Introduction

In the last century, it has become clear worldwide the key role that energy plays in human life [1, 2]: It is at the base of our modern life and economy. Currently, the growing attention significance to environmental issues has stimulated countries to exploit renewable energy resources and to encourage their use [36]. Among them, solar photovoltaic (PV) energy is considered one of the leading potential sources of electricity for the twenty-first century [711]: It utilizes an abundant energy source (the sun), has no emissions, can be easily integrated in buildings, and the cost of the installed kWp is decreasing and becoming more and more affordable with payback periods shorter and shorter. In fact, in the recent years, the generation of solar electricity from PV systems has penetrated the energy market in those countries where clear and stable policy for subsidies have been made.

The rapid growth of the solar industry has expanded the importance of PV system design and application for more reliable and efficient operation [12, 13]. The design of PV systems in an economically optimal way [1416] is usually done through detailed computer simulations [17, 18]: Transient analysis is useful when the different energy phenomena that take place in the heart of the production systems [19] should be accounted for, e.g., if they present some kind of solar tracking [20].

In performing such an analysis, the accurate evaluation of the operating temperature of the PV device (either a simple module or a PV/thermal collector of a building-integrated PV array) is of paramount importance [21], because several performance parameters of the PV system depend on it through the so-called temperature coefficients [22]. The derivatives can be determined for short-circuit current (Isc), maximum power current (Imp), open-circuit voltage (Voc), maximum power voltage (Vmp), and maximum power (Pmp), as well as fill factor (FF) and, finally, efficiency (η). Particular attention is focused on the energy conversion factor of a PV system that is commonly described by the electrical efficiency η [23] defined as the ratio of the electricity generated to the global solar irradiation impinging on the collector’ surface. Furthermore, the temperature coefficients for PV systems are directly related to the temperature coefficients for their individual cells, and thus, the so-called cell temperature Tc is the real key parameter to be identified because it affects, directly or indirectly, the energy conversion efficiency [24] of any PV system. In addition, it plays an important role in PV system design and sizing, since often the worst case operating conditions dictate the array size.

More physical insights into the dependence of the electric energy conversion mechanisms on the cell temperature can be obtained looking at the solid state physics of the cell [2527]: The energy bandgap of semiconductors, and consequently the quantum conversion efficiency, tends to decrease as the temperature increases [24, 28] due to the fact that the interatomic spacing increases when the amplitude of the atomic vibrations increases as a consequence of the increased thermal energy. An increased interatomic spacing decreases the potential seen by the electrons in the material, which in turn reduces the size of the energy bandgap (a direct increase/decrease in the interatomic distance, and consequently, bandgap, can be obtained also by applying high compressive/tensile stress [29, 30]).

Despite its great importance, the cell temperature Tc depends on such a lot parameters and weather variables that its correct evaluation is the critical point of any methodology aimed at properly sizing PV systems. A scan of the relevant literature [31, 32] easily produces an impressive number of correlations expressing the cell temperature as a function of the pertinent weather variables, namely, ambient temperature, local wind speed as well as the solar irradiance on the surface of PV systems, which are tilted toward the sun to maximize the amount of the incident solar radiation [25, 26, 33]. Radiation data, such as hourly direct and diffuse irradiance on the tilted surface, were usually required but smaller time steps could be necessary when load profiles vary with smaller time constants. However, meteorological stations and national or international standards often provide only daily global irradiation data on horizontal surface (sometimes they measure also the diffuse component), which are commonly summarized in monthly average values [3436].

In this framework, the objective of the present paper is a task of great practical importance from an engineering point of view: We want to define a methodology for estimating the operating cell temperature Tc starting only from the monthly mean value of the daily global irradiation on a horizontal surface. The methodology consists of a chain of models that are well-established in literature and that we apply in a step-by-step procedure to derive the cell temperature from the solar radiation data. In particular, we compare several models, focusing on how to couple them in order to obtain the best accuracy in the predicted data; finally, we investigate the suitability and the accuracy of the proposed methodology. In addition, we provide two new models for calculating the solar irradiance and the ambient temperature profiles. Comparisons with data measured in Rome confirm the applicability of the proposed approach and give information about the accuracy of the model.

The paper is organized as follows. In “Theory and models” section, the proposed procedure is illustrated: Subsection “Irradiance model” analyzes the radiation models used to predict the irradiance profiles on a tilted surface from the monthly average daily global irradiations on a horizontal surface; the models used to predict the PV cell temperature from the irradiance profiles are described in Subsection "Operating temperature of the photovoltaic cell.” Section “Results and discussion” presents the relevant results: The measurement setup is described in Subsection “Setup,” while in Subsection “Assessment of the models” a statistical analysis is performed on the results in order to assess the validity of the whole procedure, identifying and discussing the most accurate models. Finally, the main conclusions of the work are drawn.

Theory and models

The goal of the procedure described in the following subsections is to estimate the transient temperature of the photovoltaic cell during the day nd of the year, placed on a surface ST tilted γt with respect to the horizontal plane and rotated αt with respect to the north–south direction, starting from the monthly average daily global irradiation value H ¯ on a horizontal surface (the configuration is illustrated in Fig. 1). The procedure consists of five steps that are applied one after another in succession as shown in Fig. 2. Each step is based on the application of well-established models that are compared and discussed in order to obtain an accurate and robust procedure.

Fig. 1
figure 1

Geometrical configuration of the PV cell placed on a surface ST tilted γt from the horizontal plane and rotated αt from the north–south direction

Fig. 2
figure 2

Steps of the proposed procedure

Irradiance model

As is well-known, the quantity of solar radiation reaching the Earth’s surface during a day is governed by several factors: the solar elevation at noon, the duration of the day, the turbidity of the air, the total amount of water vapor in the air, and the type and amount of clouds [37]. When a direct measurement is not available, as often happens, H is taken as the monthly mean value H ¯ referred to the “average day” of the month, i.e., the day when the solar declination δ is equal to the average value of the month [33, 26]. The monthly average daily irradiation can be obtained from national standards or measurement campaigns or trough an Angstrom-type regression equation that relates the ratio between monthly average daily global irradiation and monthly average daily extraterrestrial irradiation at a particular location to the average fraction of possible sunshine hours [38].

From H ¯ , the global hourly irradiation Hh on a horizontal surface during the day nd of the month has to be somehow evaluated in order to compute the hourly global irradiation GTh incident on ST (for all the details see [33]), as

G Th = B Th + D Th + R Th ,
(1)

where the direct BTh, sky-diffuse DTh, and ground reflected (albedo) RTh components are given by

B Th = B h r b = 1 - k d r b H h
(2a)
D Th = D h r d = k d r d H h
(2b)
R Th = ρ 1 - cos γ t 2 H h .
(2c)

In Eq. (2) Bh,  Dh, and Hh = Bh + Dh are, respectively, the direct, diffuse, and global hourly irradiation on a horizontal surface, r b = cos θ / cos θ z is the beam radiation factor, with θ the solar incidence angle on ST, and θz the zenith angle of the Sun [33, chap. 1], kd is the cloudiness index, rd = DTh/Dh is the conversion factor for the hourly diffuse irradiation, and ρ is the ground reflectivity. It is assumed that the ground has very low reflectance, i.e., the reflected component is much lower than the sum of the direct and diffuse irradiation, so that an isotropic model may be used for the computation of the ground albedo. The relevant parameters in Eq. (2), i.e., Hh,  kd and rd, are evaluated as described in the following Subsections “Horizontal hourly global irradiation values,” "Hourly diffuse and direct irradiation,” and “Hourly diffuse irradiation on a tilted surface,” respectively.

Once the hourly global irradiation GTh is known, the irradiance profile IgT(t) on the tilted surface is finally computed as reported in Subsection “Solar irradiance profiles”.

Horizontal hourly global irradiation values

Several well-established methods have been proposed in literature to convert the average daily horizontal global irradiation H into horizontal hourly global values Hh. Most of them assume the day is symmetric, i.e., with same irradiation values for hours situated symmetrically with respect to the solar noon [3941], while a few of them try to account for the asymmetries between morning and afternoon [42, 43]. The characterization of a general distribution of hourly solar irradiation is made difficult by the non-stationary nature of the solar irradiation, which is affected by an unpredictable noise due to a variety of factors. Recently, sophisticated methods have been proposed, such as neural networks and autoregressive average models [44, 45]. Though all these methods are reliable and show good accuracy, they make the formulation more difficult to be implemented, so that the simple but effective correlation model presented in [41] is used. The correlation has been confirmed to be compatible with results obtained for Canada, India, Israel, and, lastly, Corsica [46] and to work best for clear days, when solar processes produce most of the output. According to this model, the hourly values Hh are computed as:

H h = r t H ¯ ,
(3)

where the ratio rt is given by

r t = 1 2 a + b cos ω 2 + ω 1 2 · sin ω 2 - sin ω 1 - π ω 2 - ω 1 180 cos ω s sin ω s - π ω s 180 cos ω s
(4)

with

a = 0.4090 + 0.5016 sin ω s - 60
(5a)
b = 0.6609 - 0.4767 sin ω s - 60 .
(5b)

In (4), ω1 and ω2 are the hour angles at the beginning and end, respectively, of the hour in question ( ω = 15 12 - h , with h the solar time), and ωs is the sunset hour angle for the day equal to cos - 1 - tan δ tan ϕ , with ϕ latitude of the location and δ declination for the day, which can be computed by means of the Cooper’s or Spencer’s formulas [33, chap. 1].

In (3), the monthly mean value H ¯ of the global daily solar irradiation on a horizontal surface has been used and the coefficient rt accounts for the specific day nd of the month through the declination angle δ. The suitability and accuracy of (3) in the framework of the whole proposed methodology has been assessed in Section “Results and discussion.”

Hourly diffuse and direct irradiation

Since the pioneer work of Liu and Jordan [39] in the early 1960s, several models have been proposed in literature to evaluate the hourly average cloudiness index kd = Dh/Hh, where Dh is the hourly sky-diffuse irradiation on a horizontal surface. A complete list of these models is beyond the scope of the present paper; comparative studies among the most frequently used correlations can be found in [4749]. These correlations are usually expressed in terms of first- to fourth-degree polynomials relating the diffuse fraction kd with the hourly clearness index kt = Hh/H0h, defined as the ratio of the hourly global solar irradiation Hh and the hourly extraterrestrial solar irradiation on a horizontal surface H0h [33, chap. 1].

In the present work, we have compared the four models from Karatasou [50], Erbs [51], Miguel [52], and Reindl [53] against experimental irradiation values for the Italian location of Rome over a period of 2 years.

Karatasou [50] model is a third-order polynomial correlation based on data from one location at Athens (Greece):

k d = 0.9995 - 0.05 k t - 2.415 k t 2 + 1.4926 k t 3 k t 0.78 k d = 0.20 k t > 0.78 .
(6)

Erbs [51] model is a fourth-order polynomial correlation based on data from four locations in USA:

k d = 0.9996 - 0.09 k t k t 0.22 k d = 0.951 - 0.1604 k t + 4.388 k t 2 - 16.638 k t 3 + 12.336 k t 4 0.22 < k t 0.80 k d = 0.1652 k t > 0.80 .
(7)

Miguel [52] model yields a third-order polynomial for kd using a data set from several sites in the north Mediterranean Belt (e.g., France, Greece, Italy, Portugal, and Spain):

k d = 0.9943 - 0.081 k t k t 0.21 k d = 0.724 + 2.734 k t - 8.32 k t 2 + 4.967 k t 3 0.21 < k t 0.76 k d = 0.1766 k t > 0.76 .
(8)

Finally, Reindl [53] established a very simple correlation, studying the influence of climatic and geometric variables on the hourly diffuse fraction based on data measured at five European and US locations:

k d = 1.0234 - 0.248 k t k t 0.30 k d = 1.45 - 1.67 k t 0.3 < k t 0.78 k d = 0.1474 k t 0.78 .
(9)

A comparative analysis of the predictions of the four models based on consolidated standard statistical parameters [54] reported in Section “Results and discussion,” has showed that the physically based method proposed by Miguel correlates better with the data collected in Rome.

Once the hourly diffuse irradiation component Dh is known, the hourly direct irradiation Bh is then computed as Bh = Hh − Dh.

Hourly diffuse irradiation on a tilted surface

The conversion of the hourly horizontal diffuse irradiation Dh to hourly diffuse irradiation DTh on the tilted surface ST can be expressed as

D Th = r d D h ,
(10)

where rd is the conversion factor.

