Sevoflurane is a widely used volatile anesthetic for anesthesia maintenance, but minimum fresh gas flows (FGFs) are recommended because of concerns of nephrotoxicity when used under low FGF conditions.1 While nephrotoxicity of inhaled anesthetics is well known with older agents such as methoxyflurane,2 such effects are largely theoretical with sevoflurane, with no definitive evidence regarding its nephrotoxicity. The two causes of concern regarding sevoflurane-induced nephrotoxicity are the relatively higher inorganic fluoride load on the kidneys secondary to its in vivo metabolism, and the ex vivo generation of compound A (CpdA), a substance generated following the reaction of sevoflurane with high alkali-containing carbon dioxide (CO2) absorbents,3 which is nephrotoxic in rodents. These concerns are presumed to be higher when sevoflurane is used in a circle ventilation circuit where a low FGF rate may result in accumulation of potentially toxic metabolites within the circuit.3

As a result, manufacturers have recommended various minimum FGF1 rates with subsequent implications to the overall cost and the environmental footprint of anesthetic gases.4,5,6 The product monograph for sevoflurane is different in different countries. In product monographs with FGF recommendations, these are tied to the presumed nephrotoxic potential of CpdA and not to fluoride levels or potential damage to organs other than the kidneys. Countries such as Germany, the United Kingdom, Ireland, or France, among others, have no defined minimum FGF recommendation.4,7,8,9 An FGF of 2 L·min−1, as is recommended in Canada, can increase the consumption and thus the cost and the environmental pollution from sevoflurane by a factor of four compared with use of minimal FGFs.

A recent systematic review of six studies on sevoflurane and isoflurane in patients with normal renal function did not find any differences in postoperative renal function between the two agents.10 Although several studies have investigated the use of sevoflurane on subsequent postoperative renal function over the past 30 years, this evidence has not yet been comprehensively reviewed. Hence, it is important to comprehensively review any association between the use of sevoflurane and subsequent renal function, especially factoring in the use of various FGFs, absorbents, and pre-existing renal dysfunction.

The primary aim of this study was to review the evidence of the impact of sevoflurane on postoperative renal function compared with alternative anesthetic maintenance agents deemed safe for the kidneys. The secondary aims of this study were to review the effect of sevoflurane on renal function under different FGFs, pre-existing renal dysfunction, and different absorbents, as well as whether different FGFs and exposure durations have an effect on peak fluoride or CpdA levels.

Methods

Literature review

We followed the Cochrane handbook on systematic review of interventions for the conduct of the review,11 and we reported in accordance with the statement on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) (Fig. 1).12 Our search strategy covered the date of inception for each database to our final search and date of inclusion (23 April 2020). The databases included MEDLINE OVID (1946–present), Pubmed (1966–present), EMBASE (1947–present), the Cochrane Library—which included the Cochrane Database of Systematic Reviews (1995–present) and the Cochrane Central Register of Controlled Trials (CENTRAL)—CINAHL (1961–present), and Web of Science (1900–present). We did not apply any additional chronological parameters to our search. Additional search techniques included hand-searching the reference lists for further relevant studies and Google Scholar for grey literature. Key search terms included “sevoflurane”, “nephrotoxicity”, “renal function test” (RFT), “compound-A”, “fluoride”, “absorbent”, “low-flow”, “high-flow”, “blood urea nitrogen” (BUN), “creatinine”, and “creatinine clearance” (CCR). We did not exclude any languages because translation services were available in the university. The full search strategy is described in the eAppendix, available as Electronic Supplementary Material (ESM). A reference list was also created based on all articles the authors were able to discover independently and was then examined to ensure that all reference articles published by 23 April 2020 were retrieved in the searches. All titles and abstracts were independently screened by two authors (T.O. and R.S.) and only potentially relevant randomized-controlled trials (RCTs) were selected and reviewed by the two authors independently. Any disagreements were resolved by mutual discussion.

Fig. 1
figure 1

PRISMA flow diagram

Study selection

Only human RCTs reporting on the use of sevoflurane vs another agent used for anesthesia maintenance, with subsequent measurement of renal function parameters, were included in this review. We excluded RCTs that did not examine renal function following exposure to sevoflurane or did not use sevoflurane for anesthesia maintenance. We included trials on patients with stable preoperative renal dysfunction as we planned to perform subgroup analysis to detect any differences between patients with normal vs impaired renal function following exposure to sevoflurane.

