Background
Ebstein's anomaly (EA) is a rare but clinically important congenital heart disease with potential affection of right ventricular(RV), right atrial (RA), left ventricular (LV) and left atrial (LA) function that may play a role in heart failure development. Thus, we sought to assess quantitative atrial and ventricular function in EA with CMR feature tracking, and to correlate changes in biatrial and biventricular performance with the severity of disease and clinical parameters of heart failure.
Methods
Atrial and ventricular deformation parameters were calculated from myocardial feature tracking (2D CPA MR, TomTec Unterschleissheim, Germany) from 30 EA and 20 healthy control subjects at 1.5 Tesla. RA and LA performance was characterized using longitudinal strain and strain rate parameters quantifying reservoir function (total strain [Ells], peak positive SR [SRs]), conduit function (passive strain [Elle], peak early negative SR [SRe]) and booster pump function (active strain [Ella], late peak negative SR [SRa]). Ventricular performance was characterized using RV and LV global longitudinal strain (Ell) and LV circumferential and radial short axis strain (Ecc and Err). Additionally, volumetric measurements (QMass, Medis, Leiden, The Netherlands) for all cardiac chambers including the Total right/left volume-index and heart failure markers (BNP, NYHA class) were quantified.
Results
RA reservoir and booster pump function were significantly impaired in the EA group as compared to controls using strain and volume metrics (see table 1) while conduit function was not different based on volumes. Changes in RA performance correlated significantly with markers of heart failure (NYHA, BNP and Total R/L-Volume Index). LA function in EA patients was also significantly impaired with atrial contractile function correlating with NYHA class. Furthermore, EA patients exhibited an impaired RV function (see table 1) also with a significant correlation with heart failure markers (RV Ell with NYHA class: r = 0.466, p = 0.012), whereas LV parameters only showed a non-significant trend towards reduced performance.
Conclusions
Right atrial function is impaired in EA and can be quantified using CMR-FT. In combination with reduced quantitative RV longitudinal strain in the presence of preserved RV-EF, these quantitative changes may potentially represent early stages in heart failure development in EA. This is underpinned by a close correlation of decreased RA and RV deformational function with heart failure parameters such as NYHA, BNP and Total R/L-Volume Index. LA function is also impaired in EA, while LV function is still normal.
We suggest that in EA patients, CMR derived RA function and RV longitudinal strain may be used as more sensitive markers to detect early deterioration of right heart function. Moreover, LA deformation should be monitored for early detection of left heart dysfunction. Incorporating these measures into CMR assessment may help to improve clinical management of EA patients.
Author information
Authors and Affiliations
Rights and permissions
This article is published under an open access license. Please check the 'Copyright Information' section either on this page or in the PDF for details of this license and what re-use is permitted. If your intended use exceeds what is permitted by the license or if you are unable to locate the licence and re-use information, please contact the Rights and Permissions team.
About this article
Cite this article
Steinmetz, M., Broder, M., Kowallick, J.T. et al. Atrio-ventricular mechanics and heart failure in Ebstein's anomaly - a cardiac magnetic resonance study. J Cardiovasc Magn Reson 18 (Suppl 1), O119 (2016). https://doi.org/10.1186/1532-429X-18-S1-O119
Published:
DOI: https://doi.org/10.1186/1532-429X-18-S1-O119