Abstract
Intracellular cytokine staining is a versatile technique used to analyze cytokine production in individual cells by flow cytometry. This methodology has the specific advantage of enabling the simultaneous assessment of multiple phenotypic, differentiation, and functional parameters pertaining to responding T cells. This methodology applied after short-term culture of cells, followed by fixation and permeabilization make this technique ideal for the assessment of T-cell immune responses induced by different challenges. Here we describe an intracellular staining method followed by flow cytometry after cell stimulation with immune-relevant antigens for Lyme disease.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Horton H, Thomas EP, Stucky JA et al (2007) Optimization and validation of an 8-color intracellular cytokine staining (ICS) assay to quantify antigen-specific T cells induced by vaccination. J Immunol Methods 323(1):39–54. https://doi.org/10.1016/j.jim.2007.03.002
Foote JB, Sarvesh S, Emens LA (2020) Cytokine profiling of tumor-infiltrating T lymphocytes by flow cytometry. Methods Enzymol 631:1–20. https://doi.org/10.1016/bs.mie.2019.08.015
Maecker HT, Rinfret A, D'Souza P et al (2005) Standardization of cytokine flow cytometry assays. BMC Immunol 6:13. https://doi.org/10.1186/1471-2172-6-13
Smith SG, Smits K, Joosten SA et al (2015) Intracellular cytokine staining and flow cytometry: considerations for application in clinical trials of novel tuberculosis vaccines. PLoS One 10(9):e0138042. https://doi.org/10.1371/journal.pone.0138042
Lamoreaux L, Roederer M, Koup R (2006) Intracellular cytokine optimization and standard operating procedure. Nat Protoc 1(3):1507–1516. https://doi.org/10.1038/nprot.2006.268
Zuo J, Dowell AC, Pearce H et al (2021) Robust SARS-CoV-2-specific T cell immunity is maintained at 6 months following primary infection. Nat Immunol 22(5):620–626. https://doi.org/10.1038/s41590-021-00902-8
Maecker HT, Dunn HS, Suni MA et al (2001) Use of overlapping peptide mixtures as antigens for cytokine flow cytometry. J Immunol Meth 255(1–2):27–40. https://doi.org/10.1016/s0022-1759(01)00416-1
Tesfa L, Koch FW, Pankow W et al (2004) Confirmation of mycobacterium tuberculosis infection by flow cytometry after ex vivo incubation of peripheral blood T cells with an ESAT-6-derived peptide pool. Cytometry B Clin Cytom 60(1):47–53. https://doi.org/10.1002/cyto.b.20007
Mascher B, Schlenke P, Seyfarth M (1999) Expression and kinetics of cytokines determined by intracellular staining using flow cytometry. J Immunol Meth. 223(1):115–121. https://doi.org/10.1016/s0022-1759(98)00200-2
Author information
Authors and Affiliations
Corresponding author
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2024 The Author(s), under exclusive license to Springer Science+Business Media, LLC, part of Springer Nature
About this protocol
Cite this protocol
Calderilla-Barbosa, L., Flores-Sevilla, J.L. (2024). CYTOSPOT: Intracellular Staining and Detection of Cytokines by Flow Cytometer, an Alternative to LYMESPOT. In: Gilbert, L. (eds) Borrelia burgdorferi. Methods in Molecular Biology, vol 2742. Humana, New York, NY. https://doi.org/10.1007/978-1-0716-3561-2_7
Download citation
DOI: https://doi.org/10.1007/978-1-0716-3561-2_7
Published:
Publisher Name: Humana, New York, NY
Print ISBN: 978-1-0716-3560-5
Online ISBN: 978-1-0716-3561-2
eBook Packages: Springer Protocols