We also collected any data on tubular function as assessed by urinary N-acetyl glucosamine (U-NAG), kidney injury molecule-1, fatty-acid-binding proteins (FABP-H), U-NAG/creatinine ratio, glutathione S-transferase, and α and ß macroglobulin. Data were also reviewed pertaining to glomerular function as assessed by markers like cystatin-C or markers for both glomerular and tubular function such as urinary 24-hr albumin and urinary 24-hr protein. We further included specific gravity, pH, and osmolality of urine as outcome measures. To look at the fluoride and CpdA load on the kidneys following sevoflurane use, all studies reporting these parameters with sevoflurane use were included in the analysis.

Data extraction and primary endpoints

Two investigators (K.N. and T.S.) independently reviewed and appraised each study prior to extracting the data on a standard data collection sheet. Any discrepancies between these two reviewers were resolved by discussion with a third investigator (R.S.). The time points of data collection were preoperative baseline values, early (four to six postoperative hours), and 24 and 48 postoperative hours with the 24-hr measurements for BUN, creatinine, and CCR being the primary endpoints. In trials not reporting the outcomes as mean (standard deviation [SD]) or not reporting at the pre-specified time points, the corresponding authors were contacted up to three times via email. When the measurements were reported as median (confidence interval [CI]/interquartile range [IQR]/standard error [SE]) or as variance, these values were converted to mean (SD) based on previously published conversion formulas.13 All the values were converted to standard units of measurement before conducting statistical analysis. We followed the Cochrane Handbook for Systematic Reviews of Interventions recommendations when handling RCTs with more than two study arms by splitting the “shared” group into two or more groups with smaller sample sizes, and included two or more independent comparisons.11 If mean (SD) values could not be directly obtained either from the published manuscripts or from correspondence, the values were deduced from the figures—first manually and then reconfirmed using the Adobe Acrobat measurement tool and plot digitizer software (http://plotdigitizer.sourceforge.net/).

Risk of bias assessment

The quality of studies was appraised by the Cochrane Collaboration risk of bias instrument (version 5.0.1), which includes components to look for selection bias (based on random sequence generation and allocation concealment), performance bias (masking of both participants and investigators), detection bias (masking of evaluators), attrition bias (incomplete outcome data), reporting bias (selective outcome reporting), and other types of bias. Each component of individual RCTs was judged to be of low, unclear, or high risk of bias. When there were at least ten studies for meta-analysis, we assessed publication bias by visual assessment of funnel plot asymmetry. We did not quantify the degree of publication bias.

Statistical analysis

Statistical analysis was performed using Review Manager (RevMan; version 5.3. Copenhagen: The Nordic Cochrane Centre, The Cochrane Collaboration, 2014). Patients who received sevoflurane were allocated to the intervention group while patients receiving any anesthetic agent other than sevoflurane were considered as “alternative anesthetic” groups. Given our inclusion of a variety of different surgical populations and comparators, we expected clinical heterogeneity, so the meta-analysis was performed using the Mantel–Haenszel random-effects model. As all of our outcomes were continuous variables, the standardized mean difference (SMD) was calculated for each outcome and analyzed using forest plots for the magnitude and direction of effect. An SMD of ≤ 0.2 was considered small, an SMD of 0.5 was considered medium, and an SMD > 0.8 was considered large.14 The heterogeneity of outcomes across trials was assessed using the I2 statistic. We considered an I2 of > 50% to indicate significant heterogeneity and planned to address it by further exploration using subgroup analyses. Additionally, between-trial heterogeneity was planned as a sensitivity measure to see the effect of individual trials.

A priori subgroup analysis was planned to look for associations between the use of sevoflurane and renal function with respect to FGF, duration of anesthesia, type of absorbent used, and the presence or absence of prior renal impairment. The parameters of FGF and duration of anesthesia were dichotomized with FGF categorized as either low-flow anesthesia (LFA) (≤ 1 L FGF) or high-flow anesthesia (HFA) (≥ 1 L FGF) while the duration of anesthesia was categorized as ≤ three hours or ≥ three hours. Further exploration of heterogeneity was planned via meta-regression if there were significant differences in outcomes between sevoflurane and alternative anesthetics or if significant heterogeneity was present. Meta-regression models with plots were generated using OpenMeta[Analyst] software (http://www.cebm.brown.edu/openmeta/) to explore the use of sevoflurane and subsequent fluoride and CpdA levels and their association with the FGF and the duration of exposure. We did not perform meta-analysis for tubular function tests; these outcomes were summarized descriptively in the review.

