Abstract
This paper presents a novel liquid level control of a coupled two tank SISO system. Physical system is modeled from the open loop experimental response in two stages. A cascade control strategy is adopted. Fractional Order Proportional Integral (FOPI) and Fractional Order Proportional Derivative (FOPD) controllers are designed for the outer and inner loop, respectively, using frequency domain method. Similarly, conventional Integer Order Proportional Integral and Integer Order Proportional Derivative controllers are also designed to compare the performances. Reference signal tracking performance is tested with multiple step, ramp and sinusoidal reference signals. Ability of disturbance rejection is tested by adding more water into the tanks through a disturbance input channel. Experimental results reveal that the proposed FOPI–FOPD control scheme outperforms its integer order counterparts both in terms of reference signal tracking and disturbance rejection.
Similar content being viewed by others
References
Almutairi, N., & Zribi, M. (2006). Sliding mode control of coupled tanks. Mechatronics, 16(1), 427–441.
Bouarroudj, N., Boukhetala, D., & Boudjema, F. (2015). A hybrid fuzzy fractional order pid sliding-mode controller design using pso algorithm for interconnected nonlinear systems. Journal of Control Engineering and Applied Informatics, 17, 41–51.
Das, S. (2011). Functional fractional calculus (2nd ed.). Berlin, Heidelberg: Springer.
Delavari, H., Ghaderi, R., Ranjbar, A., & Momani, S. (2010). Fuzzy fractional order sliding mode controller for nonlinear systems. Communications in Nonlinear Science and Numerical Simulation, 15, 963–978.
Feedback-Instruments (2011). Coupled Tanks Control Experiments Manual Model No 33-041S, Feedback Instruments Ltd. UK.
Gouta, H., Said, S., Barhoumi, N., & Sahli, F. M. (2015). Observer-based backstepping controller for a state-coupled two-tank system. IETE Journal of Research, 61, 1–10.
Khan, M. K., & Spurgeon, S. K. (2006). Robust mimo water level control in interconnected twin-tanks using second order sliding mode control. Control Engineering Practice, 14, 375–386.
Luo, Y., Chen, Y., Wang, C., & Pi, Y. (2010). Tuning fractional order proportional integral controllers for fractional order systems. Journal of Process Control, 10, 823–831.
Machadoa, J., Kiryakova, V., & Mainardi, F. (2011). Recent history of fractional calculus. Communications in Nonlinear Science and Numerical Simulation, 16, 1140–1153.
Merrikh-Bayat, F. (2012). Rules for selecting the parameters of oustaloup recursive approximation for the simulation of linear feedback systems containing \(pi^{\lambda }d^{\mu }\) controller. Communications in Nonlinear Science and Numerical Simulation, 17, 1852–1861.
Monje, C., Chen, Y., Vinagre, B., Xue, D., & Feliu, V. (2010). Fractional-order systems and controls: Fundamentals and applications. London, UK: Springer.
Ogata, K. (2002). Modern control engineering (4th ed.). Prentice Hall, NJ: Pearson Education International.
Oldham, K. B., & Spanier, J. (1974). The fractional calculus: Theory and application of differentiation and integration to arbitrary order., Mathematics in science and engineering New York: Academic press.
Oustaloup, A., Levron, F., Mathieu, B., & Nanot, F. (2000). Frequency-band complex noninteger differentiator: Characterization and synthesis. IEEE Transactions on Circuits and Systems I: Fundamental Theory and Applications, 47, 25–39.
Pan, H., Wong, H., Kapila, V., & Zribi, M. (2005). Experimental validation of a nonlinear backstepping liquid level controller for a state coupled two tank system. Control Engineering Practice, 13, 27–40.
Podlubny, I. (1999). Fractional-order systems and pi\(^\lambda \) d\(^\mu \) controllers. IEEE Transactions on Automatic Control, 44, 208–214.
Poulsen, N., Kouvaritakis, B., & Cannon, M. (2001). Constrained predictive control and its application to a coupled-tanks apparatus. International Journal of Control, 74, 552–564.
Roy, P., Kar, B., & Roy, B. K. (2017). Fractional order PI-PD control of liquid level in coupled two tank system and its experimental validation. Asian Journal of Control, 19(5), 1–11.
Roy, P., & Roy, B. K. (2016). Fractional order PI control applied to level control in coupled two tank MIMO system with experimental validation. Control Engineering Practice, 48, 119–135.
Vijayalakshmi, S., Manamalli, D., & PalaniKumar, G. (2014). Closed loop experimental validation of linear parameter varying model with adaptive pi controller for conical tank system. Journal of Control Engineering and Applied Informatics, 16, 12–19.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kar, B., Roy, P. A Comparative Study Between Cascaded FOPI–FOPD and IOPI–IOPD Controllers Applied to a Level Control Problem in a Coupled Tank System. J Control Autom Electr Syst 29, 340–349 (2018). https://doi.org/10.1007/s40313-018-0373-z
Received:
Revised:
Accepted:
Published:
Issue Date: