Optimization of the cavity beam-position monitor system for the Shanghai soft X-ray free-electron laser user facility

  • Published:
Nuclear Science and Techniques Aims and scope Submit manuscript

Abstract

To achieve high-efficiency operation of the high-gain free-electron laser (FEL), the electron beams and radiated photon beams need to be overlapped precisely and pass through the entire undulator section. Therefore, a high-resolution beam-position monitor (BPM) is required. A cavity BPM (CBPM) with a resonant cavity structure was developed and used in the Shanghai Soft X-ray FEL (SXFEL) test facility and can achieve a position resolution of \(< {1}\upmu \mathrm{m}\). The construction and operation of the SXFEL user facility also bring about higher requirements for beam-position measurement. In this case, the factors that affect the performance of the CBPM system were further analyzed. These included the amplitude and phase stability of the local oscillator, stability of the trigger signal, performance of the radio frequency front-end, signal processing electronics, and signal processing algorithms. Based on the upgrade and optimization of the system, a beam test platform was built at the end of the linear acceleration section of the SXFEL, and the experimental results show that the position resolution of the system can reach 177 nm at a bunch charge of 500 pC, and the dynamic range is controlled within \(\pm {300}\upmu \mathrm{m}\), and the relative measurement uncertainty of the bunch charge can reach 0.021\(\%\), which are significant improvements compared to the attributes of the previous system.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18
Fig. 19
Fig. 20
Fig. 21

Similar content being viewed by others

References

  1. U. Bergmann, J. Corlett, S. Dierker et al., Science and technology of future light sources: a white paper. SLAC National Accelerator Lab (No. SLAC-R-917), (2009). https://doi.org/10.2172/947109

  2. Z. Zhao, D. Wang, Q. Gu et al., SXFEL: a soft X-ray free electron laser in China. Synchrotron Radiat. News 30(6), 29–33 (2017). https://doi.org/10.1080/08940886.2017.1386997

    Article  ADS  Google Scholar 

  3. C. Feng, D. Huang, H. Deng et al., A single stage EEHG at SXFEL for narrow-bandwidth soft X-ray generation. Sci. Bulletin 61(15), 1202–1212 (2016). https://doi.org/10.1007/s11434-016-1140-9

    Article  ADS  Google Scholar 

  4. T. Tanaka, H. Kitamura, T. Shintake, Consideration on the BPM alignment tolerance in X-ray FELs. Nucl. Instrum. Meth. A 528(1), 172–178 (2004). https://doi.org/10.1016/j.nima.2004.04.040

    Article  ADS  Google Scholar 

  5. V. Sargsyan, Comparison of stripline and cavity beam position monitors. Tech. Rep. 2004-03. https://cds.cern.ch/record/732356/files/cm-p00047837.pdf

  6. D.H. Whittum, Y. Kolomensky, Analysis of an asymmetric resonant cavity as a beam monitor. AIP Rev. Sci. Instrum. 70, 2300 (1999). https://doi.org/10.1063/1.1149756

    Article  ADS  Google Scholar 

  7. X.Y. Liu, F.F. Wu, T.Y. Zhou et al., Design and offline testing of a resonant stripline beam position monitor for the IRFEL project at NSRL. Nucl. Sci. Tech. 31, 57 (2020). https://doi.org/10.1007/s41365-020-00778-7

    Article  Google Scholar 

  8. R. Lill, W. Norum, L. Morrison et al., Design and performance of the LCLS cavity bpm system. in: 2007 IEEE particle accelerator conference (PAC), IEEE, 2007, pp. 4366-4368. https://doi.org/10.1109/PAC.2007.4440010

  9. S. Smith, S. Hoobler, R.G. Johnson, et al., Commissioning and performance of LCLS cavity BPMs. in: 2009 IEEE particle accelerator conference (PAC), 2009, pp. 754-756. https://accelconf.web.cern.ch/PAC2009/papers/tu3grc05.pdf

  10. H. Maesaka, H. Ego, S. Inoue et al., Sub-micron resolution RF cavity beam position monitor system at the SACLA xfel facility. Nucl. Instrum. Meth. A 696, 66–74 (2012). https://doi.org/10.1016/j.nima.2012.08.088

    Article  ADS  Google Scholar 

  11. M. Stadler, R. Baldinger, R. Ditter et al., Beam test results of undulator cavity BPM electronics for the European XFEL. Proceedings of IBIC2012, Tsukuba, Japan (JACoW, Tsukuba, Japan, 2012, pp. 404-408). https://accelconf.web.cern.ch/IBIC2012/papers/tupa27.pdf

  12. M. Stadler, R. Baldinger, R. Ditter et al., Low-Q cavity BPM electronics for E-XFEL, Flash-II and Swiss-FEL, Proceedings of IBIC2014, Monterey, CA, USA (JACoW, Monterey, CA, USA, 2014, pp. 670-674). https://accelconf.web.cern.ch/ibic2014/papers/wepd12.pdf

  13. B. Keil, R. Baldinger, R. Ditter et al., First beam commissioning experience with the SwissFEL cavity BPM system. Proceedings of IBIC2017, Grand Rapids, MI, USA (JACoW, Grand Rapids, MI, USA, 2017, pp. 251-254). https://doi.org/10.18429/JACoW-IBIC2017-TUPCF17