Quality of evidence

We rated the confidence in the estimate of effects based on a scoring system that, apart from the risk of bias, includes assessments for inconsistency, indirectness, imprecision, and publication bias. We utilized the GRADE-Pro tool to score the individual components and based on the above assessments, we classified the strength of evidence as strong, moderate, low, or very low quality.

Patient and public involvement

Patients and/or the public were not involved in the creation of this systematic review and meta-analysis as the format did not lend itself to outside participation.

Results

A total of 3,766 records were identified through database searches and cross referencing for the initial screening. After review of the abstracts, 3,580 studies were excluded for various reasons, and 186 RCTs were considered for full-text assessment. Of these 186 RCTs, a further 131 articles were excluded from quantitative synthesis (125 articles were excluded as they did not measure renal parameters as a part of their outcomes and six articles were excluded as we could not retrieve the full texts despite multiple attempts).15,16,17,18,19,20 Twelve other studies were also excluded21,22,23,24,25,26,27,28,29,30,31,32 (Fig. 1; PRISMA diagram) and data were extracted from 41 RCTs.33,34,35,36,37,38,39,40,41,42,43,44,45,46,47,48,49,50,51,52,53,54,55,56,57,58,59,60,61,62,63,64,65,66,67,68,69,70,71,72,73 There were no disagreements between the authors regarding study selection, but additional articles were retrieved by a single reviewer (R.S.) through cross referencing. Data extracted by the two reviewers (K.N. and T.S.) were crosschecked for accuracy by another reviewer (R.S.) and any discrepancies in data collection or conversion were resolved mutually. Three studies were translated into English.41,53,66

Study characteristics

Characteristics of the included studies and the assessed outcomes are summarized in Table 1. The outcomes assessed in these studies other than those outlined in Table 1 include urinary albumin,53 urinary alpha macroglobulin,34,58 glutathione S-transferases-alpha,34,50 and serum osmolality,42,61,67,73 There was significant variability among the included trials in terms of patient population, type of surgery, presence of prior renal impairment, FGF, duration of exposure, and the use of CO2 absorbents. Conversions to mg·dL−1 were done for creatinine24,34,55,61,64,68 and BUN24,55,61,64,67,70 from non-SI units of measurements while conversions to mean (SD) for central tendency and dispersions were needed in four more studies.57,64,68,70 Creatinine values were extrapolated from graphical data in seven studies,49,51,54,56,69,71,72 BUN in eight studies,43,49,51,54,56,69,71,72 CCR in eight studies,39,40,43,49,53,56,60,68 and peak serum fluoride in 18 studies.35,36,39,40,42,43,48,49,50,55,58,59,60,61,65,68,69,73

Table 1 Randomized controlled studies and characteristics

Risk of bias assessment

The risk of bias rating for the included trials is given in Fig. 2 and the risk of bias is summarized in Fig. 3. All the included trials were RCTs. All but four studies43,45,58,68 addressed random sequence generation, nine studies adequately addressed allocation concealment,34,37,39,52,56,57,64,66,70 two trials explicitly stated blinding procedures,57,71 ten studies adequately addressed detection bias,34,44,52,55,56,57,63,64,71,72 and 29 trials accounted for all patients in the trial.34,38,39,40,41,43,44,45,47,48,49,50,51,52,53,55,57,58,59,60,62,63,64,65,67,69,70,71,73

Fig. 2
figure 2

Risk of bias rating for the included trials

Fig. 3
figure 3

Risk of bias graph: authors’ judgements about each risk of bias item for included studies

Primary outcome

The primary outcome of BUN, creatinine, and CCR to assess the renal function at 24 postoperative hours were not impaired following the use of sevoflurane vs alternative anesthetics. In 24 studies (n = 2,024), the effect of sevoflurane (n = 1,015) on serum creatinine was compared with that in the alternative anesthetic group (n = 1,009) as noted by an SMD of 0.04 mg·dL−1 (95% CI, −0.06 to 0.13) (Fig. 4). In 21 studies (n = 1,529) evaluating the effect of sevoflurane (n = 731) vs alternative anesthetic (n = 798) on BUN, no differences were noted (SMD, 0.06; 95% CI, −0.04 to 0.16) (Fig. 5). A total of 12 studies (n = 728) evaluated the effect of sevoflurane (n = 385) vs alternative anesthetic (n = 343) on CCR and showed no differences between the groups (SMD, 0.14; 95% CI, −0.09 to 0.37) (Fig. 6).

Fig. 4
figure 4

Forest plot showing the overall effect of sevoflurane vs an alternative anesthetic agent on serum creatinine measured at 24 postoperative hours

Fig. 5
figure 5

Forest plot showing the overall effect of sevoflurane vs an alternative anesthetic agent on blood urea nitrogen (BUN) measured at 24 postoperative hours

Fig. 6
figure 6

Forest plot showing the overall effect of sevoflurane vs an alternative anesthetic agent on creatinine clearance (CCR) measured at 24 postoperative hours

Subgroup analysis for the primary outcome

Subgroup analysis was performed for the primary outcome variables to detect any effect of sevoflurane under different FGF, types of absorbents, duration of anesthetic exposure, and the presence of stable renal dysfunction on renal function parameters (Figs 716). Although there seemed to be a trend for lower creatinine and BUN concentrations in the alternative anesthetic group in patients with pre-existing renal impairment, the pooled estimate of effect for the use of sevoflurane on serum creatinine crossed the line of null effect (Figs 8 and 11).

Fig. 7
figure 7

Subgroup analysis showing the effect of sevoflurane vs an alternate anesthetic agent on serum creatinine measured at 24 postoperative hours when delivered at low fresh-gas flow (FGF) (≤ 1 L) or high FGF (> 1 L)

Fig. 8
figure 8

Subgroup analysis showing the effect of sevoflurane vs an alternate anesthetic agent on serum creatinine measured at 24 postoperative hours when delivered to patients with or without prior stable renal dysfunction

Fig. 9
figure 9

Subgroup analysis showing the effect of sevoflurane vs an alternate anesthetic agent on the serum creatinine measured at 24 postoperative hours when used in conjunction with various absorbents

Fig. 10
figure 10

Subgroup analysis showing the effect of sevoflurane vs an alternate anesthetic agent on the serum creatinine measured at 24 postoperative hours when the duration of exposure is dichotomized to ≤ or > three hours

Fig. 11
figure 11

Subgroup analysis showing the effect of sevoflurane vs an alternate anesthetic agent on blood urea nitrogen (BUN) measured at 24 postoperative hours when delivered to patients with or without prior stable renal dysfunction

Fig. 12
figure 12

Subgroup analysis showing the effect of sevoflurane vs an alternate anesthetic agent on blood urea nitrogen (BUN) measured at 24 postoperative hours when delivered at low fresh-gas flow (≤ 1 L FGF) or high fresh-gas flow (> 1 L FGF)

Fig. 13
figure 13

Subgroup analysis showing the effect of sevoflurane vs an alternate anesthetic agent on the blood urea nitrogen (BUN) measured at 24 postoperative hours when used in conjunction with various absorbents

Fig. 14
figure 14

Subgroup analysis showing the effect of sevoflurane vs an alternate anesthetic agent on the blood urea nitrogen (BUN) measured at 24 postoperative hours when the duration of exposure is dichotomized to ≤ or > three hours

Fig. 15
figure 15

Subgroup analysis showing the effect of sevoflurane vs an alternate anesthetic agent on creatinine clearance (CCR) measured at 24 postoperative hours when delivered at low fresh-gas flow (≤ 1 L [FGF]) or high fresh-gas flow (> 1 L FGF)

Fig. 16
figure 16

Subgroup analysis showing the effect of sevoflurane vs an alternate anesthetic agent on the creatinine clearance (CCR) measured at 24 postoperative hours when used in conjunction with various absorbents

The FGF is thought to be important during sevoflurane use. The subgroup analysis with the FGF dichotomized as ≤ 1 L FGF vs > 1 L FGF revealed that the pooled estimate crossed the line of null effect, denoting no significant benefit of sevoflurane or the alternative anesthetic on the 24-hr measurements of CCR (12 studies with 427 subjects; six studies employing ≤ 1 L FGF; and six studies employing >1 L FGF), creatinine (19 studies with 1,202 subjects; nine studies employing ≤ 1 L FGF; and ten studies employing >1 L FGF), or the BUN concentration (12 studies with 1,232 subjects; 11 studies employing ≤ 1 L FGF; and nine studies employing >1 L FGF) (Figs 7, 12, and 15). A similar null effect was observed on subgroup analysis for the effect of duration of exposure (≤ three hours vs > three hours) and the use of type of absorbents on subsequent measurement of CCR, creatinine, or BUN values measured at 24 postoperative hours (Figs 9, 10, 13, 14, and 16).

