Abstract
Compared to rotational atherectomy (RA), orbital atherectomy (OA) has been shown to decrease procedure failure and reintervention rates in the treatment of severely calcified coronary artery lesions. Our objective was to explore the cost-effectiveness of OA compared to RA in the Japanese healthcare system. A decision-analytic model calculated reintervention rates and consequent total 1-year costs. Effectiveness inputs were therapy-specific target lesion revascularization (TLR) rates and all-cause mortality, pooled from clinical studies. Index and reintervention costs were determined based on claims data analysis of n = 33,628 subjects treated in 2014–2016. We computed incremental cost-effectiveness in Japanese Yen (JPY) per life year (LY) gained based on differences in 1-year cost and projected long-term survival, assuming OA device cost between JPY 350,000 and JPY 550,000. OA was found to be associated with improved clinical outcomes (12-month TLR rate 5.0 vs. 15.7%) and projected survival gain (8.34 vs. 8.16 LYs (+0.17), based on 1-year mortality of 5.5 vs. 6.8%). Total 1-year costs were lower for device cost of JPY 430,000 or less, and reached a maximum ICER of JPY 753,445 per LY at the highest assumed device cost, making OA dominant or cost-effective across the tested range, at ICERs substantially below the willingness-to-pay threshold. In conclusion, orbital atherectomy for the treatment of severely calcified coronary artery lesions, compared to rotational atherectomy, is a cost-effective treatment approach in the Japanese healthcare system due to improved clinical performance.
Similar content being viewed by others
Avoid common mistakes on your manuscript.
Introduction
The treatment of severely calcified coronary artery lesions continues to present a clinical and economic challenge. Factors that lead to coronary calcification such as advanced age, diabetes, kidney disease, and smoking are increasing in the US and Japan, and contribute to continued growth of this burden. Compared to less calcified coronary artery lesions, patients with severe calcification have been shown to have worse outcomes [1].
Endovascular treatment of severely calcified coronary lesions is challenging, as these lesions tend to respond poorly to balloon angioplasty, are commonly difficult to completely dilate, and are prone to dissection. Calcium has been found to be associated with stent underexpansion, asymmetric expansion, stent strut malapposition, as well as impaired drug absorption [2, 3]; thus, severely calcified coronary lesions have been excluded from most clinical trials. As a result of this complexity, treatment of severe coronary artery calcification has been shown to lead to longer treatment times, higher resource use, longer hospital stay, and, in consequence, higher treatment costs [1, 4, 5] compared to lesions with little or no calcium.
Atherectomy has emerged as a promising, and sometimes the only viable, treatment option for calcified coronary lesions. Rotational atherectomy (RA) with the Rotablator (Boston Scientific, Natick, MA, USA) is the most widely adopted atherectomy approach for severely calcified coronary lesions to-date in Japan [6, 7], despite having no specific indication for treatment of severe coronary calcium. RA works in a drill-like fashion, producing a 1:1 burr:lumen ratio during treatment of coronary plaque. Orbital atherectomy (OA; Cardiovascular Systems, Inc. St. Paul, MN, USA) is a more recent atherectomy treatment approach with a US Food and Drug Administration indication specific to severe coronary calcium. In contrast to a rotational mechanism of action, OA utilizes centrifugal force allowing for 360° contact of the vessel wall and treatment of variable artery sizes with one device size. Clinical and cost-effectiveness studies of OA in the US have demonstrated reduced procedure complexity and improved patient outcomes [8,9,10]. OA is commercially marketed only in the US, and is currently awaiting regulatory approval and commercial market entry in Japan.
Our objective was to explore the potential cost-effectiveness of OA compared to RA treatment of severely calcified coronary artery lesions in the Japanese healthcare setting, based on latest cost and clinical data.