The methods proposed in literature for the evaluation of rd are classified into isotropic or anisotropic models. The isotopic models assume that the sky dome irradiates uniformly so that the diffuse radiation incident on the tilted surface depends on the fraction of the sky dome seen by it. The anisotropic models try to model the anisotropy of the diffuse radiation, decomposing it in different components, i.e., the circumsolar component (Sun’s aureole), the brightness of the horizon, and the isotropic component of the sky dome. Validation studies and testing of several well-established models to predict rd have been performed in [5557]. However, results are not always in agreement, and ranking these models according to their accuracy is not simple. In fact, their abilities to predict the diffuse radiation on a tilted surface are a priori function of the atmospheric conditions (clear, partially cloudy, or overcast sky), since they take assumptions about the isotropy or anisotropy of the sky dome. The way in which the anisotropy is accounted for makes them strongly dependent on the surface orientation (it has been observed that all models produce large errors for east–west-facing PV surfaces [55]). In addition, several models are based on empirical data obtained for some particular geographical locations, so that they show enhanced/poor accuracy when used in locations with similar/different irradiation conditions. Anyway, the use of well-known statistical indicators [54], and much more complex statistical analyses [56] performed on data collected from several locations in the world, have generally, but not always, indicated that the Ma-Iqbal [58], Reindl [59], Muneer [60], and Perez [61, 62] models are those that give the most accurate predictions for small azimuthal angle αt (i.e., south-facing surfaces). In addition, in [56] it was found that the Ma-Iqbal model performs best under all sky conditions, clear and partially cloudily, whereas the Muneer model gives the best results for cloudy-sky conditions.

In this framework, we have selected these four models and compared their predictions against experimental irradiation values, as reported in Section “Results and discussion.”

In the model proposed by Ma-Iqbal [58], the diffuse irradiance on an inclined plane is considered to be the addition of the circumsolar component coming from the direction near the solar disk and a diffuse component isotropically distributed from the rest of the sky. These two components are weighted according to an index of anisotropy that represents the transmittance through the atmosphere of direct irradiance. Unlike the original model of Hay [63] who defined his own sky-clarity factor F = Bh/H0h, Ma and Iqbal used the clearness index kt as index of anisotropy. According to the Ma-Iqbal model, the conversion factor rd can be computed as

r d = k t r b + 1 - k t 1 + cos γ t 2 .
(11)

The Reindl model [59] assumes linearity of the isotropic and circumsolar contributions to the diffuse radiation on a tilted plane according to the Hay model and adopts the same correction factor that takes into account the brightness of the sky near the horizon used in the Temps-Coulson model [64]. The conversion factor rd is determined as:

r d = F r b + 1 - F 1 + cos γ t 2 1 + B h H h sin 3 γ t 2 ,
(12)

where F = Bh/H0h is the Hay’s sky-clarity factor.

Muneer [60], partially following the model proposed by Gueymard [65], considers that the irradiance can be expressed as a linear combination of values between fully covered sky and cloudless sky which in turn is the addition of the circumsolar component and a hemispheric factor. The conversion factor rd is expressed as:

r d = T M 1 - F M + F M r b ,
(13)

where TM is the Muneer’s tilt factor defined as the ratio between the slope background diffuse radiation and the horizontal diffuse radiation given by

T M = 1 + cos γ t 2 - 2 B 3 + 2 B γ t cos γ t - sin γ t π + 1 - cos γ t 2 ,
(14)

and FM is a composite anisotropic index, equal to Hay’s sky-clarity factor F for non-overcast conditions and 0 for overcast sky. In Eq. (14), B is the radiation distribution index whose values depend on the particular sky and azimuthal conditions, and the location: for southern European locations, Muneer recommends the following correlation

2 B 3 + 2 B = π 0.00263 - 0.712 F - 0.688 F 2 .
(15)

The Perez model is more computationally cumbersome than the others because it represents the isotropic diffuse, circumsolar, and horizon brightening components with more details using empirically derived coefficients. Yet, the model developed by Perez in [62] is considerably simpler, and more accurate, than the original model proposed in his first work [61]. In fact, the conversion factor rd is computed as

r d = 1 - F 1 cos 2 γ t 2 + r b F 1 + F 2 sin γ t .
(16)

where F1 and F2 are, respectively, the circumsolar and horizon brightness coefficients

F 1 = max 0 , f 11 + f 12 Δ + π θ z 180 f 13
(17a)
F 2 = f 21 + f 22 Δ + π θ z 180 f 23 ,
(17b)

whereθz is the beam radiation factor, Δ = k d k t is the brightness parameter and fij are tabulated statistically derived coefficients [62] depending on the clearness parameter

