. L. (1992) Constructing a patch-clamp setup. Meth. Enzymol. 207, 18–66.

    Google Scholar 

  • Levis R. A. and Rae J. L. (1993) The use of quartz patch pipettes for low noise single channel recording. Biophys. J. 65, 1666–1677.

    Article  PubMed  CAS  Google Scholar 

  • Neher E. (1981) Unit conductance studies in biological membranes. Techniques in Cellular Physiology (Baker, P. F., ed.), Elsevier, North Holland, Amsterdam.

    Google Scholar 

  • Neher E. and Sakman B. (1976) Single channel currents recorded from membrane of denervated frog muscle fibers. Nature (bond.) 260, 799–802.

    Article  CAS  Google Scholar 

  • Rae J. L. and Levis R. A. (1984) Patch voltage clamp of lens epithelial cells: theory and practice. Mol. Physiol. 6, 115–162.

    CAS  Google Scholar 

  • Rae J. L. and Levis R. A. (1992a) Glass technology for patch electrodes. Meth. Enzymol. 207, 66–92.

    Article  PubMed  CAS  Google Scholar 

  • Rae J. L. and Levis R. A. (1992b) A method for exceptionally low noise single channel recordings. Pflügers Arch. 42, 618–620.

    Article  Google Scholar 

  • Sakmann B. and Neher E. (1983) Geometric parameters of pipettes and membrane patches, in Single-Channel Recording (Sakmann B. and Neher E., eds.), Plenum, New York, pp. 37–51.

    Chapter  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Editor information

Editors and Affiliations

Rights and permissions

Reprints and permissions

Copyright information

© 1995 The Humana Press Inc.

About this protocol

Cite this protocol

Levis, R.A., Rae, J.L. (1995). Technology of Patch- Clamp Electrodes. In: Boulton, A.A., Baker, G.B., Walz, W. (eds) Patch-Clamp Applications and Protocols. Neuromethods, vol 26. Humana Press, Totowa, NJ. https://doi.org/10.1385/0-89603-311-2:1

Download citation

  • DOI: https://doi.org/10.1385/0-89603-311-2:1

  • Publisher Name: Humana Press, Totowa, NJ

  • Print ISBN: 978-0-89603-311-5

  • Online ISBN: 978-1-59259-631-7

  • eBook Packages: Springer Protocols

Publish with us

Policies and ethics