Abstract
Reference ranges are a set of values that correctly include most of the subjects with characteristics similar to the reference group and exclude the others. When accurate, reference ranges aid physicians to interpret results of clinical measurements and thus establish diagnosis. However, obtaining accurate reference ranges is a very demanding procedure. This chapter provides basic definitions and theories as well as a step-by-step procedure for the analysis of reference values and determination of reference ranges of coagulation, focusing on quantitative clinical laboratory assays. Preanalytical and analytical factors as well as dependence on the age influencing reference values for coagulation assays and their transference are discussed.
This is a preview of subscription content, log in via an institution.
Buying options
Tax calculation will be finalised at checkout
Purchases are for personal use only
Learn about institutional subscriptionsReferences
Schneider AJ (1960) Some thoughts on normal, or standard, values in clinical medicine. Pediatrics 26:973–984
Horn PS, Pesce AJ, Copeland BE (1998) A robust approach to reference interval estimation and evaluation. Clin Chem 44:622–631
Solberg HE (1987) International Federation of Clinical Chemistry (IFCC), Scientific Committee, Clinical Section, Expert Panel on Theory of Reference Values, and International Committee for Standardization in Haematology (ICSH), Standing Committee on Reference Values. Approved Recommendation (1986) on the theory of reference values. Part 1. The concept of reference values. J Clin Chem Clin Biochem 25:337–342
PetitClerc C, Wilding P (1984) International Federation of Clinical Chemistry (IFCC), Scientific Committee, Clinical Section. The theory of reference values. Part 2. Selection of individuals for the production of reference values. J Clin Chem Clin Biochem 22:203–208
Solberg HE, PetitClerc C (1988) International Federation of Clinical Chemistry (IFCC), Scientific Committee, Clinical Section, Expert Panel on Theory of Reference Values. Approved recommendation (1988) on the theory of reference values. Part 3. Preparation of individuals and collection of specimens for the production of reference values. J Clin Chem Clin Biochem 26:593–598
Solberg HE, Stamm D (1991) International Federation of Clinical Chemistry IFCC. IFCC recommendation—theory of reference values. Part 4. Control of analytical variation in the production, transfer and application of reverence values. Clin Chim Acta 202:S5–S11
Solberg HE (1987) International Federation of Clinical Chemistry (IFCC), Scientific Committee, Clinical Section, Expert Panel on Theory of Reference Values, and International Committee for Standardization in Haematology (ICSH), Standing Committee on Reference Values. Approved Recommendation (1986) on the theory of reference values. Part 5. Statistical treatment of collected reference values. Determination of reference limits. Clin Chim Acta 170:S13–S32
Solberg HE (1987) International Federation of Clinical Chemistry (IFCC), Scientific Committee, Clinical Section, Expert Panel on Theory of Reference Values, and International Committee for Standardization in Haematology (ICSH), Standing Committee on Reference Values. Approved Recommendation (1986) on the theory of reference values. Part 6. Presentation of observed values related to reference values. Clin Chim Acta 170:S33–S42
(1981) The theory of reference values: international committee for standardization in haematology (ICSH). Clin Lab Haematol 3:369–373
(1982) Standardization of blood specimen collection procedure for reference values. International Committee for Standardization in Haematology (ICSH). Clin Lab Haematol 4:83–86
(1984) Recommendation for a selected method for the measurement of plasma viscosity. International Committee for Standardization in Haematology. J Clin Pathol 37:1147–1152
(1988) The assignment of values to fresh blood used for calibrating automated blood cell counters. International Committee for Standardization in Haematology; Expert Panel on Cytometry. Clin Lab Haematol 10:203–212
