Experimental Study on Fire Behavior of Steel–Concrete Composite Cellular Beams with Large Opening Ratio

  • Published:
International Journal of Steel Structures Aims and scope Submit manuscript

Abstract

The aim of this study is to examine the behavior of protected and unprotected steel–concrete composite I-beams with large cell diameters (D0/H = 0.7) and closely spaced cell configurations under the ISO 834 fire curve. Previous studies on experimental full-scale fire performances of cellular beams have been somewhat limited under vertical service loads and different insulation properties. To address this limitation, a total of four composite beams, two unprotected (one beam with a solid web, and one cellular beam) and two protected cellular beams (60 min fire resistance with implementation of water and solvent-based intumescent coatings) were tested. As outputs of the tests, the failure modes observed, such as web buckling, the Vierendeel effect, the slab behavior, including the mechanism of concrete cracking, the overall displacement behavior (i.e., deflected shapes) up to collapse at very large deflections, and temperature changes in the steel elements are discussed. It was concluded that the quality of the intumescent coating applied is crucial in achieving the desired fire resistance. Experiments showed that unprotected trapezoid deck voids did not have a decisive influence on the behavior of the beams for up to 60 min of fire testing. At high temperatures, similar crack patterns occurred in the composite slabs of the protected and unprotected steel–concrete composite cellular beams. In the protected beams, the behavior of reactive coatings was significant and resulted in a non-uniform temperature distribution in these beams’ web and flanges.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18
Fig. 19
Fig. 20
Fig. 21
Fig. 22
Fig. 23
Fig. 24
Fig. 25
Fig. 26
Fig. 27
Fig. 28
Fig. 29
Fig. 30

Similar content being viewed by others

References

  • Bailey, C. G. (2004). Indicative fire test to investigate the behaviour of cellular beams protected with intumescent coatings. Fire Safety Journal,39(8), 689–709.

    Article  Google Scholar 

  • Bihina, G., Zhao, B., & Bouchair, A. (2012). Experimental and numerical investigation on the behaviour of a composite floor made of cellular beams in a fire situation. In 7th international conference on structures in fire. ETH Zurich, p. 295.

  • Bihina, G., Zhao, B., & Bouchair, A. (2013). Behaviour of composite steel–concrete cellular beams in fire. Journal of Engineering Structures,56, 2217–2228.

    Article  Google Scholar 

  • BS 476-20. (2014). Fire tests on building materials and structures- Part 20: Method for determination of the fire resistance of elements of construction. London: The British Standards Institution.

    Google Scholar 

  • BYKHY. (2017). Regulations on fire protection of buildings. Official Journal, 19 December 2007, 26735, Turkey, Ankara.

  • Cho, S. H. (1990). Slab behaviour in composite beams at web openings. PhD Thesis, Dep. Civil Eng. and App. Mech., Mc Gill University.

  • Durif, S., Bouchair, A., & Vassart, O. (2013). Validation of an analytical model for curved and tapered cellular beams at normal and fire conditions. Periodica Polytechnica Civil Engineering,57(1), 83–95.

    Article  Google Scholar 

  • EN 1365-3. (1999). Fire resistance tests for loadbearing elements- Part 3: Beams. Comite Europeende Normalisation, The British Standards Institution.

  • EN 1993-1-2, Eurocode 3. (1995). Design of steel structures- Part 1.2: Supplementary rules for structural fire design. Comite Europeende Normalisation, The British Standards Institution.

  • EN 1994-1-2, Eurocode 4 (2005). Design of composite steel and concrete structuresPart 11: Design for fire., Comite Europeende Normalisation. The British Standards Institution.

  • Goode, M. (2009). Fire protection of structural steel in high-rise buildings, GCR 04-872, Building and Fire Research Laboratory, 2004, NIST, Gaithersburg, MDISO 834-1, Fire-resistance Tests- Elements of Building Construction Part 1: General Requirements, International Organization for Standardization.

  • Li, Q. G., Lou, G. B., Zhang, C., & Wang, C. Y. (2012). Assess the fire resistance of intumescent coatings by equivalent constant thermal resistance. Journal of Fire Technology,48, 529–546.

    Article  Google Scholar 

  • Nadjai, A., Bailey, C. G., Han, S. H., Vassart, O., Zhao, B., Hawes, M., et al. (2011). Full-scale fire test on a composite floor slab incorporating long span cellular steel beams. Structural Engineering,21, 18–25.

    Google Scholar 

  • Nadjai, A., Petrou, K., Han, S. H., & Ali, F. (2016). Performance of unprotected and protected cellular beams in fire. Journal of Construction and Building Materials,105, 579–588.

