Background

Chronic kidney disease (CKD) is a major contemporary health problem. The number of patients with CKD continues to increase globally, with a current estimate of 2.6 million CKD patients worldwide [1]. Patients with CKD are at a higher risk of various complications, such as high blood pressure and heart disease, in addition to the frequent occurrence of chronic inflammation, renal anemia, and sarcopenia [2]. While exercise is reported to improve chronic inflammation [3], recent reports have noted that electrical stimulation (ES) is effective not only in patients with moderate to severe heart failure [4], but also in hemodialysis (HD) patients [5]. ES and voluntary muscular contractions during cycle ergometer training are different ways of activating muscle fibers that influence a number of acute changes in the neuromuscular system [5]. ES activates type I muscle fibers, while anaerobic exercise activates type II muscle fibers. In addition, conventional training using cycle ergometers is a whole-body exercise, whereas ES is a static and localized body exercise. Therefore, ES might be effective for elderly patients undergoing HD who have disease complications.

Based on this perspective, achieving a higher training benefit in HD patients would be of great importance. However, effects of ES on physical function and indicators of biochemical changes in maintenance HD patients are unknown. Therefore, this study aimed to evaluate and compare the effects of ES on muscle strength, dialysis efficiency, and serum inflammatory markers, including cytokine factors in elderly patients undergoing maintenance HD.

Methods

Study design and participants

This study was a prospective, double-center, open-label, randomized controlled trial. Subjects included stable patients on maintenance HD who underwent outpatient HD treatments three times a week between February 2014 and March 2016 at two dialysis centers in Japan (Fig. 1). This study was approved by the Tohoku University Hospital Review Board (no. 2011-120-1) and the Tsukuba University of Technology Review Board (no. 05/02/2015). The study was also retrospectively registered on the UMIN Clinical Trials Registry (UMIN-CTR R 000032202).

Fig. 1
figure 1

Flow chart showing enrollment and grouping assignment of patients. Of 320 Japanese hemodialysis (HD) outpatients who were screened for eligibility, 50 consecutive patients who met the inclusion criteria were approached for study participation. Ultimately, 30 patients (23 men, 7 women) were included in this study. EX exercise, ES electrical stimulation, SED control

At the initiation of the present study, we identified 320 patients who were undergoing maintenance HD at both dialysis centers. The inclusion criteria were as follows: (1) patients who underwent dialysis treatment for at least 3 months and (2) age older than 65 years. The exclusion criteria were (1) acute coronary syndrome, particularly unstable angina and acute myocardial infarction; (2) systolic blood pressure ≥ 180 mmHg or diastolic blood pressure ≥ 110 mmHg; and (3) patients who were determined as inappropriate for the study by the attending physician. The first 50 eligible patients were consecutively approached to participate in this study; however, 7 patients were further excluded because a physician determined that they were inappropriate for this study. As a result, 43 patients were initially included. Of these 43 patients, 13 patients withdrew from participation due to poor physical conditions. Finally, 30 subjects (23 men and 7 women) were randomly assigned to one of three groups (n = 10 per group).

Randomization

Eligible patients were randomized to one of three groups described below. After the first evaluation, randomization was generated using online software (www.random.org). The three groups included a group that exercised on a variable load ergometer (EX group), a group that underwent low-frequency ES of the lower limbs (ES group), and a group that underwent standard HD treatment without exercise (SED). The median age of the subjects was 71.5 ± 1.6 years, and their mean time on dialysis was 10.7 ± 1.9 years. All subjects were minimally active and exercised less than once per week before the intervention. After patient selection, the sequence of numbers was generated by researchers who were blinded to the study. Prior to the start of the intervention program, the sequence of numbers was only disclosed to the expert nurse or the physical therapist who was responsible for applying the respective treatment (ES, EX, or SED) to ensure concealment of the allocation sequence and to keep patients blinded to the type of intervention.

Using the G*power statistics software (version 3.1; Heinrich-Heine-University, Düsseldorf, Germany), sample size calculation was performed based on a 5% alpha error and 80% power for a magnitude of effect of 1.181. To calculate the sample size, a mean between group difference of 3.9 ± 0.2 kgf for muscle power of the quadriceps femoris (MPQ) was used, as reported by Banerjee et al. [6]. According to the calculation performed, a sample of 10 subjects was required in each group.

