Hypersensitivity to Titanium: A Less Explored Area of Research

  • Review Article
  • Published:
The Journal of Indian Prosthodontic Society

Abstract

Titanium is considered as an excellent biocompatible metal and it is used in implant dentistry. Literature suggests that Ti can induce clinically relevant hypersensitivity and other immune dysfunctions in certain patients chronically exposed to this reactive metal. At the same time, no standard patch test for Ti has so far been developed, and positive reactions to Ti have therefore only rarely been demonstrated with skin testing. This article reports about the corrosion of dental implants, their significance when hypersensitivity is present, and the literature available till date regarding hypersensitivity of titanium.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Bhola R, Bhola SM, Mishra B, Olson DL (2011) Corrosion in titanium dental implants/prostheses: a review. trends biomater. Artif Organs 25:34–46

    Google Scholar 

  2. Mitchell DL, Synnott SA, VanDercreek JA (1990) Tissue reaction involving an intraoral skin graft and cp titanium abutments: a clinical report. Int J Oral Maxillofac Implants 5:79–84

    PubMed  Google Scholar 

  3. Katou F, Andoh N, Motegi K, Nagura H (1996) Immuno-inflammatory responses in the tissue adjacent to titanium miniplates used in the treatment of mandibular fractures. J Crainiomaxillofac Surg 24:156–162

    Google Scholar 

  4. Kovacs P, Davidson JA (1996) Chemical and electrochemical aspects of the biocompatibility of titanium and its alloys. In: Brown SA, Lemons JE (ed). Medical application of titanium and its alloys. The material and biological issue, ASTM STP 1272. ASTM, West Conshohocken , pp 63–78

  5. Zitter H, Plenk H (1987) The electrochemical behavior of metallic implant materials as an indicator of their biocompatibility. J Biomed Mater Res 21:881–896

    Article  PubMed  Google Scholar 

  6. Joshi VA (2006) Physical metallurgy of titanium alloys. Titanium alloys an atlas of structures and fracture features. CRC Press, pp 7–15

  7. Schutz RW (1993) An overview of beta titanium alloys environmental behavior. In: Eylon D, Boyer RR, Koss DA (eds) Beta titanium alloys in the 1990’s. The Mineral, Metals and Materials Society, Warrendale, pp 75–91

    Google Scholar 

  8. Bozinni B, Carlino P, Urzo LD, Pepe V, Mele C, Venturo F (2008) An electrochemical impedance investigation of the behavior of anodically oxidized titanium in human plasma and cognate fluids, relevant to dental applications. J Mater Sci Mater Med 19:3443–3453

    Article  Google Scholar 

  9. Leinfelder KF, Lemons JE (1998) Clinical restorative materials and techniques. Ler and Febiger, Philadelphia, pp 139–159

    Google Scholar 

  10. Lucas LC, Lemons JE (1992) Biodegradation of restorative metallic systems. Adv Dent Res 6:32–37

    PubMed  Google Scholar 

  11. Holgers KM, Roupe G, Tjellstrom A, Bjursten LM (1992) Clinical, immunological and bacteriological evaluation of adverse reactions to skin-penetrating titanium implants in the head and neck region. Contact Dermat 27:1–7

    Article  Google Scholar 

  12. Hallab NJ, Mikecz K, Vermes C, Skipor A, Jacobs JJ (2001) Orthopaedic implant related metal toxicity in terms of human lymphocyte reactivity to metal–protein complexes produced from cobalt-base and titanium base implant alloy degradation. Mol Cell Biochem 222:127–136

    Article  PubMed  Google Scholar 

  13. Sato N (1989) Towards a more fundamental understanding of corrosion processes. Corrosion 45:54–368

    Article  Google Scholar 

  14. Gat N, Tabakoff W (1980) Effects of temperature on the behavior of metals under erosion by particulate matter. J Test Eval 8:177–186

    Article  Google Scholar 

  15. Sprowls DO (1987) Metals handbook, vol 13, corrosion 9th edn. ASM International, Metals Park, pp 222–25

  16. Jones DA (1982) Forms of corrosion recognition and prevention. Dillion CP, NACE, Houston, pp 19–43

    Google Scholar 

  17. RW Schutz (1992) Stress-corrosion cracking of titanium alloys, stress-corrosion cracking. In: Jones RH (ed) ASM International, pp 265–97