    Article  Google Scholar 

  • Nadjai, A., Vassart, O., Ali, F., Talamona, D., Allam, A., & Hawes, M. (2007). Performance of cellular composite floor beams at elevated temperatures. Fire Safety Journal,42(6–7), 489–497.

    Article  Google Scholar 

  • Naili, E., Nadjai, A., & Ali, F. (2011). Experimental and numerical modelling of cellular beams with circular and elongated web openings at elevated temperatures. Journal of Structural Fire Engineering,2(4), 288–300.

    Article  Google Scholar 

  • Newman, G. M., & Lawson, R. M. (1991). Fire resistance of composite beams technical report SCI-P-109. Ascot: Steel Construction Institute.

    Google Scholar 

  • OASYS (2012). Version 8.3. London: OASYS LTD. http://www.oasys-software.com/.

  • Sanghoon, H., Petrou, K., Naili, E. L, Nadjai, A. & Ali, F. (2012). Behaviour of protected cellular beams having different opening shapes in fire conditions, In M. Fontana, A. Frangi & M. Knobloch (Ed.), 7th international conference on structures in fire (pp. 75–83) Switzerland: ETH Zurich, June 6–8.

  • Sunar Bukulmez, P., & Celik, O. C (2017). Structural fire behaviour and testing of protected and unprotected steel–concrete composite cellular beams. In Conference proceedings of applications of structural fire engineering (pp. 295–303).

  • TS 498. (1997). Design loads for buildings. Ankara: Turkish Standard Institute.

    Google Scholar 

  • TS EN 12504-1. (2010). Testing concrete in structures—Part 1: Cored specimens-taking, examining and testing in compression. Ankara: Turkish Standard Institute.

    Google Scholar 

  • TS EN 1363-1. (2013). Fire resistance—Tests-Part 1: General requirements. Ankara: Turkish Standard Institute.

    Google Scholar 

  • TS EN 1365-3. (2013). Fire resistance tests for non-loadbearing elements—Part 3: Beams. Ankara: Turkish Standard Institute.

    Google Scholar 

  • TS EN ISO 6892-1. (2016). Metallic materials—Tensile testing—Part 1: Method of test at room temperature. Ankara: Turkish Standard Institute.

    Google Scholar 

  • Vassart, O., Bailey, C. G., Bihina, G., Hawes, M., Nadjai, A., Peigneux, C., et al. (2010). Parametrical study on the behaviour of steel and composite cellular beams under fire conditions. In Proceedings of the 6th international conference on structures in fire (SIF’10), East Lansing; 2–4 June, 349–57.

  • Wang, P. J., Ma, N., & Wang, X. D. (2014a). Numerical studies on large deflection behaviors of restrained castellated steel beams in a fire. Journal of Construction Steel Research,100(1), 136–145.

    Article  Google Scholar 

  • Wang, P. J., Wang, X. D., & Liu, M. (2014b). Practical method for calculating the buckling temperature of the web-post in a cellular steel beam in fire. Thin-Walled Structures,85(1), 441–455.

    Article  Google Scholar 

  • Wang, P. J., Wang, X. D., Liu, M., & Zhang, L. (2016). Web-post buckling of fully and partially protected cellular steel beams at elevated temperatures in a fire. Thin-Walled Structures,98, 29–38.

    Article  Google Scholar 

  • Ward, J. K. (1990). Design of composite and non-composite cellular beams (p. 100). Berkhsire: SCI Publication.

    Google Scholar 

  • Wong, V. Y. B., Burgess, I. W., & Plank, R. J. (2010). Experimental and analytical investigations of the behavior of protected composite floor beams with web openings in fire. In Conference proceedings of structures in fire. SIF (pp. 366–373).

Download references

Acknowledgements

This research was supported by the Istanbul Technical University Scientific Research Project Coordination Unit (ITU-BAP) under Project No. 3802, and the Scientific and Technological Research Council of Turkey-1002 Short Term R&D Funding Program (TUBITAK-1002) under Project No. 315M285. GALPAN kindly provided the steel–composite beam specimens. All tests were carried out at Efectis Era Eurasia. However, the opinions, findings, conclusions, and recommendations presented in this paper are those of the authors and do not necessarily reflect the views of the sponsors.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Pınar Sunar Bükülmez.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sunar Bükülmez, P., Celik, O.C. Experimental Study on Fire Behavior of Steel–Concrete Composite Cellular Beams with Large Opening Ratio. Int J Steel Struct 20, 207–231 (2020). https://doi.org/10.1007/s13296-019-00281-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s13296-019-00281-9

Keywords

Navigation