Data collection

Physical parameters included baseline demographic characteristics, hand grip strength, leg muscle force, and weight bearing index (WBI) conversion. Biochemical parameters included dialysis efficiency, serum blood urea nitrogen (BUN), phosphorus, high-density lipoprotein cholesterol (HDL-C), low-density lipoprotein cholesterol/HDL-C (LDL-C/HDL-C), renal anemia indicators (ferritin [Fer] and transferrin saturation [TSAT]), nutritional status indicator (albumin), and inflammation markers (C-reactive protein [CRP], interleukin-6 [IL-6], and tumor necrosis factor-alpha [TNF-α]). At baseline and 12 weeks after the intervention, these parameters were collected before the HD session and under the same conditions; all procedures were carried out using the same protocol at both dialysis centers.

Hand grip strength

At baseline and 12 weeks after the intervention, hand grip strength was measured before the HD session and under the same conditions by the expert nurse and physical therapists who were not informed about the study details. Hand grip strength was measured using the Smedley Hand Dynamometer (OG Giken, Okayama, Japan). Measurements were completed using the arm opposite to the arm in which vascular access was installed before the HD session. All measurements were performed with the patient in a seated position, the shoulder in adduction and in a neutral position, the elbow in 90° flexion, and the forearm in a neutral position. The test was conducted three times with the subject exerting maximum force to ensure reliability, and the mean value of these three trials was recorded [7].

Maximum isometric knee extensor muscle power of the quadriceps femoris (MPQ) and WBI conversion

At baseline and 12 weeks after the intervention, physical conditions were measured before the HD session and under the same conditions. Maximum isometric knee extensor MPQ was measured using a handheld dynamometer (IsoforceGT-300; OG Wellness Technologies Co., Ltd., Okayama, Japan) by the expert nurse and physical therapists who were not informed about the study details. MPQ was measured from an initial seated position squarely with the hip and the knee joints at a 90° angle. The test was measured twice on each leg, and the maximum value was used. The WBI was calculated as WBI = MPQ/body weight [8].

Laboratory examination

At baseline and 12 weeks after the intervention, blood samples were collected after at least 12 h of fasting, and before the HD session, from an antecubital vein via venipuncture. Dialysis efficiency (represented using Kt/V) was calculated from body weight and BUN levels before and after dialysis using the Daugirdas formula [9] as follows. Single-pool Kt/V was calculated monthly using urea kinetic modeling equations derived from the following equation: (post: pre-dialysis plasma BUN ratio to estimate k. T/v and npcr: mathematical modeling) (second-generation logarithmic estimates of single-pool variable volume kt/v: an analysis of error). Kt/V = − ln(R − 0.008 × t) + [(4–3.5 × R) × UF/W], where R is the ratio of post-dialysis to pre-dialysis serum BUN concentration, t is the duration of hemodialysis in hours, UF is the amount of ultrafiltration (in l) during the hemodialysis session, and W is the post-dialysis weight (in kg) [10]. Serum BUN, phosphorus, HDL-C, LDL-C/HDL-C, Fer, TSAT, albumin, CRP, IL-6, and TNF-α were analyzed at SRL Co., Ltd., Tokyo, Japan.

Conventional aerobic training (exercise with variable load ergometers)

Subjects exercised for 1 h or less during the first half of the HD session twice a week for 12 consecutive weeks using a cycle ergometer (TE2-70; Showa Denki Co., Ltd., Osaka, Japan). Exercise duration was determined based on an exercise intensity relative to levels 11–13 on the Borg Rating of Perceived Exertion (RPE) scale. RPE was recorded, and time limits were set depending on the subject’s physical conditions. The exercise was performed at an intensity where the subject’s heart rate did not exceed 30 bpm above resting heart rate.

Low-frequency ES

A low-frequency ES device (Espurge, Ito Co., Ltd., Tokyo, Japan) was used. Electrodes were attached to the bilateral quadriceps femoris and triceps surae muscles. ES was applied at 10 Hz below the subject’s pain threshold and was turned on and off in 20-s cycles. Subjects underwent ES for 1 h or less during the first half of the HD session twice a week for 12 consecutive weeks [4, 5]. ES was applied such that the subject’s heart rate did not exceed 30 bpm above resting heart rate.