Subgroup analysis for CCR was performed only for FGF and absorbent type as there was an inadequate number of studies looking at CCR after prolonged anesthetic duration. The CCR values were higher in the sevoflurane group with the use of soda lime while this was not the case with baralyme (Figs 15 and 16).

Renal function tests at other time points

Renal function tests of creatinine, BUN, and CCR did not reveal differences between sevoflurane or alternative anesthetics either at early postoperative or 48 postoperative hour measurements. Postoperative creatinine concentration (mg·dL−1) was reported in eight studies. There were no differences between sevoflurane and alternative anesthetics (SMD, 0.10; 95% CI, −0.23 to 0.43) (ESM eFigs 1 and 2). At 48 postoperative hours, a pooled estimate of serum creatinine from 16 studies (n = 1,510) also showed no difference (SMD, 0.08; 95% CI, −0.03 to 0.18). The BUN values (mg·dL−1) did not differ with sevoflurane in the early postoperative period (SMD, −0.15; 95% CI, −0.72 to 0.42) or at 48 postoperative hours vs alternative anesthetic (SMD, 0.07; 95% CI, −0.04 to 0.18) (ESM eFigs 3 and 4). Findings for CCR were similar (ESM eFigs 5 and 6). Higher baseline concentrations of BUN and creatinine were noted for patients with pre-existing stable renal dysfunction, but there was no difference following sevoflurane anesthesia. Unusually low values of CCR were reported in the postoperative measurements in one study,40 more so in the alternative anesthetic group than the sevoflurane group and this could be related to the elderly population included in the study or the effect of epidural analgesia, although the 24-hr CCR values showed no difference between sevoflurane and alternative anesthetics.

Fluoride levels

Twenty-three studies selected in our review evaluated the effect of sevoflurane on free fluoride load on the kidneys.35,36,37,39,40,41,42,43,48,49,55,56,58,59,60,61,62,65,66,67,68,69,73 In trials comparing sevoflurane with other halogenated agents, sevoflurane was associated with a higher fluoride load (µmol·L−1) at 24 postoperative hours in 15 studies (SMD, 6.16; 95% CI, 4.42 to 7.90) (ESM eFig. 7) and at 48 hr in nine studies (ESM eFig. 8) (SMD, 4.35; 95% CI, 1.75 to 6.96).

Peak plasma fluoride and peak CpdA

The pooled estimate of peak serum fluoride (mean) following sevoflurane from all the studies was 35.08 (95% CI, 31.52 to 38.64) µmol·L−1 (ESM eFig. 9) and was higher compared with other halogenated agents (Fig. 17). The effect of FGF and the duration of exposure on peak fluoride levels was measured using meta-regression and presented as bubble plot graphs. Fluoride load was higher with increasing exposure (duration being the covariate) (ESM eFig. 10) but not with an increasing FGF (FGF being the covariate) (ESM eFig. 11).

Fig. 17
figure 17

Forest plot showing pooled estimate of peak plasma fluoride level for sevoflurane vs an alternative inhaled anesthetic agent

The effects of sevoflurane on maximum CpdA levels were assessed in ten studies.31,44,45,47,49,50,56,62,69,72 The pooled mean peak CpdA levels was 25.90 (95% CI, 21.46 to 30.35) as assessed across a variety of durations and FGF (ESM eFig. 12). Higher FGF was associated with lower CpdA level (ESM eFig. 13) but no association was noted with duration of exposure (ESM eFig. 14).

Tests of tubular function

Despite inconsistencies in the units of measurements, all studies were consistent in noting a lack of significant derangement in tubular function with the use of sevoflurane compared with alternative anesthetics (Table 2). Only one study noted sustained effects on glomerular, proximal, and distal tubular function after prolonged exposure to sevoflurane but not with desflurane.72 There was no summation of these measures in this study, but the tubular and glomerular function were documented on a case by case basis.

Table 2 Tubular function

Summary of findings

Based on the cumulative strength of evidence assessed as per the GRADE recommendations, we can conclude with low to moderate certainty that sevoflurane use did not disturb renal function measures of creatinine, BUN, and CCR (Table 3). We can conclude with certainty that peak and 24-hr fluoride levels are higher when sevoflurane is used compared with when other volatile anesthetics are used.

