Introduction

Tantalum (Ta) is one of the most important metallic biomaterials and often applied as film material to improve the performance of substrate because of its excellent biocompatibility and high corrosion resistance. The combination of physical and chemical properties of tantalum makes it a unique material for using in high temperature and advanced technological applications. Some exceptional properties of tantalum are high melting point, good heat and electrical conductivity, corrosion resistance and high ductility. Tantalum crucibles are used for high-temperature processes, like fusion, thin-film deposition, distillation, and as heat exchangers. In the electronic industry, tantalum is used for manufacturing of capacitors, coils and boats for resistive evaporation. In the recent years, thin films of tantalum are attractive in a number of applications, which include protective coatings for corrosion, and wear resistance [14] because of its very high melting point, toughness, and immunity to chemical attack. The inertness of Tantalum in contact with body fluids and tissues, and excellent his to-compatibility makes it useful in biomedical implants and orthopedics [5].

Today, the application of ion beam is considered as one of the effective approaches to improve the metal properties since ion implantation can change the surface morphology, which causes some microstructure defects and modifies the corrosion resistance [8]. Ion implantation using active gases are not so common to produce structure change and do some topographical and morphological changes and introduce chemical change on the surface of the sample [7, 8].

Wear control and corrosion were among the first applications observed because of the large economic burden they impose on society. A large number of survey experiments with some successes, some failures, and some contradictory results characterized early results. The basic framework for understanding corrosion phenomena is the mixed potential theory of corrosion [1]. Corrosion reactions in aqueous media are oxidation–reduction reactions in which the free energy change determines the feasibility of the reaction and iscontrolled by electrode kinetics. These reasons can be combined on electrode potential versus current density diagrams to describe corrosion reactions and their anodic and cathodic partial reactions. The use of ion bombardment to control corrosion includes modification of the surface composition to manipulate either the anodic or the cathodic reaction in a way, which reduces the corrosion current.

During the past 15 years, it has been observed that in addition to argon ion implantation, other ions, such as tantalum, chromium, boron and carbon, are needed to optimize the effects of ion implantation on the tribological and corrosive behavior of materials. In other words, ion implanters for surface modification of metals can be made a suitable substrate in different applications due to change of surface such as capacitors, resistors, and more recently as diffusion barriers in integrated circuits with copper interconnects [69], and polish stop in chemical mechanical polishing [10]. Other applications of Ta are in X-ray optics and in X-ray lithography as absorbers [11]. The ability to change metal surfaces with ion implantation has afforded the corrosion researcher a new flexibility in trying to recover the corrosion resistance of metals. At the Naval Research Laboratory, for example, there has been an extensive program aimed at improving corrosion resistance using the techniques of ion bombardment, ion beam mixing, and ion beam-assisted deposition, as well as laser surface processing and alloying [12].

It is well known that aqueous corrosion proceeds through the operation of microscopic coupled anodic and cathodic processes. Thus, ion implantation modification can be utilized so as to interfere with the corrosion process by (1) modification of the cathodic process or (2) modification of the anodic process Other approaches involve (3) use of corrosion-resistant coatings, and (4) improvement of the passive film [1317].

In this study, tantalum was applied as substrate for doing argon ion implantation in various doses to investigate the change of surface roughness, corrosion resistance, and the effects of corrosion on the surface by using atomic force microscopy and scanning electron microscopy.

Experimental details

Ion bombardment was carried out on tantalum samples with size of 1 cm × 1 cm and 1 mm thicknesses by the ion implantation facility, which was performed in Plasma Physics Research Center (PPRC), Science and Research Branch. Table 1 shows the chemical composition of the substrates, analyzed by Energy Dispersive X-ray (EDX). Fig. 1 shows the schematic of ion implantation system. Ion bombardment procedure is performed by argon ions (99.999%) with the energy of 30 keV and doses of 1 × 1017–10 × 1017 ions/cm2 at ambient temperature and the angle between the implanted ions and surface of samples is 90°. Before ion implantation, sample surfaces were polished to a glossy finish by diamond paste and then cleaned ultrasonically in alcohol and acetone bath and then dried in an oven at 100 °C. The extracted ions (without mass selection) are accelerated to the maximum energy of 30 keV. Ion beam energy and current densities are kept fixed for all the samples. The ion beam cross section was expected to cover all the sample area uniformly. A thermocouple is used to measure the sample temperature during the implantation. The implantation parameters are listed in Table 2. Before starting of ion implantation, the entire sample had room temperature. This temperature changed during implantation because of heat transfer from ion bombardment to the samples.