  18. Tomashov ND, Altovskii PM (1963) Corrosion and protection of titanium, Government scientific-technical publication of machine-building literature (Russian translation)

  19. Weighed P, Geode (2002) Geodynamics and ore deposit evolution. European Science Foundation, Strasbourg

    Google Scholar 

  20. Parr GR, Gardner LK, Toth RW (1985) Titanium: the mystery metal of implants dentistry. Dental materials aspects. J Prosthet Dent 54:410–414

    Article  PubMed  Google Scholar 

  21. Rogers SD, Howie DW, Graves SE, Pearcy MJ, Haynes DR (1997) In vitro human monocyte response to wear particles of titanium alloys containing niobium and vanadium. J Bone Joint Surg 79 (B):311–315

    Article  Google Scholar 

  22. Hallab N, Merritt K, Jacobs JJ (1997) Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg Am 83A:428–436

    Google Scholar 

  23. Schramm M, Pitto RP (2000) Clinical relevance of allergological tests in total hip joint replacement. In: Willmann G, Zweymüller K (eds) Bio ceramics in hip joint replacement

  24. Sicilia A, Cuesta S, Coma G, Arregui I, Guisasola C, Ruiz E et al (2008) Titanium allergy in dental implant patients. Clin Oral Impl Res 19:823–835

    Article  Google Scholar 

  25. Okamura T, Morimoto M, Fukushima D, Yamane G (1999) A skin patch test for the diagnosis of titanium allergy. J Dent Res 78:1135

    Google Scholar 

  26. Halpern B, Amache N (1967) Diagnosis of drug allergy in vitro with the lymphocyte transformation test. J Allergy 40:168–181

    Article  PubMed  Google Scholar 

  27. Stejskal VDM, Forsbeck M, Nilsson R (1990) Lymphocyte transformation test for diagnosis of isothiazolinone allergy in man. J Invest Dermatol 94:798–802

    Article  PubMed  Google Scholar 

  28. Lymphocyte transformation test. Blue Cross and Blue Shield of Texas, a Division of Health Care Service Corporation, a Mutual Legal Reserve Company, Southwest Texas HMO, Inc. HMO Blue Cross Texas.Independent Licensees of the Blue Cross and Blue Shield Association.med207.093. posted date: 8/22/2003 effective date: 12/1/2003

  29. Stejskal V, Cederbrant K, Lindvall A, Forsbeck M (1994) MELISA-An in vitro tool for the study of metal allergy. Toxicol in Vitro 8:991–1000

    Article  PubMed  Google Scholar 

  30. Müller K, Valentine-Thon E (2006) Hypersensitivity to titanium: clinical and laboratory evidence. Neuro Endocrinol Lett 27:31–35

    PubMed  Google Scholar 

  31. Merritt K, Rodrigo JJ (1996) Immune response to synthetic materials. sensitization of patients receiving orthopaedic implants. Clin Orthop Relat Res 326:71–79

    Article  PubMed  Google Scholar 

  32. Peeters MS, Schroeter AL, Van Hale HM, Broadbent JC (1984) Pacemaker contact sensitivity. Contact Dermat 11:218–220

    Article  Google Scholar 

  33. Yamauchi R, Morita A, Tsuji T (2000) Pacemaker dermatitis from titanium. Contact Dermat 42:52–53

    Google Scholar 

  34. Brunski JB, Puleo DA, Nanci A (2000) Biomaterials and biomechanics of oral and maxillofacial implants: current status and future developments. Int J Oral Maxillofac Implants 15:15–46

    PubMed  Google Scholar 

  35. Akagawa Y, Abe Y (2003) Titanium: the ultimate solution or an evolutionary step? Int J Prosthodont 16(Suppl.):28–29 (discussion 47–51)

    PubMed  Google Scholar 

  36. Bass JK, Fine H, Cisneros GJ (1993) Nickel hypersensitivity in the orthodontic patient. Am J Orthod Dentofacial Orthop 103:280–285