Methods
We developed a decision-analytic model to assess treatment-specific 1-year total cost to Japanese healthcare payers, and to estimate projected life year gain based on trial-observed 12-month mortality data. Based on these data, our primary health-economic outcome measure, the incremental cost-effectiveness ratio (ICER), was computed. The ICER, defined in our study as the incremental direct costs of medical treatment and consequences divided by the incremental health benefits expressed as life years (LYs), is a common metric used in health-economic analyses to assess the value of an intervention [11], and is outlined in Japan’s recently published Guideline for Preparing Cost-Effectiveness Evaluation to the Central Social Insurance Medical Council.
Therapy effectiveness (target lesion revascularization rate, TLR, and all-cause mortality) was determined based on pooled results of clinical studies identified for each strategy through controlled literature review. Where available, studies reporting on Japanese patient populations were used. Cost data were determined from a detailed analysis of claims data from a large Japanese hospital administrative database, and from estimated index procedure device costs and reintervention costs.
Clinical data
Controlled searches of the published literature were performed in July 2016 to identify relevant clinical studies for inclusion in the analysis. Both prospective and retrospective studies were included. To ensure statistically robust sample sizes, we required sample sizes of n = 50 or greater for inclusion. Furthermore, studies had to report 12-month TLRs (or, really, proportions) and/or 12-month all-cause mortality. As unprotected left main lesions were excluded in the present OA studies, we excluded RA studies that report on these lesion types, to ensure comparability.
Cost data
Procedure costs were derived from a retrospective analysis of cost data from a large hospital administrative database (MDV database, Medical Data Vision, Tokyo, Japan) covering 230 hospitals and 12.94 million patients in Japan. We assumed reimbursement payment amounts to be proxies for true costs and analyzed claims recorded in the period April 2014–March 2016, capturing rotational atherectomy cases (procedure code 150284310), as well as percutaneous coronary intervention (PCI) cases performed with or without stents (procedure codes 150375110 and 150375410, respectively). Both index procedure costs and costs of the first reintervention treatment were determined.
Furthermore, RA device costs were determined based on current Japanese device reimbursement payment amounts for rotational atherectomy devices (Rotablator) and the device-specific guidewire (RotaWire). Total device costs considered the average number of burrs used in the RA procedure, which for the base case was assumed as 1.63 based on Matsuo et al. [12]. OA device costs took into account utilization of 1.08 devices based on weighted pooling of utilization in the ORBIT II and COAST studies [9, 13], and assumed the device-specific guidewire (ViperWire) and one device-specific lubricant (ViperSlide). Whereas OA device costs have not been established in Japan yet, the analysis explored a range of potential reimbursement amounts between JPY 350,000 and JPY 550,000. The lower bound of JPY 350,000 was defined as a reference case reflecting reimbursement for RA, based on JPY 215,000 RA device cost and assumed utilization of 1.63 RA devices per procedure (see Table 1 for details on all additional input assumptions).
Estimation of long-term survival
Differences in long-term survival were based on observed differences in 1-year all-cause mortality between the two treatment strategies, in conjunction with an assessment of the expected remaining life years at the cohort’s age at 1-year follow-up. To adjust age- and gender-specific mortality of the Japanese general population to the cohort of patients with severely calcified coronary artery disease, a relative mortality risk of 2.593 was derived from a study investigating long-term outcome of 25,253 patients with severe coronary artery calcification [14] (see supplementary materials for detailed computations). At age 74 (treatment age of 73 plus 1 year of follow-up), the remaining life expectancy was thus 7.72 years, compared to 13.51 years reported in latest Japanese life tables.
Model-based calculation of costs and estimated cost-effectiveness
The computational model used the claims data-derived RA index hospitalization costs and subtracted RA device costs to obtain index hospitalization costs excluding devices. The model assumed that these index hospitalization costs would be the same for RA-treated and OA-treated patients. Strategy-specific total index hospitalization costs were thus computed by adding RA device costs and OA device costs, respectively. Furthermore, the model considered estimated reintervention cost through 1 year, on the basis of strategy-specific 12-month TLR data. The cost per reintervention was based on the claims data analysis, and considered the aggregate cost of reintervention across all index procedure types (rotational atherectomy, PCI without stent, and PCI with stent). Total computed 1-year costs were the sum of index procedure and applicable reintervention cost.