Statistical analysis

Estimates of arithmetic mean and standard error were used as standard summary statistics while obtaining primary data. Prior to parametric data processing, we verified sample distribution normality (Shapiro-Wilk’s test) and variance homogeneity. Two-way repeated measures analysis of variance was performed as the principal method to evaluate the outcomes of the experimental groups (ES, EX, and SED as independent, effect components) and sampling at different time points (as a dependent, pairwise component). A post hoc test was completed for variables with a significant difference depending on their parameters (Tukey-Kramer or Scheffé procedures). Greenhouse-Geisser correction was applied as Mauchly’s test of sphericity was not met. SPSS 22.0 for Windows (IBM Corp., Armonk, NY, USA) was used for all analyses, and a value of p < 0.05 was considered statistically significant.

Results

Table 1 displays the subjects’ baseline characteristics. There were no significant differences among the three groups at baseline in terms of age, male/female ratio, HD duration, body mass index, and diabetic nephropathy ratio (Table 1).

Table 1 Patient baseline characteristics separated by experimental groups

Physical parameters at baseline and 12 weeks after the intervention are presented in Table 2. With the exception of hand grip strength, there were no significant differences among the groups at baseline. After the 12-week intervention, the EX group showed a significant improvement in hand grip strength (from 19.7 ± 0.7 to 21.9 ± 0.8 kg; p = 0.02). In contrast, MPQ (from 13.1 ± 0.1 to 15.7 ± 1.6 kgf; p = 0.01) and WBI (from 0.2 ± 0.1 to 0.3 ± 0.1 kgf/kg; p = 0.04) significantly increased in the ES group only.

Table 2 Changes in physical parameters in the ES (n = 10), EX (n = 10), and SED (n = 10) groups

Biochemical parameters at baseline and 12 weeks after the intervention are presented in Table 3. Dialysis efficiency (evaluated via Kt/V) significantly improved in both the ES (from 1.3 ± 0.0 to 1.5 ± 0.0; p = 0.01) and EX groups (from 1.3 ± 0.0 to 1.5 ± 0.0; p = 0.02), but not in the SED group. Phosphorus level significantly decreased (from 6.0 ± 0.0 to 4.7 ± 0.1 mg/dl; p = 0.04) in the ES group. HDL-C level significantly decreased in the both the EX and ES groups; however, LDL-C/HDL-C level did not significantly change in these groups. Regarding immunological factors, in the EX group, serum CRP level significantly decreased (from 0.7 ± 0.1 to 0.4 ± 0.1 mg/dl; p = 0.04), while serum TNF-α level significantly increased (from 6.5 ± 1.0 to 7.0 ± 0.3 pg/ml; p = 0.03). Similarly, serum TNF-α level increased (from 6.2 ± 0.5 to 9.3 ± 0.8 pg/ml; p = 0.02) in the SED group, with no change detected in serum CRP after the 12-week intervention. Conversely, although serum CRP did not change, serum TNF-α level significantly decreased (from 6.7 ± 0.3 to 4.5 ± 0.1 pg/ml; p = 0.04) in the ES group. There were no significant changes in other parameters and in group differences.

Table 3 Changes in biochemical parameters in the ES (n = 10), EX (n = 10), and SED (n = 10) groups

Discussion

To our knowledge, the present study was the first to investigate the effect of ES of skeletal muscles and aerobic training on physical function and biochemical parameters in elderly patients with CKD. Our major finding was that MPQ, WBI, Kt/V, serum phosphorus, and TNF-α level significantly changed from baseline to 12 weeks after the intervention in the ES group; however, there were no significant differences among the three groups at baseline for any parameters, except for hand grip strength. Additionally, in the EX and ES groups, HDL-C level significantly decreased from baseline to 12 weeks after the intervention, but no change was observed for LDL-C/HDL-C level. Therefore, these results support our hypothesis that training twice per week for 12 weeks during HD sessions in elderly patients with ESRD improves physical function and biochemical markers without any adverse effects.

