Abstract
Background
Subclavian artery injury during internal jugular vein catheterization is a rare yet potentially life-threatening complication leading to hemothorax and exsanguination. The percutaneous endovascular approach offers a less invasive and effective alternative to the high-risk surgical repair in emergent situations.
Case presentation
We present a case of a 6-year-old child suffering from hemolytic uremic syndrome requiring urgent hemodialysis, for which IJV (internal jugular vein) cannulation was attempted. This procedure led to iatrogenic subclavian arterial perforation causing massive hemothorax with hemodynamic compromise. CT angiogram showed a through and through perforation in the first part of right subclavian artery between common carotid and vertebral artery. A definitive assessment of the extent of ongoing leak was made through an invasive angiogram in the catheterization laboratory. The perforation was successfully closed percutaneously with a covered stent without compromising any branch vessels.
Conclusion
Arterial injury although rare is a potentially life-threatening complication of IJV cannulation which warrants immediate attention and corrective measures. Ultrasound guidance can reduce the risk of such life-threatening complications. Percutaneous management offers a less invasive, less time consuming, and effective alternative in critically ill patients in emergency situations.
Similar content being viewed by others
Background
Central line placement has become the standard of care in critical care settings. Complications during internal jugular vein (IJV) cannulation occur in 15% of patients [1]. Arterial injury can cause significant hemodynamic compromise, when not recognized in time. Open surgical repair requires extensive dissection in a critically ill patient, precluding its universal use. Therefore, endovascular intervention offers a less invasive and effective alternative to open surgical repair in emergencies.
Case presentation
A 6-year-old child, weighing 15 kg, was diagnosed to have hemolytic uremic syndrome (HUS) and was advised for hemodialysis. Right IJV was selected for dialysis catheter insertion. After insertion, no blood was aspirable from the catheter raising doubt about the position of catheter tip. Therefore, the catheter was removed after which there was a sudden hemodynamic deterioration. Massive hemothorax was suspected which was confirmed by chest radiograph. After resuscitation with multiple transfusions (6 units of packed red cells) and intercoastal drain insertion, CT was performed. It showed leak from a through and through rent in the first part of right subclavian artery (SCA) between common carotid artery (CCA) and vertebral artery (VA). The emergency multidisciplinary team consisting of nephrologists, intensivists, cardio-vascular surgeons, radiologists, and cardiologists felt that the perforation needs to be addressed along with renal dysfunction, low platelet count (50 × 109/l), and disseminated intravascular coagulation. It was felt that the percutaneous approach is the most appropriate measure considering the less invasive nature of the procedure, short and long term implications, age, and poor general condition of the child.
Procedure details
Arterial access (left femoral artery, as the right femoral vein was used for hemodialysis catheter, for ease of access left side was used) was gained using 6 Fr sheath. Fluoroscopy of the thorax showed mediastinal shift to the left (Fig. 1a) altering the anatomy of the aortic arch and neck vessels. Selective injection of the right brachiocephalic artery (6 Fr Judkins right catheter, Judkins right was used for selective injections) showed contrast leak from the first part of the right subclavian artery between CCA and VA (Fig. 1b). Although the leak appreciated was minimal, questioning the significance of bleed and intervention in such a small child, we could not rule out the “tamponade effect” by the large hemothorax which could be misleading. Hence, we replaced the existing intercostal draining tube (ICD) with a wide bore one. As the child had hypotension following ICD revision, resuscitation measures were carried out simultaneously with packed cell transfusion. A repeat injection showed a significant contrast leak from the first part of right subclavian artery (Fig. 1c). It was decided to attempt a “balloon tamponade” to tackle this peroration with the hope to avoid stenting in a small child. A 0.014″ BMW wire (Abbott Vascular TM) was parked in the right axillary artery, and sustained inflations were given serially (3.0, 3.5, and 4.0 mm balloons) (Fig. 2a, b). As repeat injection during balloon inflation showed persistent contrast leak (Fig. 2c), it was decided to proceed with a covered stent. The most appropriate size of covered stent available at that time was a 4 × 16 mm GRAFTMASTER (ABBOTT VASCULAR TM) which was deployed at 22 atm (Fig. 3a). We had to face a few more challenges than just hemodynamic support in this case as described below. While the deflated stent balloon was being withdrawn, the stent migrated proximally getting stationed at the origin of right CCA (Fig. 4a) raising concern of cerebral flow compromise. An attempt was made to push the migrated stent distally beyond the ostium of CCA with the help of a partially inflated balloon (Fig. 4b) which sorted out the issue. The partially inflated 5.0 × 14 mm non-compliant (NC) balloon was used to position the stent in between CCA and VA (Fig. 4c). Later, it was post dilated with 5.0 mm and 5.5 mm NC balloon with good apposition (Fig. 4d). Repeat injection showed no contrast leak. The hemodynamic status improved with no requirement of blood products after the procedure. No neurological complications were seen. He was extubated 2 days later. His renal dysfunction and supportive management were continued under expert care. Single antiplatelet was advised after the platelet count improved to more than 100 × 109/L.