Model outcomes were the difference in 1-year cost, and the incremental cost-effectiveness computed as the ratio of cost difference and life year difference between the two strategies. No discounting was applied because of the limited 1-year horizon of the costing analysis.
Cost-effectiveness computations and sensitivity analyses
The analysis considered a range of potential OA device cost between JPY 350,000 and JPY 550,000, and the assumptions are shown in Table 1. Extensive one-way sensitivity analyses were conducted, exploring the effect of variation in individual model parameters. In the absence of a final reimbursement amount, these sensitivity analyses were performed around a base case scenario defined by an OA device cost that would lead to overall cost neutrality between the two treatment strategies. Parameters tested in sensitivity analysis included cost data, clinical effectiveness data, and mortality data, as specified in Table 1.
Results
Clinical data
The conducted search identified a total of four RA studies with combined sample size of 667 patients meeting inclusion criteria [6, 7, 15, 16]. One-year TLR rates in these studies ranged from 9.7 to 21.2%. The weighted average was 15.7%. One-year all-cause mortality was reported in three of the four studies, and ranged from 1.6 to 11.5%, resulting in a weighted average of 6.8%.
For OA, two technologies currently exist, Diamondback 360 Coronary Orbital Atherectomy System Micro Classic Crown (OAS Classic Crown) and Diamondback 360 Coronary Orbital Atherectomy System Micro Crown (OAS Micro Crown). The latter, second-generation technology (OAS Micro Crown) has recently been studied in Japanese and US patients in the COAST study, a prospective single-arm multi-center study of n = 100 subjects (ClinicalTrials.gov identifier NCT01092416) [13]. It is currently undergoing regulatory review in Japan and the US, and will be the commercially available OA system in Japan once regulatory approval is granted. The COAST study is the only study reporting on the OAS Micro Crown. The prior generation OAS Classic Crown device has previously been studied in the ORBIT II single-arm, multi-center prospective study (n = 443 patients, ClinicalTrials.gov identifier NCT02132611) [9, 10]. As there was no material difference between 1-year MACE and TVR/TLR rates between COAST and ORBIT II (p = 0.2228 and p = 0.2121, respectively; no overlap of 95% confidence intervals), ORBIT II data were included in our analysis to achieve a higher and more robust sample size (total n = 543). One-year TLR rates were 4.7% in ORBIT II and 6.3% in COAST, for weighted average of 5.0%. Twelve-month all-cause mortality was 4.4 and 6.0%, respectively, resulting in a weighted average of 4.7% (see Table 2 for further detail on cohort characteristics).
Costs
Claims data were available for a total of n = 33,628 patients undergoing index procedure treatment. N = 1373 of these involved RA treatment, with mean patient age of 73.1 years in this subcohort. The mean total index procedure cost was JPY 2,504,198 for RA-treated patients and JPY 1,584,074 for patients treated with other PCI with or without the use of stents. A total of n = 7288 first reinterventions were reported in the claims analysis, with average reintervention cost of JPY 1,184,220 (see supplementary materials for further information and distributional information on all index procedure and reintervention costs).
Subtracting estimated RA device cost of JPY 365,850 from the total RA index hospitalization cost yielded a total cost excluding devices of JPY 2,138,348. This amount was used as the basis for OA total cost estimation. Upon adding estimated OA device and accessories cost of JPY 531,080, total index hospitalization cost for OA patients amounted to JPY 2,669,428, a JPY 165,230 increase in cost compared to RA index cost. Based on the identified 12-month TLR rates for OA and RA, 1-year reintervention costs amounted to JPY 59,091 and JPY 185,563 per cohort patient.