(1989) Recommended methods for an additional red cell enzyme (pyrimidine 5′-nucleotidase) assay and the determination of red cell adenosine-5′-triphosphate, 2,3-diphosphoglycerate and reduced glutathione. International Committee for Standardization in Haematology. Clin Lab Haematol 11:131–138
(1990) ICSH recommendations for the analysis of red cell, white cell and platelet size distribution curves. Methods for fitting a single reference distribution and assessing its goodness of fit. International Committee for Standardization in Haematology. ICSH Expert Panel on Cytometry. Clin Lab Haematol 12: 417–431
(1993) ICSH recommendations for measurement of erythrocyte sedimentation rate. International Council for Standardization in Haematology (Expert Panel on Blood Rheology). J Clin Pathol 46:198–203
(1993) Recommendations of the International Council for Standardization in Haematology for ethylenediaminetetraacetic acid anticoagulation of blood for blood cell counting and sizing. International Council for Standardization in Haematology: Expert Panel on Cytometry. Am J Clin Pathol 100:371–372
(1994) Reference method for the enumeration of erythrocytes and leucocytes. International Council for Standardization in Haematology; prepared by the Expert Panel on Cytometry. Clin Lab Haematol 16:131–138
(1994) Guidelines for the evaluation of blood cell analysers including those used for differential leucocyte and reticulocyte counting and cell marker applications. International Council for Standardization in Haematology: prepared by the ICSH Expert Panel on Cytometry. Clin Lab Haematol 16:157–174
(1998) Proposed reference method for reticulocyte counting based on the determination of the reticulocyte to red cell ratio. The Expert Panel on Cytometry of the International Council for Standardization in Haematology. Clin Lab Haematol 20:77–79
NCCLS (2000) How to define and determine reference intervals in the clinical laboratory. Approved Guideline, 2nd edn. NCCLS Document C28-A2, Wayne
Henny J, Petitclerc C, Fuentes-Arderiu X, Petersen PH, Queralto JM, Schiele F, Siest G (2000) Need for revisiting the concept of reference values. Clin Chem Lab Med 38:589–595
Goldschmidt HM (2004) The NEXUS vision: an alternative to the reference value concept. Clin Chem Lab Med 42:868–873
Henny J, Hyltoft Petersen P (2004) Reference values: from philosophy to a tool for laboratory medicine. Clin Chem Lab Med 42:686–691
Grasbeck R (2004) The evolution of the reference value concept. Clin Chem Lab Med 42:692–697
Petitclerc C (2004) Normality: the unreachable star? Clin Chem Lab Med 42:698–701
Ritchie RF, Palomaki G (2004) Selecting clinically relevant populations for reference intervals. Clin Chem Lab Med 42:702–709
Solberg HE (2004) The IFCC recommendation on estimation of reference intervals. The RefVal program. Clin Chem Lab Med 42:710–714
Hyltoft Petersen P, Blaabjerg O, Andersen M, Jorgensen LG, Schousboe K, Jensen E (2004) Graphical interpretation of confidence curves in rankit plots. Clin Chem Lab Med 42:715–724
Lahti A (2004) Partitioning biochemical reference data into subgroups: comparison of existing methods. Clin Chem Lab Med 42:725–733
Virtanen A, Kairisto V, Uusipaikka E (2004) Parametric methods for estimating covariate-dependent reference limits. Clin Chem Lab Med 42:734–738
Boyd JC (2004) Reference regions of two or more dimensions. Clin Chem Lab Med 42:739–746
Jorgensen LG, Brandslund I, Hyltoft Petersen P (2004) Should we maintain the 95 percent reference intervals in the era of wellness testing? A concept paper. Clin Chem Lab Med 42:747–751
Klee GG (2004) Clinical interpretation of reference intervals and reference limits. A plea for assay harmonization. Clin Chem Lab Med 42:752–757
Fraser CG (2004) Inherent biological variation and reference values. Clin Chem Lab Med 42:758–764
Queralto JM (2004) Intraindividual reference values. Clin Chem Lab Med 42:765–777
