Abstract
This paper deals with the experimental investigation of the removal of the toxic Cr(VI) ions using a low-cost waste biomaterials Psidium guajava leaves as the adsorbent in continuous column mode. The influence of process parameters like bed depth, the rate of flow, and influent concentration on the removal was investigated to determine the adsorption characteristics by this adsorbent. The capacity of the adsorbent for metal uptake was decreased with the increase in bed depth from 4.07 to 2.89 mg g−1, but it was increased with the rise in flow rate from 2.94 to 8.72 mg g−1. The data obtained from the experiment were fitted good with Thomas model. The major functional groups were identified from the FTIR study which was responsible for the adsorption. The guava leaves are suitable for Cr(VI) removal from aqueous solution.
Similar content being viewed by others
Explore related subjects
Discover the latest articles, news and stories from top researchers in related subjects.Avoid common mistakes on your manuscript.
Introduction
The environmentalists are very much concern for the heavy metal ions which are present in the water stream which throws a serious threat to human health and also the environment as they are not biodegradable and toxic (Sousa et al. 2010; Long et al. 2014). So, the most important environmental issue for recent time is the remotion of the toxic heavy metals from the wastewater (Mondal 2009). The metals having the atomic density greater than 4 g cm−3 are termed as heavy metals (Uguzdogan et al. 2010; Kalhori et al. 2013). Among them, hexavalent chromium is known worldwide as a carcinogenic heavy metal with other harmful effects on human health including skin allergy, lever, and pulmonary damage (Dakiky et al. 2002; Setshedi et al. 2015). Cr(VI) ion is released into the aquatic environment from the variety of sources such as electroplating industries, wood preservation, leather tanning, and metal finishing industries (Quintelas et al. 2009; Ye et al. 2010). The international standards like EPA, IS, and WHO set the discharge limit of Cr(VI) ion limit such industries to the environment. These limits are 0.1 mg L−1 for EPA, 0.1 mg L−1 for IS, and 0.05 mg L−1 for WHO, respectively (EPA 1990; IS 1050; WHO 1993). Conventional methods, like chemical precipitation, ion exchange, reverse osmosis, extraction, membrane separation, adsorption using activated carbon, bio-sorption, etc., are used for the remotion of heavy metals from aqueous solution (Ye et al. 2010; Alguacil et al. 2008). Among them, reverse osmosis and membrane separation are too much expensive due to the cost of the membrane. Ion exchange, precipitation, and extraction cannot give the satisfactory result, but the processes are not very effective and also a large amount of sludge formation. Adsorption using activated carbon is also not a cost-effective process due to its high initial cost, and also the regeneration cost is too high. All the methods mentioned above except adsorption are costly and also not eco-friendly. Bio-sorption is an economically cheap process if low-cost waste materials are identified as adsorbents which require an easy operation method (Mitra et al. 2014; Agarwal et al. 2006). Researchers used coconut shell, fly ash, neem leaves, hyacinth root, sawdust, rice husk, rice straw, rice bran, rubber leaf powder, onion peel, mango and bamboo leaf, etc., as green adsorbents for Cr(VI) ion removal from wastewater (Singha et al. 2011; Nag et al. 2017). Hence, a lot of research works are needed with the low-cost, easily available adsorbent to remove or to reduce this environmental problem (Agarwal et al. 2006). Psidium guajava (guava) is a traditional medicinal plant. It is a native of Central America but is now widely cultivated more than fifty countries particularly in tropics, subtropics, and some of the Mediterranean areas. The major cultivators in the world are India, Brazil, and Mexico. South Africa, Jamaica, Kenya, Cuba, the USA (Mainly Florida and Hawaii), Egypt, Columbia, and the Philippines, etc., are the other leading guava producing countries (Shruthi et al. 2013; Hossen 2012). Guava leaves are waste materials and can be used for this process which makes the process economical.
In this study, the adsorbent is introduced as the green adsorbent. The primary sources of green adsorbents are the waste of fruits, vegetables, trees, the bark of the trees and agricultural, bi-products of agricultural waste, etc. These are low cost compared to the treated or modified complex adsorbents. The capacity of these adsorbents is less than the complex adsorbents but cost-potentiality makes the use of green adsorbents greater and competitive (Kyzas and Kostoglou 2014).