Cost-effectiveness results for tested OA device cost
At the lowest tested OA device cost of JPY 350,000, total 1-year costs (index procedure and applicable first reinterventions) were JPY 2,603,239 and JPY 2,689,761 for OA and RA, respectively, resulting in an OA-associated cost savings to healthcare payers of JPY 86,522 (see Fig. 1). Mean projected LYs were 8.34 for OA and 8.16 for RA (+0.17 LYs), resulting in dominance of the OA strategy. OA remained the dominant strategy up to an OA device cost of JPY 430,100, which can hence be considered the cost-neutral device cost. OA device costs higher than this amount led to gradually increasing incremental cost between the two strategies. At the highest tested OA device cost of JPY 550,000, OA was found to be associated with total 1-year cost of JPY 2,819,239, an increase of JPY 129,478 compared to the OA strategy. In conjunction with the OA-associated outcome improvement of 0.17 LY, this resulted in a maximum ICER of JPY 753,445 per LY gained (see Fig. 2).
Scenario analysis results
Varying the clinical parameter assumptions, assumed device utilization, and device as well as procedure cost assumptions around the cost-neutral base case scenario showed robust findings, with OA being dominant or cost-effective across all tested scenarios, except for an extreme scenario, where RA 1-year mortality was lower than the mortality assumed for the OA base case [see Table 3 for details (as well as extended tables in supplementary materials)].
Discussion
Our analysis found current treatment of severely calcified lesions in the Japanese healthcare system to be associated with substantially increased costs compared to treatment of non-calcified lesions. Index procedure costs of patients treated with rotational atherectomy treatment were almost 60% higher than PCI treatment cost in other patients with coronary artery disease. This underscores the substantial economic burden associated with the treatment of severe calcification.
In response to the main objective of our analysis, we explored the potential health-economic profile of orbital atherectomy as a new endovascular treatment option in the Japanese healthcare system. Our findings suggest a promising health-economic profile of OA when compared to RA treatment, with OA projected to provide improved patient outcomes at either cost savings or marginally increased total cost that renders it a high value intervention. These findings result from the substantially (5.0 vs. 15.7%) lower 12-month TLR rate as well as a slightly lower mortality rate (4.7 vs. 6.8%) associated with OA and were robust across a broad spectrum of clinical, utilization, and cost assumptions, with OA showing dominance in scenarios, where OA device costs were lower than JPY 430,100. Across all tested scenarios, the highest incremental cost-effectiveness ratio and, therefore, least favorable result were JPY 753,000, still denoting high value in light of cited Japanese willingness-to-pay thresholds of JPY 5 million to JPY 11 million, as defined in prior publications [17] and the World Health Organization’s recommendation of country-specific willingness-to-pay thresholds of 3 times per-capita GDP.
The results of our study are generally in line with findings of prior studies investigating the cost-effectiveness of OA. Chambers et al. conducted a cost-effectiveness analysis of OA in severely calcified lesions in the US setting, using ORBIT II data to compare OA to other PCI treatment [18]. Similar to the current study—the analysis was found OA to be associated with higher index procedure costs that were more than offset by a reduction in reintervention costs, and with a survival benefit for OA-treated patients. OA was found to be highly cost-effective and likely cost saving. At 2-year follow-up, the attractive value proposition of OA was confirmed in a follow-on study published by the same author group [19]. Shlofmitz and Martinsen performed a retrospective, single-center study of 61 consecutive cases (31 OA vs. 30 non-OA PCI), and likewise found OA to be cost-effective, at a favorable ICER around $15,000 per quality-adjusted life year (QALY) gained. Finally, Chambers and Diage estimated the cost impact of OA treatment to US Medicare payers, based on ORBIT II event rates, and projected savings of $1100 to the healthcare system within the first year [8].
