Background

Legionella is a Gram-negative bacterium that thrives in warm and humid environments [1]. It is difficult to control owing to its resistance to disinfectants, especially in artificial aquatic environments [2].Currently, the genus Legionella includes more than 58 species and 70 distinct serogroups. All species are susceptible to legionellosis, among which Legionella pneumophila (L. pneumophila) serogroup 1 is the most prevalent pathogenic bacterium [3]. Legionellosis may manifest as Pontiac fever, which is characterized by respiratory flu, and Legionnaires’ disease which is characterized by a serious lung infection and multisystem damage. Pontiac fever is a self-limited febrile illness, whereas Legionnaires’ disease is a severe form of pneumonia with a high fatality rate [4].

Legionellosis is caused by the inhalation of aerosols contaminated with Legionella spp. including L. pneumophila observed in artificial water sources such as hot tubs, cooling towers, showers, air conditioning and plumbing systems [1]. Approximately 90% of the diseases caused by Legionella can be prevented by better water control [5]. Therefore, it is crucial to rapidly assess the number of live or dead microbes present in water samples for public health, especially in high-risk environments such as hospitals and nursing homes. [6]. To reduce the mortality of legionellosis, it is necessary to develop an effective and rapid method to detect Legionella, especially L. pneumophila from environmental sources [7].

Currently, there are two main ways to detect L. pneumophila which are the culture and polymerase chain reaction (PCR) methods [8]. Although the agar plate culture has long been considered the gold standard for detecting L. pneumophila from primary samples, it does have inevitable limitations [9]. First, it takes 10–14 days to have visible L. pneumophila colonies [10]. Second, it requires both hard work and professional skills to identify L. pneumophila correctly. Differences in test conditions and technique may influence the results [11]. Moreover, other microorganisms in the specimen may inhibit the growth of L. pneumophila, resulting in false-negative results [12]. In contrast, PCR is a faster, easier and more accurate method to detect L. pneumophila in environmental samples, which is also applicable to large-scale detections [13]. Furthermore, on-site PCR allows for robust and straightforward quantification of L. pneumophila species in the field for routine monitoring, rapid response and effective control of infectious outbreaks [14].

Considering this situation, we conducted this study and evaluated the efficiency of PCR for L. pneumophila according to Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) diagnostic test accuracy guidelines.

Methods and materials

Patients were not involved in this study. Therefore, institutional review body permission was not required. All our review processes adhered to the PRISMA statement guidelines (http://www.prisma-statement.org/).

Search strategy

Articles about Legionella and PCR were systematically searched for by two reviewers. All data were available in PubMed, Embase, Web of Science, Cochrane Library, WanFang, China National Knowledge Infrastructure and Chinese Biomedical Literature database before February 2021. The keywords ‘PCR, Polymerase Chain Reactions’ and ‘Legionella’ were used for the advanced search (see Additional file 1). Geographical restrictions were not applied in these articles.

Screening criteria of included studies

Two researchers independently screened the title/abstract, followed by the full text, using predetermined reviewing criteria designed by the third reviewer. The final decision was made by the third reviewer when there was a dispute between two reviewers.

The inclusion criteria were as follows: (1) PCR was the detection method; (2) Legionella was detected; (3) environmental samples were included; (4) the study was original research and related to diagnostics.

The exclusion criteria were as follows: (1) duplicate studies; (2) culture was not the gold standard; (3) case reports, conference summaries, reviews and editorials; (4) visual four-fold tables; (5) sample size < 20; (6) Legionella spp. without L. pneumophila; (7) the language was not English.

Data extraction

The investigators carefully read the included articles. Relevant data were extracted from the studies, including publication information (e.g., the first author, publication time, country, sample source, PCR type and targeted gene), and arranged made into 2 × 2 fourfold tables filled with true-positive (TP), true-negative (TN), false-positive (FP), and false-negative (FN) results. Investigators independently extracted the data. When there was a discrepancy in the extracted data, the two investigators in charge discussed and decided, or the third investigator was asked.