  14. Y. Inoue, H. Hayano, Y. Honda et al., Development of a high-resolution cavity-beam position monitor. Phys. Rev. Accel. Beams 11, 062801 (2008). https://doi.org/10.1103/PhysRevSTAB.11.062801

    Article  ADS  Google Scholar 

  15. Y.I. Kim, R. Ainsworth, A. Aryshev et al., Cavity beam position monitor system for the Accelerator Test Facility 2. Phys. Rev. Accel. Beams 15, 042801 (2012). https://doi.org/10.1103/physrevstab.15.042801

    Article  ADS  Google Scholar 

  16. J. Chen, Y.-B. Leng, L.-Y. Yu et al., Beam test results of high Q CBPM prototype for SXFEL. Nucl. Sci. Tech. 28, 51 (2017). https://doi.org/10.1007/s41365-017-0195-x

    Article  Google Scholar 

  17. J. Chen, R.-X. Yuan, Y.-B. Leng et al., Cavity beam position monitor system for Shanghai Soft X-ray Free Electron Laser. Atomic Energy Science and Technology 54, 1931–1939 (2020).https://doi.org/10.7538/yzk.2019.youxian.0697((in Chinese))

  18. R. Lorenz, Cavity beam position monitors, in AIP conference proceedings 451, 53 (1998). https://doi.org/10.1063/1.57039

  19. S. Walston, S. Boogert, C. Chung et al., Performance of a high resolution cavity beam position monitor system. Nucl. Instrum. Meth. A 578, 1–22 (2007). https://doi.org/10.1016/j.nima.2007.04.162

    Article  ADS  Google Scholar 

  20. W. Schnell, Common-mode rejection in resonant microwave position monitors for linear colliders. Tech. Rep. (1988). https://cds.cern.ch/record/189450/files/198808171.pdf

  21. J. Chen, Y.B. Leng, L.Y. Yu et al., Study of the crosstalk evaluation for cavity BPM. Nucl. Sci. Tech. 29, 83 (2018). https://doi.org/10.1007/s41365-018-0418-9

    Article  Google Scholar 

  22. ANALOG DEVICES Ltd,https://www.analog.com/cn/parametricsearch/10826/

  23. L. Lai, Y. Leng, X. Yi et al., DBPM signal processing with field programmable gate arrays. Nucl. Sci. Tech. 22(3), 129–133 (2013). https://doi.org/10.13538/j.1001-8042/nst.22.129-133

    Article  Google Scholar 

  24. L. Lai, F. Chen, J. Chen et al., Design and performance of digital BPM processor for DCLS and SXFEL. Proc. of IPAC2017, Copenhagen, Denmark (JACoW, Copenhagen, Denmark, 2017, pp. 338-340). https://doi.org/10.18429/JACoW-IPAC2017-MOPAB092

  25. L. Lai, F. Chen, Y. Leng et al., The Development and applications of digital BPM signal processor on SSRF. Proc. of IBIC2018, Shanghai, China (JACoW, Shanghai, China, 2018, pp. 147-149). https://doi.org/10.18429/JACoW-IBIC2018-MOPC16

  26. L. Lai, F. Chen, J. Chen et al., Upgrade of digital BPM processor at DCLS and SXFEL. Proc. of IPAC2018, Vancouver, BC, Canada (JACoW, Vancouver, BC, Canada, 2018, pp. 4807-4810). https://doi.org/10.18429/JACoW-IPAC2018-THPML071

  27. L.W. Lai, Y.B. Leng, Y.B. Yan et al., Development and application of digital beam position measurement processor for FEL. Nucl. Tech, 41(7), 070402(2018). https://doi.org/10.11889/j.0253-3219.2018.hjs.41.070402(in Chinese)

  28. J. Chen, S. Cao, Y. Leng et al., Study of the optimal amplitude extraction algorithm for cavity BPM. Nucl. Instrum. Meth. A 1012, 165627 (2021). https://doi.org/10.1016/j.nima.2021.165627

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Contributions

All authors contributed to the study conception and design. Material preparation, data collection and analysis were performed by Jian Chen, Yong-Bin Leng, Lu-Yang Yu, Long-Wei Lai and Ren-Xian Yuan. The first draft of the manuscript was written by Jian Chen and all authors commented on previous versions of the manuscript. All authors read and approved the final manuscript.

Corresponding author

Correspondence to Jian Chen.

Additional information

This work was supported by the National Key Research and Development Program of China (No. 2016YFA0401903), National Natural Science Foundation of China (No. 12175293) and the Young and Middle-Aged Leading Scientists, Engineers and Innovators through the Ten Thousand Talent Program.

Rights and permissions

Springer Nature or its licensor holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Chen, J., Leng, YB., Yu, LY. et al. Optimization of the cavity beam-position monitor system for the Shanghai soft X-ray free-electron laser user facility. NUCL SCI TECH 33, 124 (2022). https://doi.org/10.1007/s41365-022-01117-8

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1007/s41365-022-01117-8

Keywords

Navigation