Abstract
Background
Alloplastic materials such as tantalum, gold plates and foils, hydroxyapatite blocks have been used for closure of oroantral fistula (OAF). However, these materials are not widely accepted in routine surgical closure of OAF due to cost, difficult handling, increased rate of infection, and exfoliation.
Purpose
To overcome the above drawbacks this study aimed to use titanium plates (0.3 mm) with transalveolar wiring fixation for closure of OAF.
Patients and Methods
Ten patients with OAFs who consented to undergo this trial were selected and treated under an outpatient basis in the Oral Surgery Department, Faculty of Dentistry, Mansoura University, Egypt.
Results
All OAFs were successfully treated with no eventful complications.
Conclusion
This study concludes that titanium plates with transalveolar wiring fixation is an excellent technique for closure of OAF. The high success rate with this technique warrants its use for closure of OAF.
Similar content being viewed by others
References
Borgonovo AE, Berardinelli FV, Favale M, Maiorana C (2012) Surgical options in oroantral fistula treatment. Open Dent J 6:94–98
Ehrl PA (1980) Oroantral communication. Epicritical study of 175 patients, with special concern to secondary operative closure. Int J Oral Surg 9(5):351–358
Yilmaz T, Suslu AE, Gursel B (2003) Treatment of oroantral fistula: experience with 27 cases. Am J Otolaryngol 24(4):221–223
Abuabara A, Cortez AL, Passeri LA, de Moraes M, Moreira RW (2006) Evaluation of different treatments for oroantral/oronasal communications. Int J Oral Maxillofac Surg 35(2):155–158
Hernando J, Gallego L, Junquera L, Villarreal P (2010) Oroantral communications. A retrospective analysis. Med Ora Patol Cir Buccal 15(3):499–503
Martensson G (1957) Operative method in fistulas to the maxillary sinus. Acta Otolaryngologica 48(3):253–4. Quoted from: Burić N, Jovanović G, Krasić D, Tijanić M, Burić M, Tarana S, Spasić M(2012) The use of absorbable polyglactin/polydioxanon implant (Ethisorb(®)) in non-surgical closure of oro-antral communication. J Craniomaxillofac Surg 40(1):71–7
Hanazawa Y, Itoh K, Mabashi T, Sato K (1995) Closure of oroantral communications using a pedicled buccal fat pad graft. J Oral Maxillofac Surg 53(7):771–775
Hori M, Tanaka H, Matsumoto M, Matsunaga S (1995) Application of the interseptal alveolotomy for closing the oroantral fistula. J Oral Maxillofac Surg 53(12):1392–1396
Awang MN (1988) Closure of oroantral fistula. Int J Oral Maxillofac Surg 17(2):110–115
Stewart K, Lazaw (1999) Surgical management of oroantral fistula: flap procedures. Op Tech Otolaryngol Head Neck Surg 10(2):148–152
Nkenke E, Radespiel-Tröger M, Wiltfang J, Schultze-Mosgau S, Winkler G, Neukam FW (2002) Morbidity of harvesting of retromolar bone grafts: a prospective study. Clin Oral Implants Res 13(5):514–521
Watzak G, Tepper G, Zechner W, Monov G, Busenlechner D, Watzek G (2005) Bony press-fit closure of oro-antral fistulas: a technique for pre-sinus lift repair and secondary closure. J Oral Maxillofac Surg 63(9):1288–1294
Peñarrocha-Diago M, García B, Gomez D, Balaguer J (2007) Zygomatic bone graft for oral-antral communication closure and implant placement. J Oral Implantol 33(5):305–309
Ahmed M, Askar N (2011) Combined bony closure of oroantral fistula and sinus lift with mandibular bone grafts for subsequent dental implant placement. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 111(4):8–14
Kansu L, Akman H, Uckan S (2010) Closure of oroantral fistula with the septal cartilage graft. Eur Arch Otorhinolaryngol 267(11):1805–1806
Isler SC, Demircan S, Cansiz E (2011) Closure of oroantral fistula using auricular cartilage: a new method to repair an oroantral fistula. Br J Oral Maxillofac Surg 49(8):86–87
McClung E, Chipps J (1951) Tantalum foil used in closing antro-oral fistulas. U S Armed Forces Med J 2(8):1183–6. Quoted from Visscher SH, van Minnen B, Bos RR(2010). Closure of Oroantral Communications: A Review of the Literature. J Oral Maxillofac Surg 68(6)1384–91
Goldman EH, Stratigos GT, Arthur AL (1969) Treatment of oroantral fistula by gold foil closure: report of case. J Oral Surg 27(11):875–877
Meyerhoff W, Christiansen T, Rontal E, Boerger W (1973) Gold foil closure of oroantral fistulas. Laryngoscope 83(6):940–944
