Abstract
Despite considerable advances in the safety of blood components based on the application of highly sensitive and specific screening methods to minimize the viral infection risk, the prevention of transfusion-associated bacterial infection remains a major challenge in transfusion medicine. In particular, platelet concentrates represent the greatest infectious risk of transfusion-transmitted bacterial sepsis. The detection of bacterial contamination in platelet concentrates has been implemented in several blood services as a routine quality control testing. Although culture is likely to remain the gold standard method of detecting bacterial contamination, the use of rapid methods is likely to increase and play an important role in transfusion medicine in the future. In particular, flow cytometric methods and nucleic acid amplification techniques are powerful tools in bacterial screening assays. Compared to culture-based methods, the combination of high sensitivity and specificity, low contamination risk, ease of performance, and speed has made those technologies appealing alternatives to conventional culture-based testing methods.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
Similar content being viewed by others
References
Wagner SJ, Friedman LI, Dodd RY (1994) Transfusion-associated bacterial sepsis. Clin Microbiol Rev 7:290–302
Brecher ME, Hay SN (2005) Bacterial contamination of blood components. Clin Microbiol Rev 18:195–204
Reading FC, Brecher ME (2001) Transfusion-related bacterial sepsis. Curr Opin Hematol 8:380–386
Blajchman MA, Goldman M, Baeza F (2004) Improving the bacteriological safety of platelet transfusions. Transfus Med Rev 18:11–24
Montag T (2006) Perspectives and limitations in the bacterial screening of platelet concentrates. J Lab Med 30:60–65
te Boekhorst PA, Beckers EA, Vos MC, Vermeij H, van Rhenen DJ (2005) Clinical significance of bacteriologic screening in platelet concentrates. Transfusion 45:514–519
Walther-Wenke G (2006) Bacterial contamination of blood components-incidence and significance for homologous and autologous transfusion. J Lab Med 30:66–73
Dreier J, Störmer M, Pichl L, Schottstedt V, Grolle A, Bux J, Kleesiek K (2008) Sterility screening of platelet concentrates: questioning the optimal test strategy. Vox Sang 95: 181–188
Mohammadi T, Savelkoul PH, Pietersz RN, Reesink HW (2006) Applications of real-time PCR in the screening of platelet concentrates for bacterial contamination. Expert Rev Mol Diagn 6:865–872
Rood IG, Koppelman MH, Pettersson A, Savelkoul PH (2008) Development of an internally controlled PCR assay for broad range detection of bacteria in platelet concentrates. J Microbiol Methods 75:64–69
Karo O, Wahl A, Nicol SB, Brachert J, Lambrecht B, Spengler HP, Nauwelaers F, Schmidt M, Schneider CK, Muller TH, Montag T (2008) Bacteria detection by flow cytometry. Clin Chem Lab Med 46:947–953
Mohr H, Lambrecht B, Bayer A, Spengler HP, Nicol SB, Montag T, Muller TH (2006) Basics of flow cytometry-based sterility testing of platelet concentrates. Transfusion 46:41–49
Schmidt M, Hourfar MK, Nicol SB, Spengler HP, Montag T, Seifried E (2006) FACS technology used in a new rapid bacterial detection method. Transfus Med 16:355–361
Schmidt M, Karakassopoulos A, Burkhart J, Deitenbeck R, Asmus J, Muller TH, Weinauer F, Seifried E, Walther-Wenke G (2007) Comparison of three bacterial detection methods under routine conditions. Vox Sang 92:15–21
Dreier J, Vollmer T, Kleesiek K (2009) Novel flow cytometry-based screening for bacterial contamination of donor platelet preparations compared with other rapid screening methods. Clin Chem 55:1492–1502
Palavecino EL, Yomtovian RA, Jacobs MR (2006) Detecting bacterial contamination in platelet products. Clin Lab 52:443–456
Prowse C (2007) Zero tolerance. Transfusion 47:1106–1109
Störmer M, Kleesiek K, Dreier J (2007) High-volume extraction of nucleic acids by magnetic bead technology for ultrasensitive detection of bacteria in blood components. Clin Chem 53:104–110
Kleines M, Schellenberg K, Ritter K (2003) Efficient extraction of viral DNA and viral RNA by the Chemagic viral DNA/RNA kit allows sensitive detection of cytomegalovirus, hepatitis B virus, and hepatitis G virus by PCR. J Clin Microbiol 41:5273–5276
Marin M, Munoz P, Sanchez M, del Rosal M, Alcala L, Rodriguez-Creixems M, Bouza E (2007) Molecular diagnosis of infective endocarditis by real-time broad-range polymerase chain reaction (PCR) and sequencing directly from heart valve tissue. Medicine (Baltimore) 86:195–202
Dreier J, Störmer M, Kleesiek K (2007) Real-time polymerase chain reaction in transfusion medicine: applications for detection of bacterial contamination in blood products. Transfus Med Rev 21:237–254
Watzinger F, Ebner K, Lion T (2006) Detection and monitoring of virus infections by real-time PCR. Mol Aspects Med 27:254–298
Dreier J, Störmer M, Kleesiek K (2004) Two novel real-time reverse transcriptase PCR assays for rapid detection of bacterial contamination in platelet concentrates. J Clin Microbiol 42:4759–4764
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2013 Springer Science+Business Media, LLC
About this protocol
Cite this protocol
Vollmer, T., Kleesiek, K., Dreier, J. (2013). Detection of Bacterial Contamination in Platelet Concentrates Using Flow Cytometry and Real-Time PCR Methods. In: Wilks, M. (eds) PCR Detection of Microbial Pathogens. Methods in Molecular Biology, vol 943. Humana Press, Totowa, NJ. https://doi.org/10.1007/978-1-60327-353-4_5
Download citation
DOI: https://doi.org/10.1007/978-1-60327-353-4_5
Published:
Publisher Name: Humana Press, Totowa, NJ
Print ISBN: 978-1-60327-352-7
Online ISBN: 978-1-60327-353-4
eBook Packages: Springer Protocols