Quality assessment

Two review authors independently assessed of the risk of bias to evaluate the quality, using the Quality Assessment of Diagnosis Accuracy Studies-2 (QUADAS-2) guidelines [15]. The risk of bias in each part was rated ‘high’, ‘unclear’, or ‘low’. Differences were resolved through discussion with the third reviewer. The quality figures were created by the Review Manager version 5.3.

Statistical analysis

We obtained the numbers of TP, FP, FN and TN results from each enrolled study. Using a random-effects model, we calculated the following indicators of detection accuracy: sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR) and their 95% confidence intervals (CIs). The subject operating characteristic (SROC) curve and the area under the SROC curve (AUC) were used to summarise the overall test performance.

Heterogeneity was identified from a threshold effect with the P value of Spearman correlation. Meanwhile, the non-threshold effect was assessed based on DOR. We conducted a meta-regression analysis and generated a bivariate box plot to evaluate the outliers and describe the diagnosis value. Publication bias was tested using Deeks’ funnel plot asymmetry. P value < 0.05 was considered statistically significant. MetaDiSc 1.4 and Stata 15.0 were used to analyse the results.

Results

Eligible studies and characteristics

A total of 7951 publications were retrieved based on the search strategy. After we eliminated the repetitive items, 3872 articles remained. For their uncorrelated titles or abstracts, 3809 studies were removed. Following a thorough review of 63 studies, 47 articles were excluded for various reasons (see Additional file 2). Finally, 16 qualified articles were included [7, 9, 13, 16,17,18,19,20,21,22,23,24,25,26,27,28]. A total of 18 fourfold tables were extracted from these included articles. The characteristics of the studies included were presented in Table 1.

Table 1 Characteristics of the included studies (N = 16)

Quality assessment

The overall quality of the 16 included studies was shown in Figs. 1 and 2. Considering that the thresholds of the index employed were not predetermined, seven studies (43.75%) were at high risk of bias in the index test domain. Only one study (6.25%) was rated as ‘high risk’ in the flow and timing domain because not all cases were included in the analysis.

Fig. 1
figure 1

Methodological quality summary of included studies

Fig. 2
figure 2

Methodological quality graph of included studies

Results of PCR

The sensitivity and specificity of PCR in the detection of L. pneumophila was 0.94 (95% CI 0.92–0.95) and 0.72 (95% CI 0.70–0.73), respectively (Figs. 3 and 4). The PLR and NLR was 2.73 (95% CI 2.07–3.60) and 0.12 (95% CI 0.07–0.22), respectively (Figs. 5 and 6). The DOR was 22.85 (95% CI 11.06–47.20) in Fig. 7.

Fig. 3
figure 3

Sensitivity of polymerase chain reaction (PCR) in the detection of L. pneumophila

Fig. 4
figure 4

Specificity of polymerase chain reaction (PCR) in the detection of L. pneumophila

Fig. 5
figure 5

Positive likelihood ratio (PLR) of polymerase chain reaction (PCR) in the detection of L. pneumophila

Fig. 6
figure 6

Negative likelihood ratio (NLR) of polymerase chain reaction (PCR) in the detection of L. pneumophila

Fig. 7
figure 7

DOR of PCR in the detection of L. pneumophila

Threshold effect analysis

It can be observed from the SROC curve (Fig. 8) that there was no ‘shoulder-arm’ distribution. In addition, the Spearman correlation coefficient was -0.446 (< 0.6), and the P value was 0.064 (> 0.05) (see Additional file 3). The automatically generated I-square (I2) was interpreted that 50–90% represents substantial heterogeneity, and 75–100% means considerable heterogeneity [29]. Therefore, we concluded that it was not a threshold effect. High heterogeneity was detected as follows (Figs. 3, 4, 5, 6, 7): sensitivity, I2 = 73.8%; specificity, I2 = 94.0%; PLR, I2 = 94.9%; NLR, I2 = 79.0% and DOR, I2 = 80.0%.

Fig. 8
figure 8

Summary receiver operating characteristic curve

SROC curve

The AUC was 0.7884 in the SROC curve. These indicated a considerable diagnostic accuracy of PCR for L. pneumophila (Fig. 8).