Table 3 Summary of evidence

Discussion

Our systematic review and meta-analysis of randomized-controlled studies showed that variables used to assess renal function (i.e., creatinine, CCR, and BUN) at 24 postoperative hours did not differ significantly following the use of sevoflurane compared with alternative anesthetics. Although the quality of evidence is moderate, sevoflurane usage assessed in subgroups utilizing LFA, in patients with pre-existing renal impairment, and across a wide variety of CO2 absorbents showed comparable renal function with that of alternative anesthetics. This has important economic and environmental consequences as well as implications for clinical practice.

Sevoflurane was first approved for human use in Japan in 199074 and has shown significant benefits over other volatile anesthetics.75 Uncertainty has remained in regard to potential nephrotoxicity in humans. The main concerns have been the higher fluoride load and CpdA generation, both of which have been associated with direct nephrotoxicity. Also of concern have been factors like FGF, in particular LFA, pre-existing renal impairment, duration of sevoflurane anesthesia, and the choice of absorbent.

Prior renal dysfunction may be concerning to anesthesiologists if sevoflurane was to impact renal function. Our review identified a total of three studies (n = 174) that were conducted in patients with preoperative stable renal dysfunction46,67,69 and two studies that were conducted in patients who had been exposed to nephrotoxic agents33,44 None of these studies showed any significant impairment in RFT results following sevoflurane use compared with alternative anesthetics.

A second concern with the use of sevoflurane is its interaction with CO2 absorbents, which has driven the increased FGF recommendations by the manufacturers. Sevoflurane is known to interact with alkali-containing (KOH or NaOH) CO2 absorbents such as soda lime or baralyme, resulting in alkaline degeneration and the subsequent formation of CpdA. The effects of CpdA on subsequent renal dysfunction were brought into focus by animal studies and one trial in healthy volunteers from one group of researchers.72,76,77 This subsequently prompted public health departments worldwide to recommend a minimum FGF to diminish the accumulation of CpdA in the breathing circuits and consequently in the patients. Nevertheless, a lack of nephrotoxicity despite higher levels of exposure to CpdA has been shown in clinical studies.45,50,78,79 The generation of CpdA and its subsequent accumulation may be related to a variety of factors such as the type and humidity of the absorbent, temperature, CO2 production, and FGFs.80,81 While CpdA exposure has shown to be cumulative with increasing duration of exposure in some studies,1,77,82 our meta-regression plots with duration of anesthetic as the covariate did not find such an association, in agreement with other studies.83,84

Peak plasma fluoride was elevated with sevoflurane use compared with the use of other halogenated agents such as isoflurane, desflurane, or enflurane. The mean pooled peak plasma fluoride after sevoflurane usage was 35.08 (95% CI, 31.52 to 38.64), but some studies showed peak levels > 50 µM.42,43,48,49,58 The threshold for renal toxicity secondary to methoxyflurane anesthesia was accepted to be a plasma fluoride level of 50 µM.2 An important distinction between methoxyflurane and sevoflurane based on experimental and clinical evidence is that methoxyflurane undergoes not only extensive metabolism (70%) but also intra-renal metabolism, which could have contributed to nephrotoxicity. While methoxyflurane-associated nephrotoxicity ranged from transient derangements in RFT results (such as creatinine or BUN) to fulminant vasopressin-resistant high-output renal failure, our review did not note any derangements in RFT results or incidences of overt renal failure with the sevoflurane use compared with the use of alternative anesthetics.

Increasing FGF has been thought to reduce the risk of accumulating CpdA, which is based on in vitro studies showing a decreasing CpdA concentration with an increasing FGF,1 and this finding was reconfirmed in our meta-regression plots of CpdA and FGF. While increasing the FGF is thought to reduce the circuit concentrations of CpdA, whether such increases in FGF actually prevent CpdA-induced renal dysfunction has long been speculated. Our review identified 12 studies, including the ones with patients at risk for renal injury,33,44,46,69 that evaluated whether a low FGF sevoflurane anesthetic is injurious to kidneys. None of the studies showed any increase in BUN, CCR, or creatinine following sevoflurane use compared with use of alternative anesthetics.33,37,42,43,45,50,62,63,69,71 A positive correlation has been suggested between the dosage of sevoflurane and the subsequent plasma fluoride levels85 but our meta-regression plots failed to note an association between increasing FGF or duration of exposure with subsequent plasma inorganic fluoride levels. This could be due to the saturable kinetics of sevoflurane metabolism, but further studies are needed to explore this. The fluoride load depends on the hepatic metabolism of sevoflurane, which is much higher than that of other currently used halogenated agents and hence is independent of the sevoflurane load on the body in terms of FGF.