The present study deals with the fixed-bed adsorption using guava leaves for Cr(VI) ion removal. The variation of process parameters, like influent concentration, flow rate, bed depth, adsorbent dose, etc., will be carried out. Mathematical modeling for column mode will be performed in this study.
Materials and methods
Guava leaves were collected from guava trees from Kolkata, West Bengal, India. These were washed for several times and dried under the sun for 6–7 days. They were then dried in the oven at 70 °C for 8–9 h and crushed and sieved to get particle sizes of 290–350 µm.
Stock solution of 1000 mg L−1 Cr(VI) was prepared by dissolving 2.829 gm K2Cr2O7 of in distilled water. All the chemicals used are manufactured by E. Merck India Pvt. Ltd. (Mumbai). Pump (Cole-Parmer, model-73 7535-04, USA) was helped to flow the Cr(VI) ion solution to the column. All other instruments used in this study were same as our earlier column experiment (Mitra and Das 2016).
Experimental
Column study
The columns are made of glass of length 50 cm, and the internal diameter of 1.8 cm was used for these experiments (Fig. 1). A metal sieve plate was placed at the bottom of the column, and glass wool was placed above the sieve plate as the preventing measure from the loss of adsorbents to prepare desired bed height. After adding the adsorbent to the column, the distilled water was to be added to make the bed of fixed height. The downward flow of metal ion solution was carried out by using the multichannel peristaltic pump, and from bottom samples were collected at the desired interval of time for Cr(VI) analysis.
Results and discussion
The plot of relative concentration (Ct/C0) versus contact time was used to explain the column performance. Total adsorbed metal ion for a particular flow rate was evaluated by using the following equation,
The equilibrium metal ion uptake was determined using the following equation which is dependent on the weight of the adsorbent,
The height of the mass transfer zone depends on several parameters like flow rate, the rate of mass transfer, and diffusion in pores. Several theoretical predictions had been done to predict the mass transfer zone but some uncertainties in flow pattern make it inaccurate. Hence, it is necessary to experiment in a laboratory scale to scale up the results.
The stoichiometric capacity of the adsorbent used in the bed is determined as follows,
The usable capacity of the adsorbent up to breakthrough time (tb) is given by the following equation,
The length of the bed used to the breakthrough point is calculated as,
The unused bed length is the remaining fraction times the total height of the bed, as
Characteristics of the adsorbent
The physical characteristics of guava leaves were presented in Table 1. Figure 2 represents the photograph of SEM and shows the surface morphology of the raw guava leaves. Function groups present in the unloaded and metal ion-loaded guava leaf is identified by Fourier transform infrared spectra (FTIR) (Fig. 3).
Influence of bed depth
Figure 4 shows the variation of bed depth (4–6 cm). As the increase in bed depth, both the saturation and exhaustion times were increased because more binding sites were available for adsorption. A larger mass transfer zone was found in the greater bed depth. The breakthrough curve characterized by an S-shape whose last part indicated a saturation zone for the process (Mitra and Das 2016).
Variation of flow rate
The variation of different flows rate was shown in Fig. 5. At lower flow rates, the adsorption was very fast as the vacant adsorption sites are more available in the first stage. Gradually, it is decreased in the later stage as the occupancy of those sites by metal ions, and the process becomes less efficient. Figure 5 shows a steeper breakthrough and exhaustion with the increase in the flow rates from 10 to 30 mg L−1. At lower flow rate, the best adsorption performance attained (Kalavathy et al. 2010).
Influence of inlet concentration
Figure 6 shows the variation of inlet concentration. As the increase in influent concentration, the breakthrough time decreased and is due to the rise of mass transfer driving force which resulted from the decrease in the mass transfer zone. It also makes an impact on metal uptake capacity. The uptake capacity decreases with the increase in inlet concentration (Talreja et al. 2014).
Modeling of the column experiment
The laboratory-scale column data need to analyze for developing it in the industrial system. The development of these data is made using well-known kinetic models (Setshedi et al. 2015).
