Background

Sepsis is a heterogeneous syndrome characterizing the body’s response to serious infection. Although a standard clinical definition has been proposed [1], its clinical course is highly variable with some patients experiencing a relatively benign illness and others progressing to shock and multi-organ failure [2]. Endothelial dysfunction is a key hallmark of this progression as its resultant vascular permeability leads to cardiovascular compromise as well as organ edema and failure. While several critical functions of the endothelium have been identified in sepsis [36], the biological underpinnings governing the development of endothelial dysfunction in this syndrome are incompletely understood and represent an important area of study in order to characterize the pathogenesis of septic shock.

MicroRNAs (miRNAs) are small (19–25 nucleotides) noncoding segments of RNA that regulate gene expression by binding to target mRNA and inhibiting their translation [79]. Cell-to-cell delivery of miRNAs through vesicular structures such as exosomes has been described in a variety of cell types including endothelial cells and has been shown to impact cellular function [1013]. Our previous work demonstrated that treatment of murine sepsis with human endothelial progenitor cells (EPCs) improves survival while attenuating vascular leak and its resultant organ failure [14]. Endothelial progenitor cells release exosomes that contain miRNAs known to promote the homeostasis and barrier integrity of endothelial cells [1417] and may be a mechanism by which EPCs modulate sepsis-induced vascular leak. Thus, a deeper understanding of the role that endothelial-relevant miRNAs may play in the pathogenesis of endothelial dysfunction and shock is warranted.

In the current study, we have demonstrated that 13 miRNAs that have known associations with sepsis [14, 1831] are found inside EPC-derived exosomes. Further, we have examined the expression levels of these miRNAs in plasma collected from patients experiencing severe sepsis and assessed for associations with the development of shock and organ failure. We hypothesized that patients who experience shock and organ failure will express higher levels of miRNAs that could reduce endothelial barrier integrity through gene inhibition and, conversely, express reduced levels of miRNAs that could enhance endothelial barrier integrity.

Methods

Subject recruitment and sample acquisition

We screened all new intensive care unit (ICU) admissions at a single tertiary-care academic hospital from July 2013 to February 2015 for the presence of severe sepsis based on the American College of Chest Physicians/Society of Critical Care Medicine consensus definition [1]. Additional inclusion criteria included age ≥ 18 years and admission into the ICU within the previous 24 hours. We excluded immunocompromised patients as defined by: immunosuppressive medication use, leukopenia, current hematologic malignancy, and history of stem cell transplant, and excluded patients transferred in from other hospitals if they had spent > 24 hours in an ICU at the time of screening. Patients who had transitioned to comfort measures only at the time of screening were further excluded. Healthy control subjects were recruited through local advertising. Informed consent for study participation and publication of results was obtained from all research subjects or their legally authorized representatives.

Consenting subjects had blood drawn via venipuncture or from pre-existing intravascular catheters. Blood samples from septic patients were collected within 24 hours of admission to the ICU. Samples were centrifuged at 3400 × g for 10 minutes and the plasma supernatant was collected and stored in aliquots at -80 degrees Celsius. Demographic and clinical information from septic patients was abstracted from the electronic medical record including the source and type of infection as well as variables required to calculate acute physiology and chronic health evaluation (APACHE) II scores. Clinical outcomes including occurrence of shock (defined by vasopressor use), occurrence of acute kidney injury [Acute Kidney Injury Network (AKIN) criteria], occurrence of acute respiratory distress syndrome (ARDS) by the Berlin definition [32], ICU and hospital length of stay, discharge destination and vital status were similarly captured. Basic demographics were recorded from healthy controls.

Human EPC isolation, culture and exosome analysis

Human EPCs were isolated from umbilical cord blood as previously described (Medina). Cells were cultured in EGM-2 medium (Lonza, Walkersville, MD, USA) containing 10 % of exosome-depleted fetal bovine serum (System Biosciences, Mountain View, CA, USA). Exosomes were isolated from EPC-conditioned medium using ExoQuick Exosome Precipitation Solution (System Biosciences) following the manufacturer’s instructions. MiRNAs were isolated by miRNeasy kits (Qiagen, Valencia, CA, USA) and analyzed by real-time polymerase chain reaction (RT-PCR).

Candidate miRNA selection

Using the combination of MeSH terms for “sepsis” and “microRNA”, we searched MEDLINE for articles that describe associations between the miRNA expression and sepsis. Each article was reviewed and associated miRNA were recorded and then searched individually in conjunction with sepsis (e.g., “miR-146a” and “sepsis”) in order to identify any additional references that associate miRNA expression and sepsis. In order to focus the investigation on miRNA with a high likelihood of relevance, we considered only miRNAs with at least two published references associated with sepsis to be potential candidates for investigation. These candidates were then cross-referenced with miRNA expression data from an array performed on human EPC-derived exosomes. MiRNAs that were not measured or in very low abundance in these exosomes were excluded, while the remaining miRNAs comprised the list of candidate miRNAs included in the analysis.

Real-time PCR

Plasma samples from septic and healthy control subjects and EPC-derived exosome contents each underwent real-time PCR analysis. Candidate miRNAs were isolated from plasma and exosome samples using miRNeasy serum/plasma kits and then amplified with miScript SYBR Green PCR kits and primers specific to each miRNA (Qiagen). The mean Cq of the healthy control subjects was used to normalize the Cqs for each miRNA. Delta Cqs were then converted to and presented as fold change compared to the healthy control mean expression values.

Bioinformatic analysis

Ingenuity Pathway Analysis (Qiagen) was used to examine the canonical pathways in which differentially expressed miRNAs in shock were involved. The software uses Fisher’s exact test to determine the statistical probability that a given canonical pathway is modulated by the inputted miRNA. Significant pathways are represented by the negative log of the p value; we a priori chose to only present pathways with a p value ≤ 0.001 corresponding to a negative log value of four. Subsequently, the miRNA target databases TargetScan [34] and MiRanda [35] were analyzed and both experimentally validated and predicted gene targets involved in canonical pathways of relevance were identified and used to manually construct a gene network for the differentially expressed miRNA.

Statistical analysis

Baseline characteristics of human subjects were compared between the healthy control, septic patients without shock, and septic patients with shock groups using analysis of variance (ANOVA) for continuous variables and the chi-squared test for categorical variables. Continuous clinical characteristics were compared between septic patients who experienced shock and those who did not using the Student’s t test or Wilcoxon rank sum test as appropriate while categorical variables were compared using the chi-squared or Fisher exact test. MiRNA expression is presented as a continuous fold change variable and compared between the two sepsis groups using the Wilcoxon rank sum test. Additionally, miRNA expression was compared between groups defined by the presence or absence of acute kidney injury and ARDS as well as between groups defined by an APACHE II score of less than versus greater than or equal to 25. Correlation between miRNA levels and APACHE II scores was further assessed for using Spearman’s correlation. Area under the curve (AUC) was estimated for each miRNA based on univariate logistic regression models comparing the subjects who experienced shock and those who did not. A multivariable logistic regression was also developed to determine the predictive performance of a combination of the candidate miRNAs. The AUC for the most predictive single miRNA was compared to the AUC from the multiple logistic regression model using Delong’s test for comparing nested AUCs. Bootstrap confidence intervals based on 1000 bootstrap samples were also estimated for all AUCs. All analyses were conducted in SAS v. 9.3 (SAS Institute, Cary, NC, USA). All aspects of this study were approved by the Institutional Review Board at the Medical University of South Carolina.

Results

A total of 228 patients with a clinical picture suggestive of severe sepsis were admitted to the medical or surgical ICUs during the study enrollment period. Of these, 12 (5 %) were deemed by the study team and the clinical team to not have sepsis after detailed review of the clinical history. Of the remaining 216 patients, 121 (56 %) were excluded because consent was unobtainable within the first 24 hours of presentation to an ICU. Further, 27 (13 %) patients were excluded for having an immunocompromised condition, and six (3 %) were excluded because they were receiving comfort measures only at the time of screening. The remaining 62 (29 %) were enrolled and included in the analysis in addition to 32 healthy control volunteers. Healthy control subjects were on average younger and more likely to be of white race (Table 1). Among septic subjects, those who developed shock were similar in age and race to those who did not but were more likely to be of male gender. The source of infection was similar between those who experienced shock and those who did not, as was the type of organism responsible for the sepsis. Subjects who experienced shock had no significant differences in their rates of mechanical ventilation, ARDS, or acute kidney injury as well as ICU or hospital lengths of stay; however, they did have a nonsignificant trend toward higher APACHE II scores at enrollment and a significantly higher mortality rate.