However, the indicators of muscle power for the lower limbs (MPQ and WBI) significantly changed in the ES group only. The major difference between exercising on a cycle ergometer and lower leg ES is that the former is an endurance exercise of the lower limbs [11], whereas the latter induces muscle contraction without local articular exercise [4]. Both cycle exercise and lower limb ES involve muscle contraction. During cycle exercises, the appropriate number of motor units is recruited according to the exercise intensity, whereas ES may activate all motor units simultaneously [12]. That is, the major difference may be the possibility of ES to recruit the same number of motor units as high intensity exercises even at a low intensity. In the present study, the EX and ES groups conducted aerobic exercises at the same intensity (RPE 11–13). A preliminary experiment of expired gas measurement in two healthy individuals who underwent cycle ergometer exercise and lower leg ES revealed that the exercise was at or below an anaerobic threshold level for both tests. Therefore, the following reasons explain the lack of changes in muscle power in the EX group. Meanwhile, hand grip strength significantly improved in both the ES and EX groups. Several studies reported that improvement of muscle power in the lower limbs correlated with that in the upper limbs [13,14,15], which was similar with the results of the current study.

First, the exercise completed in this study was an endurance training of whole-body exercise [16], which may have improved endurance but was likely not enough to improve power in the EX group. The present study showed that in the ES group, MPQ increased while HDL-C significantly decreased with no changes in the other parameters. Although there is evidence that physical activity is beneficial in the general population, more work is required to determine the overall effects of exercise on physical activity in elderly patients with ESRD. Second, the exercise was performed at an RPE of 11–13 in the EX group, which may not have been high enough to reinforce muscle strength [17]. However, changes were observed in the ES and SED groups, as well as significant changes in inflammation markers CRP and TNF-α after the 12-week intervention. In addition, Kt/V significantly increased after the intervention in the ES and EX groups, whereas serum phosphorus and serum TNF-α levels significantly decreased in the ES group only. According to previous studies [4, 5, 18], ES of the legs was equally effective as exercise, but its effects were dependent on localized increases in muscular strength [19]. The present results also demonstrate that WBI increased because the leg muscles were strengthened. The reason for this finding is that ES only affects local function. Several investigators have examined the effects of repeated ES on muscle strength and reported increased strength of the skeletal muscles, improved muscle contraction in patients after knee surgery, and decreased atrophy. These findings indicate that ES might prevent and ameliorate disuse atrophy due to immobilization without requiring excessive effort.

However, there were no changes in anemia- and cholesterol-related factors from baseline to the end of the intervention. The exercise intensity and limited intervention duration (12 weeks) may not have been sufficient to induce changes in these factors. Problems specific to ES include the potential for local skin burns or irritation, electrode sensitivity, autonomic dysreflexia, surface burns, and skin inflammation. Previous studies reported that exercise training could be performed during HD sessions without any adverse effects. Likewise, our subjects did not experience any adverse effects, such as a sudden drop in blood pressure or cardiovascular disease.

On the other hand, previous studies reported that exercise improves inflammation; however, in the current study, serum CRP level significantly decreased after the intervention in the EX group and serum TNF-α level significantly increased. This elucidates that CRP is an indicator of systemic inflammation, whereas TNF-α can fluctuate with exercise and cause changes in psychological or physiological conditions, in addition to inflammation [20]. Therefore, it is reasonable that the CRP and TNF-α levels diverged in the present study.

In addition, serum phosphorus level decreased in the ES group only. We believe that this was an effect of muscle contraction on phosphorus metabolism, as explained in previous research [21]. The onset of poor physical condition was associated with bone metabolism, and the emergence of sarcopenia was accompanied by increased levels of inflammatory factors TNF-α and IL-6 [22].

Furthermore, subjects in both the EX and ES groups were able to safely undergo the intervention without shunt trouble, sudden drop in blood pressure, or the need for fluid replacement. Previous studies also reported that intra-dialytic exercise prolongs vital prognosis without adverse events [23]. Likewise, ES has also been safely conducted in previous studies without causing skin problems or new-onset heart failure [4, 24]. Therefore, ES of the lower limbs has beneficial effects on muscle power, systemic inflammation, and the prevention of falls in elderly patients undergoing HD.

Some limitations of our study should be considered. First, the study involved a relatively small sample size, and the study period was too short to determine long-term effects of exercise. Future examinations on efficacy should include a larger sample size and include a selection of resistance training adapted for Asian patients of advanced age.

Conclusion

ES of the legs and cycle exercise can be safely performed during dialysis. A comparison of ES and EX suggested that ES was more effective in improving muscle power of the lower limbs and TNF-α; therefore, ES might be effective for elderly patients with disease complications requiring HD.