ε = 1 1 + 5.535 · 10 - 6 θ z 3 D h + B h cos θ z D h + 5.535 · 10 - 6 θ z 3 .
(18)

In Eq. (16), rb is the modified beam radiation conversion factor defined as

r b = max 0 , cos θ max cos 85 , cos θ z .
(19)

Solar irradiance profiles

The transient simulation of the temperature of photovoltaic modules requires the knowledge of continuous profiles versus time t of the global solar irradiance IgT on the tilted surface during the day nd. Starting from the hourly mean values of the global irradiation GTh, various studies consider that the solar irradiance is distributed over the time with a constant repartition which, however, has been demonstrated to be an unrealistic hypothesis, since this assumption does not provide a precise idea of the different transient energy phenomena that take place in the heart of the solar system. In [17], it was proposed a linear model that allows the determination of irradiance data, averaged on small time step Δ t (e.g., one minute), from hourly irradiation values. Starting from this work, a second order model is here proposed.

The solar irradiance I j (t), on the tilted surface, is assumed to vary in a quadratic manner between the beginning time hj−1 and the ending time h j of the j-th hour of the day (e.g., the first hour begins at time t equal to h0 = 00:00 and ends at time h1 = 01:00), i.e.,

I j = a j t 2 + b j t + c j ,
(20)

with j = 1 , 2 24 and h0 = 0, h1 = 1, h24 = 24. It is evident that it is necessary to enforce three equations for every hour occurring between sunrise hSR and sunset hSS times since the number of unknowns for every hourly profile is equal to three. As shown in Fig. 3a, if sunrise or sunset does not occur in the j-th hour, the three conditions to be enforced are as follows:

  • the integration of the irradiance I j (t) over the hour must be equal to the hourly irradiation H j (on tilted or horizontal surface),

    h j - 1 h j I j ( t ) d t = H j ;
    (21)
  • the profiles I j (t) and Ij+1(t) and their first derivatives at every time h j between two successive hours must be continuous

    a j h j 2 + b j h j + c j = a j + 1 h j 2 + b j + 1 h j + c j + 1
    (22a)
    2 a j h j + b j h j = 2 a j + 1 h j + b j + 1 h j .
    (22b)
Fig. 3
figure 3

Illustration of the quadratic model for approximating the solar irradiance profile from hourly mean values of the global irradiation: a daylight hours; b hour when sunrise takes place

If sunrise or sunset occur in the considered j-th hour (Fig. 3b), Eq. (21) must be modified according to

h SR h j I j ( t ) d t = H j
(23a)
h j - 1 h SS I j ( t ) d t = H j ,
(23b)

because the model considers that the solar irradiance has been spread over the hour whereas it just took place since sunrise or until sunset

Then, in the hour when sunrise (or sunset) takes place, the value of the irradiance profile at hSR (or hSS) must be set equal to zero, i.e., I j t h SR = 0 (or I j t h SS = 0 ).

Operating temperature of the photovoltaic cell

The cell operating temperature Tc is the proper temperature to use in order to predict the electrical performance of the PV module. Because of the internal processes that take place within the cells during their exposure to sun, a large portion of the incident irradiance is degraded and released as heat. Standard heat transfer mechanisms must be accounted for to compute the appropriate energy balance on the cell/module leading to the prediction of Tc. At steady-state conditions, only convection and radiation mechanisms are usually considered, since they are prevalent on the conduction mechanism that merely transports heat toward the surfaces of the mounting frame (especially in the case of rack-mounting free-standing arrays). A survey of the explicit and implicit correlations proposed in literature linking Tc with standard weather variables and material and system-dependent properties can be found in [32].

In the present work, we compare four different explicit equations against experimental data. Among the large number of correlations proposed in literature, we have chosen the equations whose application appears to be the best and simplest. Hence, we have chosen equations that are explicit, depend on easily measurable parameters and, are of wide applicability. The four alternative correlations are [31, 32, 66, 67]

T c = T a + I gT I NOCT T NOCT - T a , NOCT
(24a)
T c = T a + 0.32 8.91 + 2.0 v w I gT
(24b)
T c = 0.943 T a + 0.028 I gT - 1.528 v w + 4.3
(24c)
T c = T a + 0.0138 I gT 1 + 0.031 T a 1 - 0.042 v w
(24d)

where TNOCT is the so-called nominal operating cell temperature (the temperature TNOCT is defined as the temperature of the cell at the conditions of the nominal terrestrial environment (NTE): Solar irradiance INOCT = 800 W/m2, ambient temperature Ta, NOCT = 20 °C, average wind speed 1 m/s, nil electrical load, and free-standing mounting frame oriented normal to solar noon), Ta is the ambient temperature and vw is the wind speed (free stream wind speed in the windward side of the PV array).