Mainous EG, Hammer DD (1974) Surgical closure of oroantral fistula using the gold foil technique. J Oral Surg 32(7):528–530
Shapiro DN, Moss M (1972) Gold plate closure of oroantral fistulas. J Prosthet Dent 27(2):203–208
Smiler DG, Montemorano P (1972) The gold plate technique for closing oro-antral openings. J South Calif Dent Assoc 40(2):122–128
Steiner M, Gould AR, Madion DC, Abraham MS, Loeser JG (2008) Metal plates and foils for closure of oroantral fistulae. J Oral Maxillofac Surg 66(7):1551–1555
Al Sibahi A, Shanoon A (1982) The use of soft polymethylmethacrylate in the closure of oro-antral fistula. J Oral Maxillofac Surg 40(3):165–166
Zide MF, Karas ND (1992) Hydroxylapatite block closure of oroantral fistulas: report of cases. J Oral Maxillofac Surg 50(1):71–75
Ogunsalu C (2005) A new surgical management for oro-antral communication: the resorbable guided tissue regeneration membrane—Bone substitute sandwich technique. West Indian Med J 54(4):261–263
Gonty AA (1997) Diagnosis and management of sinus disease. In: Peterson LJ, Indresano T, Marciani R, Roser S (eds) Principles of oral and maxillofacial surgery. Lippincott-Raven, Philadelphia, pp 223–266
Elias CN, Gravina PA, Silva Filho CE, Nascente PA (2012) Preparation of bioactive titanium surfaces via fluoride and fibronectin retention: Int J Biomater 2012:290179. doi: 10.1155/2012/290179
Ohkubo C, Watanabe I, Ford JP, Nakajima H, Hosoi T, Okabe T (2000) The machinability of cast titanium and Ti6Al4 V. Biomaterials 21(4):421–428
Punwutikorn J, Waikakul A, Pairuchvej V (1994) Clinically significant oroantral communications—A study of incidence and site. Int J Oral Maxillofac Surg 23(1):19–21
del Rey-Santamaría M, Valmaseda Castellón E, Berini Aytés L, Gay Escoda C (2006) Incidence of oral sinus communications in 389 upper third molar extraction. Med Oral Patol Oral Cir Bucal 11(4):334–338
Rehrmann A (1936) Eine methode zur schliessung von kieferhohlen perforationen. Dtsch Zahnartl Wochenzeitschr 39:1136. Quoted from Burić N, Jovanović G, Krasić D, Tijanić M, Burić M, Tarana S, Spasić M (2012) The use of absorbable polyglactin/polydioxanon implant (Ethisorb(®)) in non-surgical closure of oro-antral communication. J Craniomaxillofac Surg 40(1):71–7
Killey HC, Kay LW (1972) Observations based on the surgical closure of 362 oro-antral fistulas. Int Surg 57(7):545–549
Martín-Granizo R, Naval L, Costas A, Goizueta C, Rodriguez F, Monje F et al (1997) Use of buccal fat pad to repair intraoral defects: review of 30 cases. Br J Oral Maxillofac Surg 35(2):81–84
Nezafati S, Vafaii A, Ghojazadeh M (2012) Comparison of pedicled buccal fat pad flap with buccal flap for closure of oro-antral communication. Int J Oral Maxillofac Surg 41(5):624–628
Ashley REA (1939) A method of closing antroalveolar fistulae. Ann Otol Rhinol Laryngol 48: 632. Quoted from Lee JJ, Kok SH, Chang HH, Yang PJ, Hahn LJ, Kuo YS (2002) Repair of oroantral communications in the third molar region by random palatal flap. Int J Oral Maxillofac Surg 31(6): 677–80
Franco-Carro B, Barona-Dorado C, Martínez-González MJ, Rubio-Alonso LJ, Martínez-González JM (2011) Meta-analytic study on the frequency and treatment of oral antral communications. Med Oral Patol Oral Cir Bucal 16(5):682–687
Erdoğan O, Esen E, Ustün Y (2005) Bony palatal necrosis in a diabetic patient secondary to palatal rotational flap. J Diabetes Complications 19(6):364–367
Visscher SH, van Minnen B, Bos RR (2010) Closure of oroantral communications: a review of the literature. J Oral Maxillofac Surg 68(6):1384–1391
Ravnholt G (1989) Corrosion current and pH rise around titanium coupled to dental alloys. Scand J Dent Res 96(5):466–472
Ravnholt G, Jensen J (1991) Corrosion investigation of two materials for implant supraconstructions coupled to a titanium implant. Scand J Dent Res 99(2):181–186
von Wowern N (1973) Correlation between the development of an oroantral fistula and the size of the corresponding bony defect. J Oral Surg 31(2):98–102
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Ahmed, W.M.S. Closure of Oroantral Fistula Using Titanium Plate with Transalveolar Wiring. J. Maxillofac. Oral Surg. 14, 121–125 (2015). https://doi.org/10.1007/s12663-013-0584-6
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12663-013-0584-6