Table 1 Chemical composition of tantalum (wt%)—method EDX
Fig. 1
figure 1

Diagram of ion implantation system

Table 2 The process parameters during implantation

The structural properties and composition of the tantalum samples are investigated with different methods. The implantation-induced modification of surface roughness is studied employing an atomic force microscopy (AFM). SPM Auto Probe CP, Park Scientific Instruments to investigate the morphology and roughness of the surface, performed atomic force microscopy (AFM). AFM was carried out in a non-contact mode and in the scanning area of 1 µm2 with a low stress tip of less than 20 nm radius. In order to studythe topography and roughness of the surface, AFM analysis in contact mode and scanning area of 1 µm2 were used. Electrochemical corrosion studies of the modified surfaces are done by potentiodynamic method. For these tests a potentionstat model EG&G applied Princeton 273A is used. The corrosion solution was 0.5 molar H2SO4. The potential was measured by saturated calomel electrode (SCE) as a reference electrode, scanned from −700 mV versus open circuit potential (OCP) up to approximately +1500 mV versus OCP at the scan rate of 1 mV/sec. The ends of the scans were selected after considering trans passive behavior in polarization curves. The corrosion potential (Ecorr) and corrosion current density (icorr) were extracted from potentiodynamic curves with the linear polarization method using corer view software. Surface of the tantalum samples was analyzed by scanning electron microscopy (SEM), with a Sirius SD devise equipped with an energy dispersive X-ray (EDX) analyzer. The average concentration of elements from a plan view of the SEM image with the lowest magnification (×100) wear was estimated by EDX analysis.

Result and discussion

Surface morphology study by AFM

Figure 2 shows the atomic force microscopy (AFM) images of a 1000 nm × 1000 nm scan area of the un-implanted samples of (a); the implanted one with argon ion doses of 1 × 1017(b); 5 × 1017 (c); 7 × 1018 ions/cm2 (d); and 1 × 1018 ions/cm2 (e). As shown in Fig. 2b–e, surface texture by ion implantation was directly observed with atomic force microscopy (AFM). There was significant change in areas such as roughness, grain size, its distribution for the un-implanted sample, and samples implanted with argon ions. Surface roughness of the samples underwent a substantial change after bombardment. Figure 3 shows the AFM results through a roughness variation curve. As seen in Fig. 3, Table 3 shows the variation of average and root mean square roughness on tantalum. Surface roughness of tantalum increased up to 5 × 1017 ions/cm2 dose and then decreased for the 10 × 1017 ions/cm2 dose.

Fig. 2
figure 2

Three-dimensional AFM images of sample surfaces a unimplanted, b dose 1 × 1017 ions/cm2, c dose 5 × 1017 ions/cm2, d dose 7 × 1017 ions/cm2, e dose 10 × 1017 ions/cm2

Fig. 3
figure 3

Roughness variation of tantalum surface to argon ion implantation increase

Table 3 variation of average roughness and root mean square roughness

The former can be explained by the sputtering effect due to the ion bombardment, while the latter may be related to the redistribution of material into valleys by eroding surface roughness peaks and ion bombardment enhancing the surface diffusion mechanism, which occurs at high doses [7]. Another justification for roughness increase in the dose 5 × 1017 ions/cm2 is an increase in surface diffusion of tantalum atoms in the sample surface [8]. It can be clearly seen that the sample surface roughness undergoes a substantial change after bombardment. In the case of unimplanted (Fig. 2) there is a smooth surface whose surface morphology contained many small hillocks, and the root mean-square roughness of the surface has been further measured.

The results of surface roughness, obtained by AFM analysis are given in Table 3. The initial value of 22.3 Å of the sample before implantation by argon ion implantation on the tantalum with a dose of 1 × 1017 ions/cm2 increased, and since the formation of a comparatively small grain was also observed, the value of surface roughness decreased to 7.25 Å in doses of 10 × 1017 ions/cm2. As shown, the surface roughness has risen by increasing the dose of ion implantation from 1 × 1017 to 5 × 1017 ions/cm2, which implies that increasing the dose and rate of deposition leads to larger grain formation on the surface according to incorporation and the integration process.

The increasing surface roughness was confirmed by AFM images’ analyses, which exposed the construction of tracks or pathways on the surface. However, by rising the dose to 7 × 1017 and 10 × 1017 ions/cm2, almost all pathways and pits were filled uniformly since the surface was bombarded by a constant ion flux and a sufficient dose for deposition. Like the AFM, images revealed the composition of a uniform surface with same dimension grains, and the roughness has been significantly decreased. Therefore, the implanted sample with 10 × 107 ions/cm2 showed the least value compared with other samples, and the amount of energy in this dose makes the grain composition constant.