Among the strengths of our analysis is the detailed procedure cost accounting, which was based on a detailed claims data analysis of the Japanese healthcare system. This analysis covered a very recent timeframe (2014–2016), encompassed a comprehensive set of more than 30,000 claims, and provided specific cost information for RA index procedures and for reinterventions. These procedure cost data, in conjunction with a detailed accounting of RA device utilization and current device reimbursement, facilitated a solid assessment of the base cost of interventional treatment of patients presenting with severely calcified coronary artery lesions.
Limitations
At the same time, our study is subject to several limitations. First, like most model-based analyses, our study makes a number of simplifying assumptions. The cost analysis considered only a 1-year follow-up horizon post-index procedure, and only up to one reintervention—while in reality, some patients might experience more than one reintervention, and also reinterventions at follow-up horizons beyond 1 year. However, most of the clinical data on RA is limited to 1 year of follow-up. Data from those studies reporting longer follow-up—such as ORBIT II [10]—suggest that most reinterventions occur within the first year. Potential consideration of longer follow-up horizons and of more than one reinterventions would likely have made health-economic results for OA more favorable, as it was found to be associated with fewer first reinterventions, and hence likely lower repeat reinterventions. A similar limitation holds for the estimation of life year differences between the two strategies, which was only based on 1-year difference in mortality. Considering 2-year or longer term mortality rates, if available, would have increased the accuracy of projections. Limiting the horizon to 1 year, again, reflected a likely conservative estimate of the outcome benefit associated with OA. Second, while RA data included in the study were—intentionally—limited to results from trials conducted in the Japanese healthcare system, we opted to include OA data from ORBIT II, a large US-based study. However, as has been shown, the outcomes of ORBIT II and of the COAST study, which included US and Japanese patients, did not meaningfully differ. The larger sample size resulting from this approach increases the overall accuracy of the model projections. Furthermore, we explored in sensitivity analyses the effect of using COAST data only. Third, OA is only about to receive regulatory approval in Japan, and reimbursement has not yet been determined for OA. However, in the absence of a fixed reimbursement amount, we explored a broad potential range of device costs, and found OA to be at least cost-effective and potentially dominant across this full range of device costs, underscoring the robustness of the overarching findings. Fourth, device utilization, and specifically the number of burrs used in RA, affects the overarching cost-effectiveness results, and related practice patterns might vary. As the four RA studies included in this analysis did not report absolute numbers of RA burrs used, we relied on data from an earlier study of 200 patients reported by Matsuo et al. [12] to inform device utilization. Their reported number of 1.63 burrs per procedure is in keeping with earlier experience reported in the US [20]. However, there are also a limited number of studies reporting lower utilization as well as higher utilization of RA burrs. Thus, we tested in sensitivity analyses the effect of lower or higher numbers of RA devices used. While reducing the number of RA burrs, as expected, reduced OA-associated cost savings, OA remained cost-effective even for extreme assumptions. Fifth, our analysis results are not discounted, while cost-effectiveness studies reporting longer term projections are typically reported both as discounted and undiscounted values. However, our cost analysis only covered a 1-year timeframe, in which any discounting would have a negligible effect. Furthermore, long-term survival beyond 1 year, aside from difference in 1-year mortality, was assumed to be the same for both strategies, i.e., any differences in outcomes would result from occurrence in the first year. Hence, discounting would have had minimal, if any, effect. Finally, our cost analysis does not take into account potential additional safety benefits and cost reductions that might be associated with the use of OA compared to RA. For example, the smaller size of the OA catheter system facilitates radial as opposed to femoral access. Prior studies have shown reduced access site complications, treatment time, and lower overall treatment cost in patients treated with radial access [21, 22]. Including these aspects would have further increased the health-economic value proposition of OA therapy.
Conclusions
In summary, our model-based analysis suggests that orbital atherectomy treatment of patients with severely calcified coronary lesions, when compared to rotational atherectomy treatment, is associated with a lower target lesion revascularization rate and represents a cost-effective treatment strategy. Future confirmatory analyses are warranted.