Two remarks are necessary before applying the previous expressions. The cell temperature Tc may be higher than the back-side temperature Tb, which is the directly measured quantity, of a few degrees, being this difference dependent mainly on the module substrate material and the intensity of the solar irradiance IgT(t). The two temperatures are related through the simple linear expression [68]

T c = T b + I gT I ref Δ T ref ,
(25)

where Iref is the reference solar irradiance of 1,000 W/m2 and Δ T ref is the temperature difference under this reference solar irradiance. This temperature difference is typically ranging between 2 and 3 °C for flat-plate modules in an open-rack setting [68].

The evaluation of Tc requires an accurate estimation of the ambient temperature. Assuming it constant during the day and equal to the average value is an unrealistic assumption. Here the following third-order approximation for a smooth transient from the minimum Tmin to the maximum Tmax temperatures registered during the day is assumed

T a ( t ) = 1 h SR - h SS 3 ( h SS - t ) 2 ( h SR - 3 h SS + 2 t ) T max + ( 3 h SR - h SS - 2 t ) ( h SS - t ) 2 T min .
(26)

It has been observed that the approximation (26) provides accurate agreement with the measured results during the hours from sunrise to sunset, when the PV system produces energy.

Results and discussion

The ability of the proposed procedure to predict the PV cell temperature is tested comparing the predicted results with experimental values measured in Rome during the two years 2010 and 2011. The four models selected for the computation of the cloudiness index kd in Subsection “Hourly diffuse and direct irradiation,” for the computation of the hourly diffuse irradiation on a tilted surface (i.e., the conversion factor rd) in Subsection “Hourly diffuse irradiation on a tilted surface,” and for the computation of the cell temperature Tc in Subsection “Operation temperature of the photovoltaic cell” are compared. Furthermore, we studied the best combination of these models in order to obtain the best accuracy of the predictions.

The accuracies have been assessed using well-known statistical indicators [54]: the mean bias error (MBE), the root mean square error (RMSE), and the coefficient of determination (R2). They are defined as:

MBE = 1 N i = 1 N x p , i - y m , i
(27a)
RMSE = 1 N i = 1 N x p , i - y m , i 2
(27b)
R 2 = ESS TSS = i = 1 N x p , i - y ¯ m 2 i = 1 N y m , i - y ¯ m 2 ,
(27c)

where N is the number of data points during each day, xpi and ymi are, respectively, the predicted and measured (observed) data points, y ¯ m = i = 1 N y m , i is the mean value of the measured data, ESS is the Explained Sum of Squares, and TSS is the Total Sum of Squares. The MBE determines whether the model underestimates or overestimates experimental data, the RMSE gives a measure of how well the model can predict the experimental data (it provides information on the short-term performance of the model by allowing a term-by-term comparison of the actual deviation between the estimated and the measured values), and R2 provides a measure of how well the model explains observed phenomena (its value shows how well future outcomes can be predicted by the model).

Setup

The irradiance and temperature data have been measured on the roof of the Department of Electrical Engineering, Faulty of Engineering, located in Rome, Italy (ϕ = 41°53′38′′N, λ = 12°29′37′′E) during the two years 2010 and 2011. As shown in Fig. 4a, the setup consists of 20 polycrystalline Si-modules mounted in free-standing manner, i.e., on racks placed above the roof. The modules are tilted γt = 30° from the horizontal surface and are south-facing (αt = 0°). The modules are subdivided in two strings, each formed by the series connection of 10 modules (the upper and lower ones) which have been left open-circuited during the temperature measurements. The manufacturer’s specifications give TNOCT = 48 ± 3 °C (fixed to 50 °C, in the following) and Δ T ref = 2 C (added to Tb which is the real measured quantity). Figure 4b shows the PT100 sensors (platinum resistance thermometers sensors) placed on the back of the PV module to measure the rear temperature Tb. Six sensors have been placed on three modules (two sensors per module) in order to investigate the uniformity of the temperature among different modules with the same exposition. An identical PT100 sensor has been used to measure the ambient temperature as shown in Fig. 4c. The Yokogawa DC100 data collector unit has been used to collect and register the data on seven independent channels. The solar irradiance data were acquired using class-1 pyranometer Delta-Ohm LP Pyra. The measurements have been performed with a real-time data-acquisition step of 30 sec (2880 data points for each channel per day). According to the Guide JCGM [69], the expanded uncertainty U T c with a coverage factor k = 2 (corresponding to a confidence level p = 95.45 %) is ±0.81 °C.