Thomas model (Thomas 1948)
It is a widely used model to explain the performance of the adsorbent in the column study. Based on the Langmuir isotherm theory of sorption, and assumed the second-order reversible reaction kinetics. The model equation is,
The rate constant of the Thomas model and metal uptake capacity was obtained from the plot of ln[C0/Ct − 1] versus t for the above equation and presented in Table 2. The kth value was decreased, and q0 was increased with the increase in influent concentration.
Bohart–Adams modell (Bohart and Adams 1920)
The empirical model is Bohart–Adams model to design the column process. The surface reaction theory is the basis of this model and applicable in the first part in the breakthrough curve. The primary assumption is the adsorption rate is proportional to adsorption capacity. The linearized form of this equation is,
The model rate constant and saturation concentration were determined along with the correlation coefficient from the graph of ln[Ct/C0] versus t which is represented in Table 3. A decreasing trend was followed in the case of saturation concentration with the increased bed depth and flow rate, but the opposite trend was observed in the case of influent concentration. These trends strongly proved the influence of external mass transfer to the sorption process (Malkoc et al. 2006).
Determination of mass transfer zone (Geankoplis et al. 2016)
Using the above Eqs. (3–6), we determined the amount of adsorbent that had been used for the study. From Fig. 7, it is clear that not the whole bed is used for the adsorption process. Although the required bed height was 4 cm, 6 cm, and 10 cm, little amount of adsorbent remain unused. This is because channeling in the bed occurred.
Scale-up design for industrial use
Laboratory testing was done to initialize the industrial scale setup and optimize the adsorption capacity. The best condition used to design the setup in industrial purpose is determined from the best fitted kinetic model.
The volumetric rate of flow for the industrial designed setup is given as below,
here, D can be represented as,
The amount of guava leaves is used to design the process setup in industrial scale is determined using the following equation,
where tR corresponds to the value of Ct which is less than Cd or equal to Cd and Ct is taken from the experimental data. The height of the proposed setup is determined using the below equation,
In this study, Thomas model is fitted well with best correlation coefficient 0.9935. The specification for the pump, glass column, and other accessories should be added to the industrial design. Therefore, the laboratory-scale data should be readjusted to construct an exact design in industrial scale.
FTIR study
Fourier transform infrared spectroscopy (FTIR) is a mechanism which is used to collect an infrared spectrum of absorption of the adsorbent. It is an easy technique to identify the presence of functional groups in a molecule. Figure 3 refers to the FTIR diagram for fresh and Cr(VI) loaded of guava leaf. The shift in wavelength is noticed in the figure. The figure indicates the shift in wave number from 4000 to 400 cm−1 for metal ion unloaded and metal ion-loaded guava leaves which are represented in Table 4. The responsibility of Alkyl C–H stretching is identified from the shifting in wave number from 2931 (unloaded adsorbent) to 2927 cm−1 [Cr(VI) ion-loaded adsorbent]. Aromatic C=C bending is also responsible for the adsorption as the peak in wavelength is shifted from 1623 (unloaded adsorbent) to 1619 cm−1 [Cr(VI) ion-loaded adsorbent]. The shift from 1456 (unloaded adsorbent) to 1445 cm−1 [Cr(VI) ion-loaded adsorbent] indicated the carboxylate anion C=O is stretching, and –SO3 stretching is indicated by the shift from 1240 (unloaded adsorbent) to 1236 cm−1 [Cr(VI) ion-loaded adsorbent]. Alkoxy C–O stretching is also responsible for the respective adsorption as the wave number is shifted from 1104 (unloaded adsorbent) to 1095 cm−1 (metal-loaded adsorbent). The shifting in wave number from 786 (unloaded adsorbent) to 777 cm−1 (metal-loaded adsorbent) and 518 (unloaded adsorbent) to 516 cm−1 (metal-loaded adsorbent) is due to the Alkyl C–Br stretching and aromatic C–H bending; hence, they are also responsible in the metal binding adsorption process.