Change history
27 October 2017
In the original publication of this article, in Abstract the 1-year mortality of OAS should be stated as 4.7 and not 5.5%.
References
Bourantas CV, Zhang YJ, Garg S, Iqbal J, Valgimigli M, Windecker S, et al. Prognostic implications of coronary calcification in patients with obstructive coronary artery disease treated by percutaneous coronary intervention: a patient-level pooled analysis of 7 contemporary stent trials. Heart. 2014;100:1158–64.
Mintz GS, Popma JJ, Pichard AD, Kent KM, Satler LF, Chuang YC, et al. Patterns of calcification in coronary artery disease. A statistical analysis of intravascular ultrasound and coronary angiography in 1155 lesions. Circulation. 1995;91:1959–65.
Moussa I, Di Mario C, Moses J, Reimers B, Di Francesco L, Martini G, et al. Coronary stenting after rotational atherectomy in calcified and complex lesions. Angiographic and clinical follow-up results. Circulation. 1997;96:128–36.
Genereux P, Madhavan MV, Mintz GS, Maehara A, Palmerini T, Lasalle L, et al. Ischemic outcomes after coronary intervention of calcified vessels in acute coronary syndromes. Pooled analysis from the HORIZONS-AMI (Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction) and ACUITY (Acute Catheterization and Urgent Intervention Triage Strategy) TRIALS. J Am Coll Cardiol. 2014;63:1845–54.
Jacobson KM, Hall Long K, McMurtry EK, Naessens JM, Rihal CS. The economic burden of complications during percutaneous coronary intervention. Qual Saf Health Care. 2007;16:154–9.
Jinnouchi H, Kuramitsu S, Shinozaki T, Kobayashi Y, Hiromasa T, Morinaga T, et al. Two-year clinical outcomes of newer-generation drug-eluting stent implantation following rotational atherectomy for heavily calcified lesions. Circ J. 2015;79:1938–43.
Nishida K, Kimura T, Kawai K, Miyano I, Nakaoka Y, Yamamoto S, et al. Comparison of outcomes using the sirolimus-eluting stent in calcified versus non-calcified native coronary lesions in patients on- versus not on-chronic hemodialysis (from the j-Cypher registry). Am J Cardiol. 2013;112:647–55.
Chambers JW, Diage T. Evaluation of the Diamondback 360 Coronary Orbital Atherectomy System for treating de novo, severely calcified lesions. Expert Rev Med Devices. 2014;11:457–66.
Genereux P, Lee AC, Kim CY, Lee M, Shlofmitz R, Moses JW, et al. Orbital atherectomy for treating de novo severely calcified coronary narrowing (1-year results from the pivotal ORBIT II trial). Am J Cardiol. 2015;115:1685–90.
Genereux P, Bettinger N, Redfors B, Lee AC, Kim CY, Lee MS, et al. Two-year outcomes after treatment of severely calcified coronary lesions with the orbital atherectomy system and the impact of stent types: insight from the ORBIT II trial. Catheter Cardiovasc Interv. 2016;88:369–77.
Cohen DJ, Reynolds MR. Interpreting the results of cost-effectiveness studies. J Am Coll Cardiol. 2008;52:2119–26.
Matsuo H, Watanabe S, Watanabe T, Warita S, Kojima T, Hirose T, et al. Prevention of no-reflow/slow-flow phenomenon during rotational atherectomy—a prospective randomized study comparing intracoronary continuous infusion of verapamil and nicorandil. Am Heart J. 2007;154(994):e1–6.
Shlofmitz RA, Saito S, Sharma SK, Stone GW. CRT-100.02 treatment of severely calcified coronary lesions with the coronary orbital atherectomy system micro crown: early results from the COAST trial. JACC: Cardiovasc Interv. 2016;9:S1.
Budoff MJ, Shaw LJ, Liu ST, Weinstein SR, Mosler TP, Tseng PH, et al. Long-term prognosis associated with coronary calcification: observations from a registry of 25,253 patients. J Am Coll Cardiol. 2007;49:1860–70.