Discussion
Central venous catheter provides multiple venous access in critically ill patients for hemodynamic monitoring, fluid resuscitation, administration of inotropes, nutritional support, and hemodialysis [2]. The complication rate is about 15% including mechanical (arterial puncture, pneumothorax, and hematoma), infectious, and thrombotic complications [1]. Ultrasound guidance reduces the risk of mechanical complication, procedure failure, and shortens the time required for insertion [2]. Arterial injury occurs in around 0.5 to 3.7% of cases in the form of hematoma, hemothorax, pseudoaneurysm, and arteriovenous fistula. The most common arterial injury associated with IJV cannulation is carotid artery puncture. Subclavian artery injury is a rare complication. The typical clinical presentation is a triad of IJV cannulation, hypotension, and X-ray evidence of hemothorax [3, 4]. Management guidelines in cases of arterial injury are not very clear. Open surgical repair involves extensive surgical dissection in critically ill patients. Percutaneous management offers a less invasive, less time consuming alternative in critically ill patients in emergencies. Literature search showed only a few case reports of percutaneous management of arterial injury following IJV cannulation. In one of the cases, the misplaced catheter intended to be put in IJV was detected on chest X-ray. When the catheter was removed after 2 days, there was a hemodynamic compromise that was managed with stent graft [4]. In another case, a vascular plug was used to close the arterial injury that occurred during subclavian venous puncture [5]. Comparison of percutaneous approach with open surgical approach found to be non-inferior in terms of success and better in safety. In a retrospective case series where endovascular approach using stent graft was compared with surgical approach for subclavian artery injuries (three of them caused by subclavian artery catheterization attempts), it was shown that blood loss (70 ± 12.2 mL vs 220 ± 56.1 mL; P < 0.01) and procedural time (132 ± 15 min vs 193 ± 15 min; P = 0.04) was lesser in endovascular group [6]. There was no difference in patency rates between the two groups [6]. Endovascular treatment obviates the need for surgical dissection preventing injury to the adjacent structures like vagus nerve, recurrent laryngeal nerve, phrenic nerve, and innominate vein [6]. Careful selection of the patient is necessary as lesions that are focal and are at a good distance from the vertebral artery are amenable for endovascular therapy. In our case, we had a sick child with HUS, thrombocytopenia, and acute renal failure requiring renal replacement therapy had hemothorax following IJV catheter placement leading to hemodynamic instability which was managed with multiple blood products transfusions. In such cases, open repair is difficult due to critically ill status and severe thrombocytopenia. We went ahead with the endovascular approach as it is less invasive and less time consuming. We encountered the problems of undersized stent and its poor apposition to the vessel wall leading to stent migration which was successfully managed. Using stent in a growing child has its implications like in-stent restenosis; vessel growth to stent size remains a challenge in the future, though development of collaterals would ensure adequate limb growth and functioning.
Conclusion
Arterial injury although rare is a potentially life-threatening complication of IJV cannulation which warrants immediate attention and correction. Ultrasound guidance during central venous catheter placement helps in avoiding mechanical complications. The endovascular technique offers a less invasive approach with less morbidity in critically ill and emergencies.
Availability of data and materials
The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.
Abbreviations
- BMW:
-
Balance middle weight
- CCA:
-
Common carotid artery
- CT:
-
Computed tomography
- ICD:
-
Intercostal drainage tube
- IJV:
-
Internal jugular vein
- NC:
-
Non-compliant
- VA:
-
Vertebral artery
References
Merrer J et al (2001) Complications of femoral and subclavian venous catheterization in critically ill patients: a randomized controlled trial. JAMA. 286(6):700–707
McGee DC, Gould MK (2003) Preventing complications of central venous catheterization. N Engl J Med. 348(12):1123–1133
Mansfield PF, Hohn DC, Fornage BD, Gregurich MA, Ota DM (1994) Complications and failures of subclavian-vein catheterization. N Engl J Med. 331(26):1735–1738
Fyntanidou B, Vasiliadou G, Papachristodoulou A, Pantazopoulou A, Megalopoulos A, Trellopoulos G (2008) Endovascular repair of inadvertent subclavian artery injury during attempted internal jugular vein catheterization: a case report. Int J Endovasc Med 1:2
Ananthakrishnan G, White RD, Bhat R, Chakraverty S (2012) Inadvertent subclavian artery cannulation: endovascular repair using a collagen closure device—report of two cases and review of the literature. Case Rep Vasc Med 2012(150343):4
Xenos ES, Freeman M, Stevens S, Cassada D, Pacanowski J, Goldman M (2003) Covered stents for injuries of subclavian and axillary arteries. J Vasc Surg. 38(3):45
Acknowledgements
None.
Funding
No funding has been received for the current study.
Author information
Authors and Affiliations
Contributions
KP was involved in the collection of the data and drafting and revising the manuscript for important intellectual content. KS, AAG, and BK were involved in the collection of the data and preparing the first draft. SN was involved in the conception of the study, revising the manuscript for important intellectual content, and approving the manuscript. All the authors have read and approved the manuscript.
Corresponding author
Ethics declarations
Ethics approval and consent to participate
Not applicable
Consent for publication
Written and informed consent has been obtained from the next of kin (father) to publish the case report. The consent copy is available with the authors and ready to be submitted if required.
Competing interests
The authors declare that they have no competing interests.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Supplementary information
Additional file 1: Video 1.
Selective angiogram of right subclavian artery showing contrast leak from the first part of subclavian artery between right common carotid artery and vertebral artery.
Additional file 2: Video 2.
Fluoroscopy showing covered stent being deployed at the site of leak.
Additional file 3: Video 3.
Final angiogram showing sealed perforation with no compromise of branch vessels.
Rights and permissions
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.
About this article
Cite this article
Naganur, S., Santosh, K., Sihag, B.K. et al. Bailout subclavian artery stenting in a sick child with iatrogenic subclavian artery perforation: a case report. Egypt Heart J 72, 19 (2020). https://doi.org/10.1186/s43044-020-00056-2
Received:
Accepted:
Published:
DOI: https://doi.org/10.1186/s43044-020-00056-2