Table 1 Characteristics of study subjects

Expression of candidate miRNAs in human EPC exosomes

We identified 17 miRNAs with more than one published reference associating them with sepsis. Of these, four miRNAs were either not measured or expressed in very low levels in an array of human EPC-derived exosomes (data not shown) and were excluded from analysis while the remaining 13 miRNA were analyzed (Table 2). The expression levels of the candidate miRNA in human EPC-derived exosomes was determined by RT-PCR and displayed in Fig. 1. Expression levels are presented as fold changes from RNU6B expression as previously described [36, 37].

Table 2 Summary of candidate miRNA associated with sepsis
Fig. 1
figure 1

Expression of candidate miRNAs in human EPC-derived exosomes. Data normalized to the expression of RUN6B. EPC endothelial progenitor cells, miRNA microRNA

Differential expression of miRNAs in shock

The expression levels of the candidate miRNAs were measured in the plasma from healthy controls as well as from septic patients with and without shock using RT-PCR. The mean expression level was calculated from the healthy control group for each miRNA and used to normalize the expression of that miRNA for each septic subject such that data is presented as a fold change in expression compared to the mean healthy control values. Expression levels were compared between healthy controls (n = 32) and the entire sepsis population (n = 62) as well as between septic subjects with (n = 29) and without shock (n =33). Sepsis patients demonstrated significantly higher plasma expression of each miRNA (all p < 0.05, data not shown) except miR-150 (p = 0.14) and miR-486 (p = 0.58) when compared to healthy controls. MiR-15a and -27a were significantly underexpressed in septic subjects who experienced shock compared to those who did not (p = 0.0062 and p = 0.03, respectively) while miR-34a was overexpressed (p = 0.03) in the shock group (Fig. 2). Patients in shock also exhibited nonsignificant trends toward reduced expressions of miR-21 and miR-126 compared to the subjects who did not experience shock (p = 0.9 and p = 0.1, respectively). There were no significant differences in the expression of any other miRNAs between the two sepsis groups.

Fig. 2
figure 2

Plasma expression levels of miRNAs associated with sepsis in healthy controls (n = 32) and septic patients with (n = 29) and without shock (n = 33). Data presented as a fold change compared to the median value of the healthy control population for each miRNA. Box plots are displayed where the horizontal bar represents the median, the box represents the IQR and the whiskers represent the maximum and minimum values. Comparisons made by Wilcoxon rank sum test. HC healthy control, miRNA microRNA, IQR interquartile range

In a separate analysis, miRNA levels were compared between septic subjects whose clinical course was complicated by acute kidney injury or ARDS and between subjects with high (≥25) or low (< 25) APACHE II scores. In total, 38 of 62 (61 %) subjects experienced acute kidney injury (defined as AKIN stage I or higher). Of these 38, only 18 (47 %) subjects had experienced vasopressor-dependent shock, demonstrating only modest overlap between the groups defined by the presence of shock and the presence of acute kidney injury. However, similar to the subjects who experienced shock, those who experienced acute kidney injury exhibited significantly lower levels of plasma miR-15a compared to those who experienced no acute kidney injury (p < 0.0001, data not shown). There were no significant differences in the expression levels of other miRNAs based on the presence or absence of acute kidney injury. Additionally, there were no associations or correlations between miRNA levels and presence of ARDS or APACHE II scores.

The combination of differentially expressed miRNA predicts the development of shock

Logistic regression was used to determine associations between miRNA expression and shock. The area under the curve (AUC) values for individual miRNAs ranged between 0.66 and 0.70 (Table 3). MiR-15a was the most predictive single miRNA for distinguishing between sepsis patients with and without shock with an AUC of 0.70 [95 % confidence interval (CI) 0.57–0.84]. The final multiple marker model included miR-15a, -27a, and -34a. The receiver operating characteristics curves for miR-15a and for the multiple marker model are shown in Fig. 3. Although the AUC for the multiple marker model was larger than any individual marker [AUC = 0.78 (95 % CI 0.66–0.90)], there was not a significant difference in the AUC between it and miR15a (p = 0.090).