Corrosion test

Figure 4 shows the potentiodynamic findings by electrochemical analysis in the implanted and unimplanted samples in different doses. According to Figs. 5 and 6, the corrosion current and potential are, respectively, recognized as corrosion resistance in all implanted samples. The corrosion current has minimum value in implanted samples compared to the unimplanted ones.

Fig. 4
figure 4

Polarization curves of unimplanted and implanted tantalum samples

Fig. 5
figure 5

Corrosion current densities variation because of the ion implanted in the different doses

Fig. 6
figure 6

Corrosion potential variations because of ion implantation in different doses

Figure 5 shows the differences of corrosion current density (icorr) of the implanted tantalum samples in terms of argon implantation doses. This curve shows that the maximum and minimum corrosion current density happens at samples implanted with doses of 5 × 1017 and 10 × 1017 ions/cm2, respectively. In the meantime, no substantial variation in passivation current has been observed even though the corrosion potential increased significantly. As can be observed, corrosion current density (icorr) decreases initially at 5 × 1017 ions/cm2 and then increases. Figure 6 shows the values of the corrosion potential for unimplanted and implanted samples. In addition, it shows that argon ion implantation in tantalum increases the corrosion potential of the implanted samples at doses of 1 × 1017 ions/cm2. This tendency continues up to the 5 × 1017 ions/cm2 dose, but at the dose of 7 × 1017 ions/cm2, the corrosion potential slightly decreases. Moreover, corrosion potential in implanted samples exposed maximum value to the unimplanted samples. According to the AFM images, the reason of these reverse findings can be explained by inadequate ion energy bombardment on the surface concerning the formation of cracks and pores in grain bounders. Therefore, increasing the roughness of the surface in grain boundaries increases the tendency to corrosion compared to other conditions. Furthermore, based on the obtained findings with corrosion, current and potential curve, all implanted samples exposed suitable performance for corrosion, which implies that the surface corrosion resistance has improved by argon ion implantation.

Scanning electron microscopy (SEM)

Scanning electron microscopy (SEM) images of samples were applied to show the formation of thick corrosion products on a sample surface implanted by various argon doses (Fig. 7). The creation of the corrosion products can be observed on the surface of the sample with 1 × 1017 ions/cm2 dose (Fig. 7b). Argon doses in ion beam processes at 1 × 1017 ions/cm2 can not only create a protective layer, but also damage the surface of the tantalum due to the high collision rate of ions with the surface tantalum. In a dose of 1 × 1017 ions/cm2, surface defects increase substantially and, therefore, corrosion rate increases accordingly. Corrosion rate decreases by the increase of dose at 5 × 1017 ions/cm2, but local pitting corrosion is clearly observed on the surfaces of the samples (Fig. 7c). Maximum effect of corrosion occurred in the implanted sample with a dose of 7 × 1017 ions/cm2, and minimum corrosion was detected in the sample with a dose of 5 × 1017 ions/cm2. It can be concluded that not only the implanted layer on the surface is not resistive in the low doses (1 × 1017 ions/cm2) of argon, but also the initial surface is damaged due to high collision rate between ionized atoms, and this cannot protect the surface against corrosion.

Fig. 7
figure 7

SEM images of implanted samples after corrosion test with argon dose a unimplanted, b 1 × 1017 ions/cm2, and c 5 × 1017 ions/cm2, d 7 × 1017 ions/cm2

Corrosion rate decreases by increasing argon dose at 5 × 1017 ions/cm2, but local pitting corrosion is clearly observed on the surfaces of the tantalum samples (Fig. 7c). It is also worth mentioning that the conditions for corrosion have improved according to corrosion morphology and with regard to pit formation. Higher surface roughness leads to an increase of effective surface in contact with the corrosive agent increasing the corrosion attack. With regard to roughness variation in argon implantation, at the fluency of 5 × 1017 ions/cm2, a maximum of roughness is detected which is probably due to difference of surface roughness in two cases.

Conclusion

In this paper, the influences of 30 keV argon ion bombardments on corrosion behavior of the Tantalum samples have been discussed by analyzing the obtained data of AFM. The roughness and corrosion potential curves clearly indicate that corrosion potential variations caused by argon ion implantation are inversely proportional to surface roughness. Hence, according to scanning electron microscopy and corrosion results, this sample (5 × 1017 ions/cm2) presents the highest corrosion resistance against the H2SO4 corroding media. Corrosion current variations in implanted sample indicate an optimal dose at 5 × 1017 ions/cm2 in which the corrosion resistivity is 12 percent in the higher than un-implanted sample. Furthermore, it can be realized that the best resistance against corrosion can be achieved by bombarding with argon.