Advertisement

Microchip-Based Electrophoretic Separations with a Pressure-Driven Backflow

  • Ling Xia
  • Debashis DuttaEmail author
Protocol
Part of the Methods in Molecular Biology book series (MIMB, volume 1906)

Abstract

It is well known that the resolving power of capillary zone electrophoretic separations may be improved with an increase in the applied electric field strength and separation time. While large electric fields may be realized in short analysis channels commonly employed in microfluidic systems, this experimental design is not suitable for achieving long separation times. In this chapter, we describe the use of a steady and/or a periodic pressure-driven backflow to increase the separation time in short microchannels thereby enabling the analysis of closely related species on microchip devices. The reported backflow was realized in our assays using an on-chip pressure-generation capability that relied on the partial blockage of electroosmotic flow around a junction of two glass channel segments having different depths. Although the noted strategy led to additional band broadening in the system, the resolving power of our device was observed to substantially improve upon introduction of the reported steady/periodic pressure-driven backflow for analysis channels shallower than 5 μm.

Key words

Band broadening Capillary zone electrophoresis Electroosmosis Microfluidic pump Pressure-driven backflow 

References

  1. 1.
    Jorgenson JW, Lukacs KD (1981) Capillary zone electrophoresis. Science 222:266–272CrossRefGoogle Scholar
  2. 2.
    Polson NA, Hayes MA (2000) Electroosmotic flow control of fluids on a capillary electrophoresis microdevice using an applied external voltage. Anal Chem 72:1088–1092CrossRefGoogle Scholar
  3. 3.
    Xia L, Dutta D (2012) A microchip device for enhancing capillary zone electrophoresis using pressure-driven backflow. Anal Chem 84:10058–10063CrossRefGoogle Scholar
  4. 4.
    Culbertson CT, Jorgenson JW (1994) Flow counterbalanced capillary electrophoresis. Anal Chem 66(7):955–962CrossRefGoogle Scholar
  5. 5.
    Xia L, Dutta D (2013) Microfluidic flow counterbalanced capillary electrophoresis. Analyst 138:2126–2133CrossRefGoogle Scholar
  6. 6.
    Taylor GI (1953) Dispersion of soluble matter in solvent flowing slowly through a tube. Proc R Soc (London) 219:186–203CrossRefGoogle Scholar
  7. 7.
    Henley TH, Wilburn RT, Crouch AM, Jorgenson JW (2005) Flow counterbalanced capillary electrophoresis using packed capillary columns: resolution of enantiomers and isotopomers. Anal Chem 77:7024–7031CrossRefGoogle Scholar
  8. 8.
    Yanagisawa N, Dutta D (2010) Pressure generation at the junction of two microchannels with different depths. Electrophoresis 31:2080–2088CrossRefGoogle Scholar
  9. 9.
    Fu JL, Fang Q, Zhang T, Jin XH, Fang ZL (2006) Laser-induced fluorescence detection system for microfluidic chips based on an orthogonal optical arrangement. Anal Chem 78:3827–3834CrossRefGoogle Scholar

Copyright information

© Springer Science+Business Media, LLC, part of Springer Nature 2019

Authors and Affiliations

  1. 1.Department of Applied ChemistrySun Yat-Sun UniversityGuangzhouPeople’s Republic of China
  2. 2.Department of ChemistryUniversity of WyomingLaramieUSA

Personalised recommendations