Conclusions
It is concluded that the guava leaves are capable of adsorbed metal ions in continuous mode. The operating factors like bed depth, flow rate, and influent concentration of metal ion affect the adsorption capacity and breakthrough profiles. Adsorption was best at high bed depth but low rate of flow and influent concentration. Among Thomas and Bohart–Adams models, Thomas model was the best kinetic model. From the FTIR study, the functional groups like alkyl C–H are stretching, aromatic C=C bending, carboxylate anion C=O stretching, SO3 stretching, alkoxy C–O stretching, alkyl C–Br stretching, and aromatic C–H bending was identified as Cr(VI) adsorption. From the mass transfer zone determination, it was established that the total amount of adsorbent in the bed is not used for the sorption process. The scale-up design procedure is described. The guava leaves are useful adsorbent and suitable for Third World countries for remotion of Cr(VI) ions.
Abbreviations
- C ad :
-
Adsorbed concentration (mg L–1)
- C 0 :
-
Influent metal ion concentration at t = 0 (mg L–1)
- C t :
-
Effluent metal ion concentration at time t (mg L–1)
- C t/C 0 :
-
Relative concentration
- C w :
-
Concentration of Cr(VI) in wastewater (mg L–1)
- D :
-
Diameter of the column (cm)
- H :
-
Total height of the column (cm)
- H c :
-
Additional height for the column accessories (cm)
- H U :
-
The length of bed used to breakthrough point (cm)
- H UNU :
-
The length of bed unused (cm)
- K AB :
-
Kinetic constant for Bohart–Adams model (L mg–1)
- k th :
-
Thomas rate constant (L mg–1 min–1)
- N 0 :
-
Saturation concentration (mg L–1)
- q :
-
Adsorption capacity (mg g–1)
- M ad :
-
Amount of adsorbent in the designed tower (g)
- q 0 :
-
Maximum metal uptake per gram of the adsorbent (mg g–1)
- q eq :
-
Equilibrium metal uptake by adsorbent (mg g–1)
- q max :
-
Maximum adsorption capacity of the adsorbent (mg g−1)
- q t :
-
Total adsorbed Cr(VI) at time t (mg)
- q t0 :
-
Total adsorbed Cr(VI) at time t = 0 (mg)
- Q d :
-
Volumetric flow rate at designed column (mL min−1)
- R 2 :
-
Correlation coefficient
- t b :
-
Breakthrough time (min)
- t R :
-
Regeneration time (min)
- t t :
-
Time equilibrium to stoichiometric capacity (min)
- t u :
-
Time equivalent to the usable capacity (min)
- T :
-
Total working time (h)
- u 0 :
-
Superficial velocity (m min−1)
- V eff :
-
Effluent volume (mL)
- x :
-
Amount of adsorbent present in the column (g)
- Z :
-
Bed depth (cm)
- v :
-
Flow rate (mL min–1)
- ρ:
-
Density of the adsorbent (kg m3)
References
Agarwal GS, Bhuptawat HK, Chaudhari S (2006) Biosorption of aqueous chromium (VI) by Tamarindus indica seeds. Bioresour Technol 97:949
Alguacil FJ, Alonso M, Lopez F, Lopez-Delgado A (2008) Uphill permeation of Cr(VI) using Hostarex A327 as ionophore by membrane-solvent extraction processing. Chemosphere 72:684
Bohart G, Adams EN (1920) Some aspects of the behavior of charcoal with respect to chlorine. J Am Chem Soc 42:523
Dakiky M, Khami A, Manassra A, Mer’eb M (2002) Selective adsorption of chromium (VI) in industrial wastewater using low-cost abundantly available adsorbents. Adv Environ Res 6(4):533
EPA (1990) Environmental Protection Agency, Cincinnati OH USA
Geankoplis CJ (2016) Transport processes and separation processes principles, 4th edn. Prentice-Hall of India Pvt. Ltd., New Delhi, India
Hossen SM (2012) Statistical analysis of current guava production and its prospect in Bangladesh. Asian Bus Rev 1(1):9
IS 10500:1991 (1991) Bureau of Indian standards, Drinking Water Specifications, New Delhi
Kalavathy H, Karthik B, Miranda LR (2010) Removal and recovery of Ni and Zn from aqueous solution using activated carbon from Hevea brasiliensis: batch and column studies. Colloids Surf B Biointerfaces 78:291