Meta-regression analysis and bivariate box plot

A statistical association with sensitivity was observed in the macrophage infectivity potentiator (mip) gene (P < 0.05) in Fig. 9. For the bivariate boxplot in Fig. 10, two floating points were out of the circles suggesting heterogeneity [9, 20].

Fig. 9
figure 9

Meta-regression for heterogeneity analysis

Fig. 10
figure 10

Bivariate box plot for heterogeneity analysis

Publication bias

In Deeks’ funnel plot (Fig. 11), most points were distributed symmetrically along both sides, and the P value was 0.45 (> 0.1), indicating no publication bias in the study.

Fig. 11
figure 11

Deeks’ funnel plot asymmetry test

Discussion

L. pneumophila, the most important causative agent of legionellosis, is a harmful pathogen that is often found in water systems [30, 31]. The overall case-fatality rate of legionellosis is 5–14%, but 76% when inappropriate antibiotics were used [32]. Therefore, it is of great importance to establish a standardised method for early and rapid environmental detection of L. pneumophila to prevent outbreaks of infection in hospitals.

Culture has been recognised as the gold standard for the detection of L. pneumophila; however, it is not widely used in environmental detection because it is time-consuming and limited by the culture process which is affected by other rapid propagation strains [6]. As an alternative method, PCR provides a faster turnabout time, a higher level of sensitivity and the possibility of early rapid detection. However, compared with the culture method, the cost is higher. In addition, there may be false-positive results when the amount of L. pneumophila is very small and not pathogenic [33].

Our analysis revealed a sensitivity of 0.94 (95% CI 0.92–0.95) and a relatively low specificity of 0.72 (95% CI 0.70–0.73) for PCR detection of L. pneumophila. The reason for the low specificity may be that PCR analyses amplified DNA in environmental samples, including DNA from dead bacteria and living bacteria that cannot be cultured. Moreover, when environmental samples are cultured, L. pneumophila can be inhibited by other overgrown bacteria owing to its specific growth requirements. Furthermore, L. pneumophila cells may reduce since the acid buffer or heat treatment is used in the sample preparation [20, 23, 25]. Dead bacteria can be detected by PCR, which will result in false-positive results. The presence of PCR inhibitors in water samples can lead to false-negative results [21].

In terms of heterogeneity, it was concluded that high heterogeneity was caused by the non-threshold effect rather than the threshold effect. The mip gene indicated potential heterogeneity in sensitivity analysis but not in specificity analysis. Moreover, subgroup analysis was not conducted owing to insufficient samples, although samples were obtained from different sources such as cooling towers, ship water and diverse water supply systems. [26,27,28].

Different temperatures, acid–base environments and disinfection conditions can influence the growth of L. pneumophila in water samples, resulting in heterogeneity. Furthermore, PCR cannot distinguish between dead bacteria and live bacteria, therefore, diverse water samples may exhibit different specificities to PCR, as described previously [34]. In addition, we speculate that the test inspectors and experimental conditions may have contributed to heterogeneity.

In this study, we found two studies exhibited substantial heterogeneity, according to the bivariate boxplot. When PCR was performed on the contaminated samples including dead bacteria and bacteria with low viability, it resulted in a higher sensitivity and a lower specificity [9, 20]. To quantify the viable bacteria before PCR, DNA was treated with ethidium or propidium monoazide for amplification, which improved sensitivity [9].

However, our study had some limitations. First, the disagreement between the two reviewers on included studies and extracted data was resolved, but it cannot be quantified with Cohen's Kappa score and introduced selection bias. Second, exclusion of grey literature and non-English studies could introduce selection bias. Last, the results may be influence by the different primers and probes used.

Conclusions

Inconclusion, PCR has been considered beneficial for L. pneumophila in environmental samples owing to its rapid turn-around time and high sensitivity, and the ability to detect small amounts of target nucleic acids in samples. The results have proven to be crucial for environmental public health, especially for environmental surveillance in hospitals and large water systems. PCR may enable prevention and early diagnosis of Legionellosis. Therefore, efficient and convenient PCR may be a major laboratory diagnostic tool for epidemic prevention of Legionellosis.