Tamekiyo H, Hayashi Y, Toyofuku M, Ueda H, Sakuma T, Okimoto T, et al. Clinical outcomes of sirolimus-eluting stenting after rotational atherectomy. Circ J. 2009;73:2042–9.
Kyono H, Kozuma K, Shiratori Y, Maeno Y, Iino R, Takada K, et al. Angiographic and clinical outcomes of 100 consecutive severe calcified lesions requiring rotational atherectomy prior to sirolimus-eluting stent implantation in hemodialysis and non-hemodialysis patients. Cardiovasc Interv Ther. 2011;26:98–103.
Shiroiwa T, Sung YK, Fukuda T, Lang HC, Bae SC, Tsutani K. International survey on willingness-to-pay (WTP) for one additional QALY gained: what is the threshold of cost effectiveness? Health Econ. 2010;19:422–37.
Chambers J, Genereux P, Lee A, Lewin J, Young C, Crittendon J, et al. The potential cost-effectiveness of the Diamondback 360(R) Coronary Orbital Atherectomy System for treating de novo, severely calcified coronary lesions: an economic modeling approach. Ther Adv Cardiovasc Dis. 2016;10:74–85.
Garrison LP Jr, Zimmermann MR, Young CH, Crittendon J, Généreux P. Cost-effectiveness analysis of the orbital atherectomy system: Two-year follow-up. Cardiovasc Revasc Med. 2017;18(2):86–90.
Whitlow PL, Bass TA, Kipperman RM, Sharaf BL, Ho KK, Cutlip DE, et al. Results of the study to determine rotablator and transluminal angioplasty strategy (STRATAS). Am J Cardiol. 2001;87:699–705.
Rathod KS, Jones DA, Bromage DI, Gallagher SM, Rathod VS, Kennon S, et al. Radial primary percutaneous coronary intervention is independently associated with decreased long-term mortality in high-risk ST-elevation myocardial infarction patients. J Cardiovasc Med. 2015;16:170–7.
Bauer T, Hochadel M, Brachmann J, Schachinger V, Boekstegers P, Zrenner B, et al. Use and outcome of radial versus femoral approach for primary PCI in patients with acute ST elevation myocardial infarction without cardiogenic shock: results from the ALKK PCI registry. Catheter Cardiovasc Interv. 2015;86(Suppl 1):S8–14.
Kubota T, Ishikawa T, Nakano Y, Endoh A, Suzuki T, Sakamoto H, et al. Retrospective comparison of clinical and angiographic outcomes after sirolimus-eluting and bare-metal stent implantation in 312 consecutive, nonrandomized severely calcified lesions using a rotablator. Int Heart J. 2011;52:65–71.
Acknowledgements
Wing Tech Inc. (Drs. Geisler and Pietzsch) received fees from Cardiovascular Systems, Inc. for health-economic consulting services related to this analysis. Dr. Ikeno received consulting fees from Cardiovascular Systems, Inc. The authors would like to acknowledge Arisa Hasegawa and her colleagues at Medical Data Vision Co., Ltd. for conducting the underlying research of claims data from the Medical Data Vision (MDV) database. We are also indebted to Dr. Ichiro Michishita for providing additional perspective on current treatment patterns of calcified coronary artery lesions in the Japanese healthcare system.
Author information
Authors and Affiliations
Corresponding author
Electronic supplementary material
Below is the link to the electronic supplementary material.
Rights and permissions
Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
About this article
Cite this article
Pietzsch, J.B., Geisler, B.P. & Ikeno, F. Cost-effectiveness of orbital atherectomy compared to rotational atherectomy in treating patients with severely calcified coronary artery lesions in Japan. Cardiovasc Interv and Ther 33, 328–336 (2018). https://doi.org/10.1007/s12928-017-0488-3
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12928-017-0488-3