Abstract
Analytical cytometry has significant potential beyond cellular analysis. The inherent capability of flow cytometers to efficiently discriminate between uniformly sized particles based on their intrinsic properties provides the foundation for multiplex bead assays. The technology can be exploited in designing immunoassays, Western blot-like antibody assays, and nucleic acid hybridization assays. This chapter focuses on immunoassay applications. The multiplex bead assays have recently evolved as a new and increasingly popular area for flow cytometry, becoming a good alternative to enzyme-linked immunosorbent assay for efficient evaluation of panels of analytes. This chapter provides detailed information about two bead platforms, the BD™ Cytometric Bead Array kits and the BD Cytometric Bead Array Flex Set Assays.
Access this chapter
Tax calculation will be finalised at checkout
Purchases are for personal use only
References
Carson, R. T. and Vignali, D. A. (1999) Simultaneous quantitation of fifteen cytokines using a multiplexed flow cytometric assay. J. Immunol. Meths. 227, 41–45.
Morgan, E., Varro, R., Sepulveda, H., et al. (2004) Cytometric bead array: a multiplexed assay platform with applications in various areas of biology. Clin. Immunol. 110, 252–266.
Stall, A., Sun, Q., Varro, R., et al. (1998) A single tube flow cytometric multibead assay for isotyping mouse monoclonal antibodies. Abstract 1877, Experimental Biology Meeting.
Lund-Johansen, F., Davis, K., Bishop, J. E., and Malefyt, R. de W. (2000) Flow cytometric analysis of immunoprecipitates: high-throughput analysis of protein phosphorylation and protein-protein interactions. Cytometry 39, 250–259.
Fulwyler, M. J., McHugh, T. M., Schwadron, R., et al. (1988) Immunoreactive bead (IRB) assay for the quantitative and simultaneous flow cytometric detection of multiple soluble analytes. Cytometry 2, 19.
McHugh, T. M. (1994) How microsphere immunoassay for the quantitative and simultaneous detection of multiple soluble analytes. Methods Cell Biol. 42, 575–595.
Camilla, C., Defoort, J. R, Delaage, M., et al. (1998) A new flow cytometry-based multi-assay system. 1. Application to cytokine immunoassays. Cytometry 8, 132.
Chen, R., Lowe, L., Wilson, J. D., et al. (1999) Simultaneous quantification of six human cytokines in a single sample using microparticle-based flow cytometric technology. Clin. Chem. 9, 1693–1694.
Fulton, R. J., McDade, R. L., Smith, P. L., Kienker, L. J., and Kettman, J. R. (1997) Advanced multiplexed analysis with the FlowMetrix system. Clin. Chem. 43, 1749–1756.
McHugh, T. M., Viele, M. K., Chase, E. S., and Recktenwald, D. J. (1997) The sensitive detection and quantitation of antibody to HCV using a microsphere-based immunoassay and flow cytometry. Cytometry 29, 106–112.
Faucher, S., Martel, A., Sherring, A., et al. (2004) Protein bead array for the detection of HIV-1 antibodies from fresh plasma and dried-blood-spot specimens. Clin. Chem. 50, 1250–1253.
Khan, I. H., Kendall, L. V., Ziman, M., et al. (2005) Simultaneous serodetection of 10 highly prevalent mouse infectious pathogens in a single reaction by multiplex analysis. Clin. Diagn. Lab. Immunol. 12, 513–519.
Cook, E. B., Stahl, J. L., Lowe, L., et al. (2001) Simultaneous measurement of six cytokines in a single sample of human tears using microparticle-based flow cytometry: allergics vs. non-allergics. J. Immunol. Meths. 254, 109–118.
Sonoda, S., Uchino, E., Nakao, K., and Sakamoto, T. (2006) Inflammatory cytokine of basal and reflex tears analysed by multicytokine assay. British J. Ophthalmology 90, 120–122.
Tárnok, A., Hambsch, J., Chen, R., and Varro, R. (2003) Cytometric bead array to measure six cytokines in twenty-five microliters of serum Clin. Chem. 49, 1000–1002.
Hodge, G., Hodge, S., Haslam, R., et al. (2004) Rapid simultaneous measurement of multiple cytokines using 100 microliter sample volumes—association with neonatal sepsis. Clin. Exp. Immunol. 137, 402–407.
Jatta, K., Wågsäter, D., Norgren, L., Stenberg, B., and Sirsjö, A. (2005) Lipopoly-saccharide-induced cytokine and chemokine expression in human carotid lesions. J. Vasc. Res. 42, 266–271.
Peiris, J. S., Yu, W. C., Leung, C. W., et al. (2004) Re-emergence of fatal human influenza A subtype H5N1 disease. Lancet 363, 617–619.
Rodriguez-Caballero, A., Garcia-Montero, A. C., Bueno, C., et al. (2004) A new simple whole blood flow cytometry based method for simultaneous identification of activated cells and quantitative evaluation of cytokines released during activation. Laboratory Investigation 84, 1387–1398.
Chen, L., Apgar, I, Huynh, L., et al. (2005) ZAP-70 directly enhances IgM signaling in chronic lymphocytic leukemia. Blood 105, 2036–2041.
Author information
Authors and Affiliations
Editor information
Editors and Affiliations
Rights and permissions
Copyright information
© 2007 Humana Press Inc., Totowa, NJ
About this protocol
Cite this protocol
Varro, R., Chen, R., Sepulveda, H., Apgar, J. (2007). Bead-Based Multianalyte Flow Immunoassays. In: Albitar, M. (eds) Monoclonal Antibodies. Methods in Molecular Biology, vol 378. Humana Press. https://doi.org/10.1007/978-1-59745-323-3_9
Download citation
DOI: https://doi.org/10.1007/978-1-59745-323-3_9
Publisher Name: Humana Press
Print ISBN: 978-1-58829-567-5
Online ISBN: 978-1-59745-323-3
eBook Packages: Springer Protocols