The rationale and the evidence for the lack of association between CpdA and nephrotoxicity in humans has been known for quite some time.85 There is a species difference in the occurrence of CpdA-mediated nephrotoxicity and is directly related to the ß-lyase activity of the tubular cells. A high activity of this enzyme is specific to rodents. Since non-rodents do not have a high ß-lyase activity, the nephrotoxicity of CpdA is not significant as evidenced by animal and human studies on prolonged exposure to CpdA. A minimum FGF recommendation in product monographs to curb CpdA levels is unnecessary. With the introduction of newer alkali-free non-reactive absorbents such as litholyme and amsorb, minimally reactive absorbents containing soda lime, and with the end of the production of baralyme, the issue of CpdA generation is antiquated in current practice.86,87

Based on the outcome of this meta-analysis, we conclude that sevoflurane does not contribute more to nephrotoxicity in humans than alternative anesthetics do. Often mistaken to generally be about nephrotoxicity or other organ toxicity, FGF recommendations for sevoflurane are only tied to CpdA production. While many European countries eliminated FGF recommendations for sevoflurane in the late 1990s, other countries and healthcare systems still have FGF recommendations in place today. This has significantly increased wasteful spending on anesthetic agents but more importantly, has increased the atmospheric release of a very potent greenhouse gas.6 It is very hard to change a product monograph and there is no financial benefit for drug manufacturers to apply to regulatory bodies to do so. More important will be for anesthesia societies to issue practice advisories based on available evidence, incorporating the availability of non-reactive absorbents, and to refute existing FGF recommendations for sevoflurane. This is a patient safety issue in that there is a false sense of unsafe practice when a physician runs a low FGF sevoflurane anesthetic. Practice advisories will also reduce fear of litigation.

Limitations

There are certain limitations to our review. Our review did not identify studies with exposure beyond eight hours, so the long-term safety of sevoflurane may need further study. We also cannot comment on the safety of sevoflurane on other organ systems as this was beyond the purview of our review. We did not look at the effect of hepatic enzyme induction as seen in patients with alcohol abuse, or intake of certain medications (barbiturates, phenytoin), and we excluded certain vulnerable patient populations such as patients with cirrhosis and patients undergoing organ transplant in whom the metabolism of sevoflurane may be altered; further studies are needed to investigate these factors. The tubular function tests conducted across various studies were inconsistent in the timepoints of reporting and the units of measurement. Future studies should focus on utilizing consistent units of measurement when reporting these outcome measures for better comparability.

Our rating of the study quality was low to medium, as most studies had problems with physician- and allocation blinding. Conducting studies while ensuring blinding of the performer can be difficult when utilizing inhaled anesthetic agents and would not have affected the laboratory measurements used in this analysis. Because of the inherent difficulty in blinding the anesthesiologist to which vapor is being used, it is also unlikely that blinded studies (i.e., with low risk of bias) can be conducted in the future or that these would yield different outcome measurements.

We extrapolated median (CI/IQR/SE) values into mean (SD) values for many data points of included studies using approved meta-analytical methods. These extrapolated values can vary depending on how the conversions were made, and a different method of estimation may have potentially affected our conclusions. Future studies performed in low FGF settings with different newer absorbents may affect our conclusions and more studies or population-based safety data are needed to definitively conclude our findings. Although we performed a thorough search, there is a possibility of missed studies. In addition, we could not retrieve the full text of six studies despite multiple attempts.

Conclusions

Based on the data extracted from 41 RCTs, sevoflurane usage did not increase renal dysfunction compared with other agents used for anesthesia maintenance. This was true when sevoflurane was administered with low FGF, in patients with stable renal dysfunction, with different absorbents, and at varying duration of exposure. Sevoflurane results in higher fluoride load and accumulation of CpdA with no adverse effects on renal function. While the formation of inorganic fluoride had no relationship to FGF or duration of exposure, the formation of CpdA showed an inverse relationship to FGF. Minimum FGF recommendations for sevoflurane anesthesia are not supported by our analysis and should be reconsidered.