Matrix-Assisted Laser Desorption Ionization Mass Spectrometry as a Complement to Internal Protein Sequencing

  • Kenneth R. Williams
  • Suzy M. Samandar
  • Kathryn L. Stone
  • Melissa Saylor
  • John Rush

Abstract

Matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS) is a relatively new mass-analysis method suitable for the analysis of biological molecules (1, 2, 3). Compared to other mass-analysis methods, MALDI-MS is based on simpler instrumentation that is more easily operated and so is more readily accessible to laboratories without prior experience in mass spectrometry. In addition, the method is sensitive and capable of high throughput. Its use in biochemical laboratories is already widespread, despite its recent introduction and the continued development of MALDI-MS instrumentation and applications.

Keywords

Tryptic Peptide Mass Accuracy Internal Sequencing Laser Desorption Ionization Mass Spectrometry Peptide Purity 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

References

  1. 1.
    Hillenkamp, F., Karas, M., Beavis, R., and Chait, B. (1991) Matrix-assisted laser desorption/ionization mass spectrometry of biopolymers. Anal. Chem. 63, 1193–1202.CrossRefGoogle Scholar
  2. 2.
    Cotter, R. J. (1992) Time-of-flight mass spectrometry for the structural analysis of biological molecules. Anal. Chem. 64, 1027–1039.CrossRefGoogle Scholar
  3. 3.
    Chait, B. T. and Kent, S. H. (1992) Weighing naked proteins: practical, high-accuracy mass measurements of peptides and proteins. Science 257, 1885–1894.PubMedCrossRefGoogle Scholar
  4. 4.
    Brown, J. L. and Roberts, W. K. (1976) Evidence that approximately eighty percent of the soluble proteins from Ehrlich Asites cells are amino terminally acetylated. J. Biol. Chem. 251, 1009–1014.PubMedGoogle Scholar
  5. 5.
    Driessen, H. P., De Jong, W. W., Tesser, G. I., and Bloemendal, H. (1985) The mechanism of N-termimal acetylation of proteins, in Critical Reviews in Biochemistry, vol. 8 (Fasman, G. D., ed.), CRC, Boca Raton, FL, pp. 281–325.Google Scholar
  6. 6.
    Rosenfeld, J., Capdeville, J., Guillemot, J., and Ferrara, P. (1992) In-gel digestions of proteins for internal sequence analysis after 1 or 2 dimensional gel electrophoresis. Anal. Biochem. 203, 173–179.PubMedCrossRefGoogle Scholar
  7. 7.
    Williams, K. R. and Stone, K. S. (1995) In-gel digestion of SDS PAGE-separated proteins: observations from internal sequencing of 25 proteins, in Techniques in Protein Chemistry VI (Crabb, J., ed.), Academic, San Diego, pp. 143–152.CrossRefGoogle Scholar
  8. 8.
    Stone, K. L., McNulty, D. E., LoPresti, M. L., Crawford, J. M., DeAngelis, R., and Williams, K. R. (1992) Elution and internal amino acid sequencing of PVDF-blotted proteins, in Techniques in Protein Chemistry III (Angeletti, R., ed.), Academic, New York, pp. 22–34.Google Scholar
  9. 9.
    Williams, K. R., Kobayashi, R., Lane, W., and Tempst, P. (1993) Internal amino acid sequencing: observations from four different laboratories. ABRF News 4, 7–12.Google Scholar
  10. 10.
    Stone, K. L. and Williams, K. R. (1993) Enzymatic digestion of proteins and HPLC peptide isolation, in A Practical Guide to Protein and Peptide Purification for Microsequencing (Matsudaira, P. T., ed.), Academic, New York, pp. 43–69.Google Scholar
  11. 11.
    Elliott, J. I., Stone, K. L., and Williams, K. R. (1993) Synthesis and use of an internal amino acid sequencing standard peptide. Anal. Biochem. 211, 94–101.PubMedCrossRefGoogle Scholar
  12. 12.
    Henzel, W. J., Billed, T. M., Stults, J. T., Wong, S. C., Grimley, C., and Watanabe, C. (1993) Identifying proteins from two-dimensional gels by molecular mass searching of peptide fragments in protein sequence databases. Proc. Natl. Acad. Sci. USA 90, 5011–5015.PubMedCrossRefGoogle Scholar
  13. 13.
    Williams, K. R. and Carr, S. A. (1995) Protein analysis by integrated sample preparation, chemistry, and mass spectrometry, in Encyclopedia of Molecular Biology and Biotechnology (Meyers, R. A., ed.), VCH Publishers, New York, pp. 731–737.Google Scholar
  14. 14.
    Bornsen, K. O., Schar, M., Gassman, E., and Steiner, V. (1991) Analytical applications of matrix-assisted laser desorption ionization mass spectrometry. Biol. Mass. Spectrom. 20, 471–478.CrossRefGoogle Scholar
  15. 15.
    Germanos, S., Casteels, P., Elicone, C., Powell, M., and Tempst, P. (1994) Combined Edman-chemical and laser-desorption mass spectrometric approaches to micro peptide sequencing: optimization and applications, in Techniques in Protein Chemistry V (Crabb, J. W., ed.), Academic, New York, pp. 143–150.Google Scholar
  16. 16.
    Mann, M., Horup, P., and Roepstorff, P. (1993) Use of mass spectrometric molecular weight information to identify proteins in sequence databases. Biol. Mass. Spectrom. 22, 338–345.PubMedCrossRefGoogle Scholar

Copyright information

© Humana Press Inc., Totowa, NJ 1996

Authors and Affiliations

  • Kenneth R. Williams
    • 1
  • Suzy M. Samandar
    • 1
  • Kathryn L. Stone
    • 1
  • Melissa Saylor
    • 1
  • John Rush
    • 1
  1. 1.Biotechnology Resource LaboratoryYale UniversityNew Haven

Personalised recommendations