Fig. 4
figure 4

Test setup consisting of: a free-standing modules placed on the roof of the Electrical Engineering Department; b PT100 sensors used to measure the back temperature Tb of the modules; c PT100 sensor for the measurement of the ambient temperature Ta

The monthly average daily irradiation values used in the following computations are, {2.33, 3.28, 4.25, 5.29, 6.34, 6.74, 6.72, 5.87, 4.70, 3.61, 2.51, 2.12} kWh/(m2 day), provided by national standards for the twelve months of the year, respectively. The albedo factor has been set equal to 0.2 (dark-colored, rough soil surfaces). No particular shading affected the PV system output.

Assessment of the models

As explained in the previous Section, the correct modeling of the irradiance incident on the tilted surface of the PV module is required at the first step of the proposed procedure. Hence, it is mandatory to assess the accuracy of the selected models used for its prediction.

The diffuse and direct irradiation values on a horizontal surface predicted by the four models used for the computation of the cloudiness index kd (Subsection “Hourly diffuse and direct irradiation”) are reported in Figs. 5 and 6, respectively, where they are plotted against observed values. The modeled results have been computed considering in input of Eq. 3 the aforementioned monthly average daily irradiation values H ¯ h provided by national standards in order to compute the hourly values of the global irradiation on a horizontal surface and then decomposing these global values into diffuse and direct components. The figures also plot for each model the linear line of best fit (dotted line) as well as a line of one-to-one correlation (solid line) for comparison purposes. Table 1a, b presents the modeled statistics for the diffuse Dh and direct Bh irradiance estimates, respectively, in comparison with the experimental data. The results indicate that all the models provide an acceptable agreement. The level of uncertainty for all the models, represented by the RMSE in W/m2, varies between 25 and 50 W/m2 for diffuse irradiance (33–61  average value) and between 80 and 125 W/m2 for direct irradiance (27–43 % of the average value). With regard to model bias, the results indicate that the level and the direction of the bias, represented by the MBE in W/m2, vary among the four models. Results show that the Miguel model achieves the best match with the experimental data as indicated by the deviation of the line of best fit from the line of one-to-one correlation and as confirmed by the higher R2 values.

Fig. 5
figure 5

Experimental versus modeled hourly values of diffuse irradiation Dh on a horizontal surface for Rome, with a linear line of best fit (dotted line) and a line of one-to-one correlation (solid line)

Fig. 6
figure 6

Experimental versus modeled hourly values of direct irradiation Bh on a horizontal surface for Rome, with a linear line of best fit (dotted line) and a line of one-to-one correlation (solid line)

Table 1 Irradiation and temperature statistics for model estimates against measured data

The models for converting the hourly horizontal diffuse irradiation Dh to the hourly diffuse irradiation DTh on a tilted surface (“Hourly diffuse irradiation on a tilted surface”) are compared in Fig. 7 where the values predicted by the four selected models are reported along with the experimental data measured on the horizontal surface. The figure shows the predicted values of the global irradiance GTh on the tilted plane of the PV panels plotted against measured values. In addition, Table 1c presents the statistics for the global irradiance estimates. The results show that the Perez model gives the best estimate of the global irradiance on the tilted surface. The bias values (MBE) highlight that the four models exhibit a tendency to underestimate global irradiance values compared with the experimental data and that the four models achieve comparable values of R2. The uncertainty (RMSE) ranges between 80 and 125 W/m2.