Table 3 Area under the curve (AUC) (95 % confidence interval) for individual miRNAs and for a multivariable logistic regression model
Fig. 3
figure 3

Receiver operating characteristics curve for miR-15a (orange) and for the multivariable logistic regression model including miR-15a, miR-27a, and miR-34a (green)

In silico analyses of the differentially expressed miRNA

MiRNA-15a, -27a, and -34a were input into Ingenuity Pathway Analysis in order to predict the canonical pathways that may be differentially regulated in septic subjects who experienced shock. Twenty different pathways met the predetermined significance level of a negative log of the p value ≥ 4 (Fig. 4). Of these 20, four pathways appeared to be particularly relevant to the endothelial response to sepsis including LPS-stimulated MAP kinase signaling, cell cycle: G1/S checkpoint, vascular endothelial growth factor (VEGF) signaling, and myc-mediated apoptosis signaling.

Fig. 4
figure 4

Canonical pathways predicted by Ingenuity Pathway Analysis to be modulated by miR-15a, -27a, and -34a. Data presented as the negative log of the p value of the Fisher’s exact test. Shaded bars represent pathways of potential relevance to endothelial dysfunction in sepsis

Review of the TargetScan and miRanda databases identified 20 total genes that have been experimentally validated (solid lines) to be targets of miR-15a, -27a, or -34a and are also associated with pathways of potential relevance in sepsis (Fig. 5). These pathways include those identified in the canonical pathway analysis (cell cycle regulation, apoptosis, and LPS-stimulated MAP kinase signaling) as well as the nuclear factor kappa B (NF-κB) signaling pathway and a broader pathway of endothelial barrier integrity that includes VEGF signaling. Additional genes that are predicted targets of these miRNA and are included in these pathways are also displayed (dashed lines).

Fig. 5
figure 5

Gene target network of miR-15a, -27a, and -34a in pathways of relevance to endothelial dysfunction in sepsis. Arrows represent validated (solid) or predicted (dashed) targets of a miRNA. miRNA microRNA

Discussion

The results of this study demonstrate that the expression of candidate miRNAs with known associations with sepsis is altered in patients with septic shock. These data demonstrate that miR-15a, -34a, and -27a were all differentially expressed in patients whose course was complicated by shock and their combination was able to discriminate which patients had or developed shock with reasonable accuracy. In silico analyses predict that these three miRNAs modulate several pathways important to endothelial cell function including: cell cycle regulation, apoptosis, barrier integrity, lipopolysaccharide (LPS)-mediated signaling, and NF-κB signaling. Inside of these pathways, several gene targets have been identified that may represent key mediators in the development of endothelial dysfunction and progression to shock.

Since the initial discovery of extracellular miRNA, investigators have postulated that they provide a mechanism for cell-to-cell communication through manipulation of target cell gene expression [10]. MiRNAs are known to circulate in the plasma either enveloped in a vesicular structure such as an exosome, microvesicle or apoptotic body [10, 11, 38] or bound to protein such as argonaute 2 or high-density lipoprotein (HDL) [39, 40]. Endothelial cells can communicate with each other or with other cell types through the release of membrane-bound miRNAs, which are internalized by recipient cells leading to an alteration of gene expression [11, 12]. Thus, the expression patterns of extracellular miRNAs that modulate endothelial function and inflammatory signaling may provide key insights into mechanisms that contribute to endothelial activation and injury in the setting of severe sepsis. Through the identification of differentially expressed miRNAs in patients who developed shock, these data provide new directions of exploration into both mechanistic discovery and therapeutic intervention.

Although the data presented here represent only associations, there are several potential mechanisms by which the differential expression or miR-15a, -27a, and -34a could impact the development of endothelial dysfunction and shock. First, both miR-15a and miR-27a are known to or are predicted to target and inhibit genes that increase vascular permeability in the setting of sepsis including VEGFA, VEGFC and MYLK [4144]. Therefore, reduced levels of circulating miR-15a and miR-27a could disinhibit these genes and contribute to the development of shock. Alternatively, miR-34a targets and inhibits BCL2 and SIRT1, which have both been identified as important negative regulators of apoptosis and cellular senescence in the endothelium [45, 46]. Thus, increased levels of circulating miR-34a could be contributing to the endothelial dysfunction in shock by augmenting apoptosis and senescence in response to cytokine stimuli. Finally, miR-15a may target several members of the NF-κB pathway and reduced circulating miR-15a could functionally augment NF-κB signaling leading to increased inflammatory cytokine production and increased endothelial injury.

