Rolf Maximilian Sievert (1896–1966): father of radiation protection Masaru SekiyaMichio Yamasaki Editorial 29 July 2015 Pages: 1 - 5
Detection and measurement of rheumatoid bone and joint lesions of fingers by tomosynthesis: a phantom study for reconstruction filter setting optimization Yohei OnoTamotsu KamishimaKaori Tsutsumi OriginalPaper 20 June 2015 Pages: 6 - 14
Effect of the saturation pulse duration on chemical exchange saturation transfer in amide proton transfer MR imaging: a phantom study Tatsuhiro WadaOsamu TogaoYasuhiko Nakamura OriginalPaper 23 June 2015 Pages: 15 - 21
Analyzing the performance of the planning system by use of AAPM TG 119 test cases L. NithyaN. Arunai Nambi RajManish Bhushan Pandey OriginalPaper 04 July 2015 Pages: 22 - 29
Automatic ROI construction for analyzing time–signal intensity curve in dynamic contrast-enhanced MR imaging of the breast Koya FujimotoYasuyuki UedaKatsuhiko Ueda OriginalPaper 04 July 2015 Pages: 30 - 36
Monte Carlo modeling of a conventional X-ray computed tomography scanner for gel dosimetry purposes Homa HayatiAsghar MesbahiMahmood Nazarpoor OriginalPaper 25 July 2015 Pages: 37 - 43
A computer simulation method for low-dose CT images by use of real high-dose images: a phantom study Tomomi TakenagaShigehiko KatsuragawaJunji Shiraishi OriginalPaper 20 August 2015 Pages: 44 - 52
Rotational output and beam quality evaluations for helical tomotherapy with use of a third-party quality assurance tool Hidetoshi ShimizuKoji SasakiTakeshi Kodaira OriginalPaper 23 August 2015 Pages: 53 - 59
Evaluation of X-ray doses and their corresponding biological effects on experimental animals in cone-beam micro-CT scans (R-mCT2) Nobuyuki MiyaharaToshiaki KokuboYoshinori Arai OriginalPaper Open access 06 October 2015 Pages: 60 - 68
Z-score-based semi-quantitative analysis of the volume of the temporal horn of the lateral ventricle on brain CT images Noriyuki TakahashiToshibumi KinoshitaDu-Yih Tsai OriginalPaper 24 September 2015 Pages: 69 - 76
Accuracy of dose calculation algorithms for virtual heterogeneous phantoms and intensity-modulated radiation therapy in the head and neck Ryota OnizukaFujio ArakiKazunari Hioki OriginalPaper 22 October 2015 Pages: 77 - 87
Development of a single-photon-counting camera with use of a triple-stacked micro-channel plate Naruomi YasudaHitoshi SuzukiTetsuro Katafuchi OriginalPaper 20 October 2015 Pages: 88 - 94
Evaluation of AutoCAL for electronic portal imaging device-based multi-leaf collimator quality assurance Tarafder J. Shameem OriginalPaper 27 October 2015 Pages: 95 - 98
Energy dependence measurement of small-type optically stimulated luminescence (OSL) dosimeter by means of characteristic X-rays induced with general diagnostic X-ray equipment Kazuki TakegamiHiroaki HayashiIkuo Kobayashi OriginalPaper 20 November 2015 Pages: 99 - 108
Effect of X-ray beam quality on determination of exposure index Shogo YasumatsuNobukazu TanakaJunji Morishita OriginalPaper 30 November 2015 Pages: 109 - 115
Evaluation of the effects of subject thickness on the exposure index in digital radiography Takeshi TakakiKazuki TakedaMasatoshi Sakamoto OriginalPaper 27 November 2015 Pages: 116 - 120
Dynamic positioning accuracy of a novel multileaf collimator for volumetric modulated arc therapy Yuji NakaguchiTakeshi OnoYudai Kai OriginalPaper 26 November 2015 Pages: 121 - 126
Effects of point spread function-based image reconstruction on neuroreceptor binding in positron emission tomography study with [11C]FLB 457 Thonnapong ThongpraparnYoko IkomaHiroshi Ito OriginalPaper 16 December 2015 Pages: 127 - 137