    Article  PubMed  Google Scholar 

  37. Mitchell DL, Synnott SA, VanDercreek JA (1990) Tissue reaction involving an intraoral skin graft and CP titanium abutments: a clinical report. Int J Oral Maxillofac Surg 5:79–84

    Google Scholar 

  38. Nakashima Y, Sun D-H, Trindade M, Maloney W, Goodman S, Schurman D et al (1999) Signaling pathways for tumor necrosis factor-α and interleukin-6 expression in human macrophages exposed to titanium-alloy particulate debris in vitro. J Bone Joint Surg 81:603–615

    Article  PubMed  Google Scholar 

  39. Egusa et al (2008) Suspected association of an allergic reaction with titanium dental implants: a clinical report. J Prosthet Dent 100:344–347

    Article  Google Scholar 

  40. Nawaz F, Wall BM (2007) Drug rash with eosinophilia and systemic symptoms (DRESS) syndrome: suspected association with titanium bioprosthesis. Am J Med Sci 334:215–218

    Article  PubMed  Google Scholar 

  41. Weingart D, Steinemann S, Schilli W, Strub JR, Hellerich U, Assenmacher J et al (1994) Titanium deposition in regional lymph nodes after insertion of titanium screw implants in maxillofacial region. Int J Oral Maxillofac Surg 23:450–452

    Article  PubMed  Google Scholar 

  42. Thomas P, Brandl W, Majer S, Summer B, Przybilla B (2006) Hypersensitivity to titanium osteosynthesis with impaired fracture healing, eczema and T-cell hyper responsiveness in vitro: case report and review of the literature. Contact dermat 55:199–202

    Article  Google Scholar 

  43. Frisken KW, Dandie GW, Lugowski S, Jordan G (2002) A study of titanium release into body organs following the insertion of single threaded screw implants into the mandibles of sheep. Aust Dent J 47:214–217

    Article  PubMed  Google Scholar 

  44. Watterhahn KE, Demple B, Kulesz MM, Copeland ES (1992) Carcinogenesis: a chemical pathology study section workshop, workshop report from the division of research grants, NIH. Cancer Res 52:4058–4063

    Google Scholar 

  45. Green NT, Machtei EE, Horwitz J et al (2002) Fracture of dental implants: literature review and report of a case. Implant Dent 11:137–143

    Article  Google Scholar 

  46. Yokoyama K, Ichikawa T, Murakami H, Miyamoto Y, Asaoka K (2002) Fracture mechanics of retrieved titanium screw thread in dental implant. Biomaterials 23:2459–2465

    Article  PubMed  Google Scholar 

  47. Oliva X, Oliva J, oliva JD (2010) Full-mouth oral rehabilitation in a titanium allergy patient using zirconium oxide dental implants and zirconium oxide restorations. A case report from an ongoing clinical study. Eur J esthet dent 5:190–203

    PubMed  Google Scholar 

  48. Forte G, Petrucci F, Bocca B (2008) Metal allergens of growing significance: epidemiology, immunotoxicology, strategies for testing and prevention. Inflamm Allergy 7:1–18

    Article  Google Scholar 

  49. Oboki K, Ohno T, Saito H, Nakae S (2008) Th17 and allergy. Allergol Int 57:121–134

    Article  PubMed  Google Scholar 

  50. Ricciardi L, Minciullo P, Saitta P, Trombetta D, Saija A, Gangemi S (2009) Increased serum levels of IL-22 in patients with nickel contact dermatitis. Contact Dermat 60:57–58

    Article  Google Scholar 

  51. Laurence E (2011) Titanium: a new allergen. Implant dentistry a rapidly evolving practice 531–44. doi:10.5772/19931

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Vasantha Vijayaraghavan.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Vijayaraghavan, V., Sabane, A.V. & Tejas, K. Hypersensitivity to Titanium: A Less Explored Area of Research. J Indian Prosthodont Soc 12, 201–207 (2012). https://doi.org/10.1007/s13191-012-0139-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s13191-012-0139-4

Keywords

Navigation