Fuentes-Arderiu X, Mas-Serra R, Aluma-Trullas A, Marti-Marcet MI, Dot-Bach D (2004) Guideline for the production of multicentre physiological reference values using the same measurement system. A proposal of the Catalan Association for Clinical Laboratory Sciences. Clin Chem Lab Med 42:778–782
Rustad P, Felding P, Lahti A (2004) Proposal for guidelines to establish common biological reference intervals in large geographical areas for biochemical quantities measured frequently in serum and plasma. Clin Chem Lab Med 42:783–791
Johnson AM, Hyltoft Petersen P, Whicher JT, Carlstrom A, MacLennan S (2004) Reference intervals for serum proteins: similarities and differences between adult Caucasian and Asian Indian males in Yorkshire, UK. Clin Chem Lab Med 42:792–799
Ichihara K, Itoh Y, Min WK, Yap SF, Lam CW, Kong XT, Chou CT, Nakamura H (2004) Diagnostic and epidemiological implications of regional differences in serum concentrations of proteins observed in six Asian cities. Clin Chem Lab Med 42:800–809
Siest G (2004) Study of reference values and biological variation: a necessity and a model for Preventive Medicine Centers. Clin Chem Lab Med 42:810–816
Jorgensen LG, Brandslund I, Hyltoft Petersen P, Stahl M, de Fine Olivarius N (2004) Creation of a low-risk reference group and reference interval of fasting venous plasma glucose. Clin Chem Lab Med 42:817–823
Jensen E, Hyltoft Petersen P, Blaabjerg O, Hansen PS, Brix TH, Kyvik KO, Hegedus L (2004) Establishment of a serum thyroid stimulating hormone (TSH) reference interval in healthy adults. The importance of environmental factors, including thyroid antibodies. Clin Chem Lab Med 42:824–832
Dhondt JL (2004) Difficulties in establishing reference intervals for special fluids: the example of 5-hydroxyindoleacetic acid and homovanillic acid in cerebrospinal fluid. Clin Chem Lab Med 42:833–841
Thienpont LM, Van Uytfanghe K, Rodriguez Cabaleiro D (2004) Metrological traceability of calibration in the estimation and use of common medical decision-making criteria. Clin Chem Lab Med 42:842–850
Klein G, Junge W (2004) Creation of the necessary analytical quality for generating and using reference intervals. Clin Chem Lab Med 42:851–857
Ricos C, Domenech MV, Perich C (2004) Analytical quality specifications for common reference intervals. Clin Chem Lab Med 42:858–862
Westgard JO (2004) Design of internal quality control for reference value studies. Clin Chem Lab Med 42:863–867
WHO (2006) Constitution of the World Health Organization. Basic Documents, 45th edn, 1
NCCLS (2004) Procedures and devices for the collection of diagnostic capillary blood specimens. Approved Standard, 5th edn. NCCLS Document H04-A5, Wayne
NCCLS (2007) Procedures for the collection of diagnostic blood specimens by venipuncture. Approved Standard, 6th edn. NCCLS Document H03-A6, Wayne
Andrew M, Paes B, Milner R, Johnston M, Mitchell L, Tollefsen DM, Powers P (1987) Development of the human coagulation system in the full-term infant. Blood 70:165–172
Andrew M, Vegh P, Johnston M, Bowker J, Ofosu F, Mitchell L (1992) Maturation of the hemostatic system during childhood. Blood 80:1998–2005
Hathaway W, Corrigan J (1991) Report of Scientific and Standardization Subcommittee on Neonatal Hemostasis. Normal coagulation data for fetuses and newborn infants. Thromb Haemost 65:323–325
Schmidt B, Mitchell L, Ofosu FA, Andrew M (1989) Alpha-2-macroglobulin is an important progressive inhibitor of thrombin in neonatal and infant plasma. Thromb Haemost 62:1074–1077
Albisetti M (2003) The fibrinolytic system in children. Semin Thromb Hemost 29:339–348
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Humana Press
About this protocol
Cite this protocol
Speer, O., Schmugge, M., Metzger, C., Albisetti, M. (2013). Reference Ranges of Coagulation Tests. In: Monagle, P. (eds) Haemostasis. Methods in Molecular Biology, vol 992. Humana Press, Totowa, NJ. https://doi.org/10.1007/978-1-62703-339-8_6
Download citation
DOI: https://doi.org/10.1007/978-1-62703-339-8_6
Published:
Publisher Name: Humana Press, Totowa, NJ
Print ISBN: 978-1-62703-338-1
Online ISBN: 978-1-62703-339-8
eBook Packages: Springer Protocols