Fig. 7
figure 7

Experimental versus modeled hourly values of global irradiation GTh on a tilted surface for Rome, with a linear line of best fit (dotted line) and a line of one-to-one correlation (solid line)

The results of the four cell temperature models reported in Eqs. (24a–d) are shown in Fig. 8. The modeled results have been computed every 15 min using the experimental global irradiation measured on the surface of the PV panels, using Eq. (26) to estimate the ambient temperature and setting the wind speed vw to the average value of the day (the weight of the wind speed in the used equations is not so high as to require a more accurate approximation). The results indicate that the third model provides the closer agreement with the measured results. The level of uncertainty for all the models varies between 4 and 8 °C (23–47% of the average value) while the bias level ranges between 0.8 and 2.3 °C. The bias direction is always negative, i.e., the models tend to underestimate the cell temperature. This is mainly due to several reasons: There are uncertainties in the TNOCT calculation; difficulties arise on the correct computation of the instantaneous wind velocity vw due to the fact that there are at least seven different definitions in use as explained in [31]; the operating temperature Tc itself shows some variations in the same module and among different modules. In fact, looking at Fig. 9, which shows the temperature profiles on August 21, 2010, temperature differences of around 5 °C can be observed depending on the thermocouple position. It should be underlined that the estimation of the Tc from the back temperature Tb with reasonable accuracy is here possible because the modules are standard crystalline ones. When modules are specially designed for some particular applications, extra care must be exercised. It should be observed that a heating of the module is observed during the afternoon–evening period: This makes differences between Tc and Ta higher in the afternoon than in the morning for the same values of irradiance.

Fig. 8
figure 8

Experimental versus modeled hourly values of cell temperature Tc for Rome, with a linear line of best fit (dotted line) and a line of one-to-one correlation (solid line)

Fig. 9
figure 9

Differences in module temperatures on August 21st measured by the six thermocouples

Figure 10 shows the comparison between the profiles of the ambient temperature Ta measured during two representative days and the profiles estimated through Eq. (26) starting from average historical temperature data (http://www.ilmeteo.it). It can be observed that the accuracy is reasonable; when the day is particularly clear and the irradiation is high (e.g., June 21) the measured profile rises a little faster than the predicted one. Yet, the differences remain always below 5 °C.

Fig. 10
figure 10

Comparison between the estimated ambient temperature profile and the measured data for two representative days

Model combination results

From the previous results, it was found that the Miguel model, the Perez model, and Eq. (24c) achieve the best estimates of, respectively, the diffuse irradiance on a horizontal surface, the diffuse irradiance on a tilted surface and the cell temperature. However, it is possible to observe, especially for the global irradiance on a tilted surface and the cell temperature, that none of the models consistently outrank the other ones. Hence, we have tried all the possible combinations of the models used for the estimation of the hourly horizontal diffuse (direct) irradiance, the hourly global irradiance on the titled surface and the cell temperature, in order to identify the best combination. Table 2 presents the statistical results for the comparison between the most significant values predicted by some combinations and the measured values for the cell temperature Tc. The statistics confirm that the combination of Miguel, Perez, and Eq. (24c) achieves the highest level of accuracy for the cell temperature.

Table 2 Temperature statistics for combination modeled estimates against measured data

Conclusions

The paper presents an exhaustive methodology for the estimation of the transient operating cell temperature of a PV system. The proposed procedure estimates the transient temperature of the photovoltaic cell during the day nd of the year, placed on a surface ST tilted γt from the horizontal plane and rotated αt from the north–south direction, starting from the monthly average daily global irradiation value H ¯ on a horizontal surface. The study is considered of high interest since the values of horizontal solar irradiation are often the only data provided by meteorological stations.

The procedure consists of five steps that are applied one after another in succession:

  • computation of the hourly global irradiation on a horizontal surface Hh;

  • computation of the hourly diffuse irradiation on a horizontal surface Dh;

  • computation of the hourly diffuse irradiation on a tilted surface DTh;

  • computation of the irradiance time profile I t ;

  • computation of the cell temperature Tc.

Several well-established models have been used at each step, and the accuracy of different combinations of these models has been investigated in comparison with data measured in Rome. In addition, two new models for calculating the solar irradiance and the ambient temperature profiles have been also provided.

An error analysis, based on well-known statistical indicators, i.e., mean bias error (MBE), root mean square error (RMSE), and the coefficient of determination (R2), reveals that the combination of Collares–Pereira, Miguel, Perez, proposed irradiation model, and Eq. (24c) achieves the highest level of model accuracy for the cell temperature. However, it has been observed that, especially as concern the global irradiance on a tilted surface and the cell temperature, none of the models consistently outrank the other ones.