Kalhori EM, Yetilmezsoy K, Uygur N, Zarrabi M, Abu Shmeis RM (2013) Modeling of adsorption of toxic chromium on natural and surface modified lightweight expanded clay aggregate (LECA). Appl Surf Sci 287:428
Kyzas GZ, Kostoglou M (2014) Green adsorbents for wastewaters: a critical review. Materials 7:333
Long Y, Lei D, Ni J, Ren Z, Chen C, Xu H (2014) Packed bed column studies on lead(II) removal from industrial wastewater by modified Agaricus bisporus. Bioresour Technol 152:457
Malkoc E, Nuhoglu Y, Dundar M (2006) Adsorption of chromium(VI) on pomace—an olive oil industry waste: batch and column study. J Hazard Mater B138:142
Mitra T, Das SK (2016) Adsorptive removal of Cr(VI) from aqueous solution using blackberry leaves—column study. Int J Environ Eng 8(4):225
Mitra T, Singha B, Bar N, Das SK (2014) Removal of Pb(II) ions from aqueous solution using water hyacinth root by fixed-bed column and ANN modelling. J Hazard Mater 273:94
Mondal MK (2009) Removal of Pb(II) ions from aqueous solution using activated tea waste: adsorption on a fixed-bed column. J Environ Manage 90:3266
Nag S, Mondal A, Bar N, Das SK (2017) Biosorption of chromium (VI) from aqueous solutions and ANN modelling. Environ Sci Pollut Res 24(23):18817
Quintelas C, Fonseca B, Silva B, Figueiredo H, Tavares T (2009) Treatment of chromium(VI) solutions in a pilot-scale bioreactor through a biofilm of Arthrobacter viscosus supported on GAC. Bioresour Technol 100:220
Setshedi KZ, Bhaumik M, Onyango MS, Maity A (2015) High-performance towards Cr(VI) removal using multi-active sites of polypyrrole–graphene oxide nanocomposites: batch and column studies. Chem Eng J 262:921
Shruthi SD, Roshan A, Timilsina SS, Sunita S (2013) A review on the medicinal plant Psidium guajava Linn. (Myrtaceae). J Drug Deliv Ther 3(2):162
Singha B, Naiya TK, Bhattacharya AK, Das SK (2011) Cr(VI) ions removal from aqueous solutions using natural adsorbents—FTIR studies. J Environ Prot 2:729
Sousa FW, Oliveira AG, Ribeiro JP, Rosa MF, Keukeleire D, Nascimento RF (2010) Green coconut shells applied as adsorbent for removal of toxic metal ions using fixed-bed column technology. J Environ Manage 91:1634
Talreja N, Kumar D, Verma N (2014) Removal of hexavalent chromium from water using Fe-grown carbon nanofibers containing porous carbon microbeads. J Water Proc Eng 3:34
Thomas HG (1948) Chromatography: a problem in kinetics. Ann N Y Acad Sci 49:161
Uguzdogan E, Denkbas EB, Kabasakal OS (2010) The use of polyethyleneglycolmethacrylate-co-vinylimidazole (PEGMA-co-VI) micro-spheres for the removal of nickel(II) and chromium(VI) ions. J Hazard Mater 177:119
WHO (1993) Guidelines for drinking water quality, vol 1. World Health Organization, Geneva, p 52
Ye J, Yin H, Mai B, Peng H, Qin H, He B, Zhang N (2010) Biosorption of chromium from aqueous solution and electroplating wastewater using mixture of Candida lipolytica and dewatered sewage sludge. Bioresour Technol 101:3893
Acknowledgements
Authors are thankful to DST, Government of West Bengal for the project [Sanction order No. 211(Sanc.)/ST/P/S&T/13G-1/2013, dated–06.06.2014]. T. Mitra is thankful to TEQIP Phase-II [Ref. No. TEQIP-II/ACA/86 (4/2), dated 18.09.2013], University of Calcutta for her fellowship.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
No conflict of interest is confirmed.
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
About this article
Cite this article
Mitra, T., Das, S.K. Cr(VI) removal from aqueous solution using Psidium guajava leaves as green adsorbent: column studies. Appl Water Sci 9, 153 (2019). https://doi.org/10.1007/s13201-019-1029-2
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s13201-019-1029-2