The diagnosis of heparin-induced thrombocytopenia (HIT) depends upon clinical suspicion and laboratory testing. Unfortunately only a limited number of laboratories in the world are now capable of performing the gold-standard platelet serotonin release assay to determine whether the antibodies are pathogenic. Most laboratories, as with Lasocki and colleagues [1], therefore rely on commercially available enzyme immunoassays (EIAs) – which have a high sensitivity due to a high negative predictive value, but have variable specificity as they also detect IgA and IgM antibodies, which are probably not pathogenic [2]. Functional assays of platelet aggregation are therefore often used to confirm EIA results.

Heparin binds to surface-bound platelet factor 4 (PF4) and, although used as an anticoagulant, paradoxically causes platelet activation. When patients are first exposed to heparins, therefore, typically there is a mild fall in the peripheral platelet count [3]. If patients are exposed to a critical amount of heparin, a stoichiometric ratio of 27 IU heparin to 1 mg PF4, then cross-linking of surface-bound PF4 leads to conformational change and to the exposure of novel epitopes, with the potential to form pathogenic IgG1 antibodies to the heparin/PF4 complex. Fortunately, the incidence of HIT remains low in the intensive care unit (0.3% to 0.5%) [4], probably because most patients do not receive sufficient heparin to achieve the critical ratio to lead to novel epitope exposure. Using an initial priming solution containing 10,000 IU heparin, followed by a heparin infusion, may therefore have accounted for the increased incidence of HIT (8%) reported [4]. Heparin/PF4 antibodies occur most commonly following cardiac and vascular surgery, when patients receive large doses of heparin intraoperatively [5].

The clinical sequalae of developing heparin/PF4 antibodies detected by EIA varies widely [6] – ranging from being totally asymptomatic to repeated clotting of the extracorporeal circuit [7], to increased venous thrombosis at the sites of indwelling central venous catheters [8], and to sudden collapse due to pulmonary emboli or pseudopulmonary embolus syndrome following intravenous heparin administration [9].

This disparity between the detection of heparin/PF4 antibodies by EIA and the clinical sequalae has led to the concept of separating HIT from heparin-induced thrombo-cytopenia and thrombosis (HITTS), and some authors have questioned the reliability of EIAs in detecting pathologically relevant antibodies [2]. EIA optical density results have been compared recently with the gold-standard platelet serotonin release; taking a 50% serotonin release as a positive heparin/PF4 antibody result, this corresponded to an EIA optical density ≥ 1.4 [10]. Even so, in Lasocki and colleagues' study, the optical density EIA results were not greater in the two patients with thrombotic complications, and there was no correlation between EIA results within the HIT-positive group with thrombocytopenia or circuit clotting [1]. Heparin administration and dosing, and also the presence of other antibodies – including those directed to platelet cytokines and other surface receptors – and platelet activation may therefore be important in determining clinical outcomes.

Once HIT is clinically suspected it is imperative that all heparin administration is withdrawn [11], including heparin catheter locks and flushes [9], and another systemic anticoagulant is substituted [12]. Patients in this series were successfully anticoagulated with danaparoid [12], and not only did hemofilter circuit survival increase but so did urea clearances. This observation would suggest that the patients with HIT had increased platelet and thrombus deposition within the hemofilter, therefore causing membrane fouling and reduced clearances [13]. Interestingly, circuit survival and clearances were better for the HIT-positive group anticoagulated with danaparoid, compared with the HIT-negative group who remained on heparin. This difference may have been due to so-called heparin resistance associated with reduced antithrombin in the HIT-negative patient group.

The increased incidence of EIA heparin/PF4 antibodies reported in the present study was probably due to the larger doses of heparin used in priming the hemofilter circuit, and heparin exposure should therefore be minimised in the intensive care unit to reduce the incidence of HIT. The 4T (thrombocytopenia, timing, thrombosis, and other causes) pre-test probability scoring system did not predict which patients with early hemofiltration circuit clotting subsequently had positive EIA tests for HIT antibodies (Table 1). Whereas previous patient series have suggested early circuit clotting was associated with vascular access problems, the present study showed that heparin/PF4 antibodies caused clotting within the hemofilter, and that danaparoid was a more effective extracorporeal anticoagulant than heparin in the HIT-negative group. HIT should therefore be considered in cases of very early or repeated circuit clotting.

Table 1 The 4T (thrombocytopenia, timing, thrombosis, and other causes) pretest probability of heparin-induced thrombocytopenia [6]