In addition to providing mechanistic insight into the endothelial dysfunction of septic shock, the differential expression of miR-15a, -27a, and -34a may also offer prognostic biomarker capability. Unlike genomic DNA, which is static, RNA expression can dynamically change over healthy and diseased states and, thus, can provide real-time information regarding cellular function. And, as protein repression is a downstream consequence of miRNA function, changes in miRNA expression may precede changes in protein expression. Accordingly, miRNAs that are associated with the development of shock in patients with sepsis may provide an early glimpse into an individual’s risk at the time of initial presentation. Thus, rapid, automated analysis of plasma miRNAs could represent a useful prognostic biomarker with which to risk stratify patients with severe sepsis. Such a tool could be used to identify those at greatest risk for impending hemodynamic compromise potentially leading to more aggressive early intervention or changes in triage practices.

This study has limitations. As stated above, our data provide only associations between plasma miRNA levels and shock; therefore, we cannot determine if the differential expression of these miRNAs contributes to the development of shock or is a response to shock. In addition, our decision to examine a larger array of candidate miRNA limited our ability to confirm statistical significance with multiple comparisons testing. Future work will focus on validating the differential expression of miR-15a, miR-27a, and miR-34a in independent cohorts. Although all of the plasma samples from sepsis patients were collected within the first 24 hours of admission, these data are unable to determine the prognostic capabilities of these miRNA if measured immediately at the time of initial presentation. Future studies that examine miRNA expression at that time point will help to clarify their prognostic utility. Our data are further limited by our inability to identify the cellular source of the analyzed miRNA. A variety of cells exposed to plasma are known to release membrane-bound miRNA including lymphocytes, neutrophils, platelets, endothelial cells, and endothelial progenitor cells [11, 13, 14, 47, 48] and individual miRNAs are known to be released by numerous different cell types [49]. Further, comparisons between the miRNA expression in cells and their daughter exosomes has revealed markedly different miRNA expression patterns between the two compartments suggesting a selective export mechanism [10, 13, 50]. In combination, these characteristics create a significant challenge to determining the exact cellular source of circulating miRNA. Finally, this investigation is limited by the inability to study the downstream targets of the differentially expressed miRNAs in vivo. The vast majority of the known or predicted targets code for intracellular proteins, which would necessitate biopsy of tissue in order to analyze their expression in the endothelium in vivo. As patients admitted with severe sepsis uncommonly undergo tissue biopsy, this represents a limitation to our analysis. A notable exception is VEGFA, which is targeted by miR-15a and is secreted extracellularly. When analyzed, no association could be identified between VEGFA and miR-15a levels in subjects’ serum (data not shown). It is unclear from the current sample size if this lack of association is accurate or representative of type II error in setting of the statistical noise inherent to in vivo analysis of the critically ill. Since this also represents a single point in time in a disease with a protracted course, a time course study of serum miR-15a and VEGFA levels is warranted to definitively establish whether an association between the two exists.

Conclusions

Altered plasma expression levels of miR-15a, -27a, and -34a are associated with the development of shock in patients with severe sepsis. These miRNA target cellular pathways that are critical to endothelial homeostasis including cell cycle regulation, apoptosis, cell layer permeability, and inflammatory response signaling. Future work will include earlier measurement of miRNA at the time of presentation to determine their prognostic capabilities as well as using in vitro and animal models of sepsis to clarify the potential roles that these miRNA and their targets play in the development of endothelial dysfunction and shock.

Key messages

  • Endothelial dysfunction is an important hallmark of the development of shock

  • MicroRNA-15a, -27a, and -34a are differentially expressed in the plasma of septic patients who develop shock

  • The expression of these microRNAs predict the presence of shock with very good accuracy

  • In silico analyses predict that these microRNAs target and inhibit a number of genes that regulate the cell cycle, apoptosis, NF-κB signaling, LPS-stimulated MAP kinase signaling, and intercell permeability of endothelial cells.