Use of inertial sensors as devices for upper limb motor monitoring exercises for motor rehabilitation

  • Original Paper
  • Published:
Health and Technology Aims and scope Submit manuscript

Abstract

This paper presents the development of a system that uses inertial sensors, wireless transceivers and virtual models to monitor the exercises of motor rehabilitation of the upper limbs based on Kabat’s method. This method involves performing rehabilitation complex exercises that cannot be easily reproduced by the patient, requiring permanent assistance of a qualified professional. However, it is very expensive to have a professional expert assisting the patient throughout the treatment. Therefore, the development of technologies to monitor this type of exercise is necessary. The Kabat’s method has several applications, e.g. in motor rehabilitation of stroke patients. Stroke is considered the second most common cardiovascular disorder and affects about 9.6 million people in Europe alone, and an estimated 6 million people worldwide die from this disorder. Also, the natural aging process increases the number of strokes, and the demand for healthcare and motor rehabilitation services. To minimize this problem, we propose an experimental system consisting of inertial sensors, wireless transceivers and virtual models according to the models of Denavit & Hartenberg and Euler Angles & Tait Bryan. Through inertial sensors, this system can characterize the movement performed by the patient, compare it with a predefined motion and then indicate if the motor system performed the correct movement. The patients monitor their own movements and the movement pattern (correct movement). All movements are stored in a database allowing continuous checking by a qualified professional. Several experimental tests have shown that the average system error was 0.97°, which is suitable to the proposed system.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11

Similar content being viewed by others

References

  1. Côrrea D, Babinot A. Accelerometry for the motion analysis of the lateral plane of the human body during gait. Health Technol. 2011;1(1):35–46.

    Article  Google Scholar 

  2. Armstrong WJ, McGregor SJ, Yaggie JA, Bailey JJ, Johnson SM, Goin AM, et al. Reliability of mechanomyography and triaxial accelerometry in the assessment of balance. J Electromyogr Kinesiol. 2010;20:726–31.

    Article  Google Scholar 

  3. Moreau M, Sibert S, Buerket A, Schlecht E. Use of a tri-axial accelerometer for automated recording and classification of goat’s grazing behavior. Appl Anim Behav Sci. 2009;119:158–70.

    Article  Google Scholar 

  4. Robert B, White BJ, Renter DG, Larson RL. Evaluation of three-dimensional accelerometers to monitor and classify behavior patterns in cattle. Comput Electron Agric. 2009;67:80–4.

    Article  Google Scholar 

  5. Bruxel Y, Balbinot A, Zaro MA. Evaluation of impact transmissibility on individuals with shoes and barefoot during human gait. Measurement. 2013;46:2547–54.

    Article  Google Scholar 

  6. Schulc E, Unterberger I, Saboor S, Hilbe J, Ertl M, Ammenwerth E, et al. Measurement and quantification of generalized tonic-clonic seizures in epilepsy patients by means of accelerometry—an explorative study. Epilepsy Res. 2011;95(1–2):173–83. doi:10.1016/j.eplepsyres.2011.02.010.

  7. Rodes CE, Chillrud SN, Haskell WL, Intille SS, Albinali F, Rosenberger ME. Predicting adult pulmonary ventilation volume and wearing compliance by on-board accelerometry during personal level exposure assessments. Atmos Environ. 2012;57:126–37.

    Article  Google Scholar 

  8. Young DJ, Zurcher MA,Semaan M, Megerian CA, Ko WH. MEMS capacitive accelerometer-based middle ear microphone. IEEE Trans Biomed Eng. 2012;59(12):3283–92.

  9. Tura A, Rocchi L, Raggi M, Cutti AG, Chiari L. Recommended number of strides for automatic assessment of gait symmetry and regularity in above-knee amputees by means of accelerometry and autocorrelation analysis. J Neuroeng Rehab. 2012;9(11):1–8.

    Google Scholar 

  10. LeMoyne R, Coroian C, Mastroianni T, Grundfest W. Accelerometers for quantification of gait and movement disorders: a perspective review. J Mech Med Biol. 2008;8(2):137–52.

  11. Kim H, Shin SH, Kim JK, Park YJ, Oh HS, Park YB. Cervical coupling motion characteristics in healthy people using a wireless inertial measurement unit. Evid Based Complement Alternat Med. 2013;2013:8. doi:10.1155/2013/570428.

  12. Pérez R, Costa Ú, Torrent M, Solana J, Opisso E, Cáceres C, et al. Upper limb portable motion analysis system based on inertial technology for neurorehabilitation purposes. Sensors. 2010;10:10733–51.

  13. Sheikh KS, Bryant EC, Glazzard C, Hamel A, Lee RYW. Feasibility of using inertial sensors to assess human movement. Man Ther. 2010;15:122–5.

    Article  Google Scholar 

  14. Vargas AIC, Mercant AG, Williams JM. The use of inertial sensors system for human motion analysis. Phys Ther Rev. 2010;15(6):462–73.

  15. Zhoua H, Stoneb T, Huc H, Harris N. Use of multiple wearable inertial sensors in upper limb motion tracking. Med Eng Phys. 2008;30:123–33.

    Article  Google Scholar 

  16. Shin SH, Ro DH, Lee OS, Oh JH, Kim SH. Within-day reliability of shoulder range of motion measurement with a smartphone. Man Ther. 2012;17:298–304.

    Article  Google Scholar 

  17. Hadjidj A, Souil M, Bouabdallah A, Challal Y, Owen H. Wireless sensor networks for rehabilitation applications: challenges and opportunities. J Netw Comput Appl. 2013;36:1–15.

    Article  Google Scholar 

  18. Zhou H, Hu H. Human motion tracking for rehabilitation: a survey. Biomed Signal Process Control. 2008;3:1–18.

    Article  Google Scholar 

  19. Zhou H, Hu H. Inertial sensors for motion detection of human upper limbs. Sens Rev. 2007;27(2):151–8.

    Article  Google Scholar 

  20. IEEE Standard for Information technology. Telecommunications and information exchange between systems— Local and metropolitan area networks— Specific requirements— Part 15.4: Wireless Medium Access Control (MAC) and Physical Layer (PHY) Specifications for Low-Rate Wireless Personal Area Networks (WPANs)

  21. Tortora GJ, Derrickson BH. Principles of anatomy and physiology. New York: Wiley; 2013. p. 1344.

    Google Scholar 

  22. Denavit J, Hartenberg RS. A kinematic notation for lower-pair mechanisms based on matrices. Trans ASME J Appl Mech. 1955;23:215–21.

    MathSciNet  Google Scholar 

  23. Paul R. Robot manipulators: mathematics, programming, and control: the computer control of robot manipulators. Cambridge: MIT Press; 1981.

    Google Scholar 

  24. Spong MW, Vidyasagar M. Robot dynamics and control. New York: Wiley; 1989.

    Google Scholar 

  25. Legnani G, Casolo F, Righettini P, Zappa B. A homogeneous matrix approach to 3D kinematics and dynamics — I. Theory. Mech Mach Theory. 1996;31(3):573.

    Article  Google Scholar 

  26. Genta G, Morello L. The automotive chassis: system design. New York: Springer; 2009. p. 690.

    Book  Google Scholar 

  27. Faugeras O. Three-dimensional computer vision—a geometric viewpoint. Cambridge: The MIT Press; 1993.

    Google Scholar 

Download references

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical statement

The authors declare that they have no competing interests.

We declare that no party having a direct interest in the results of the research supporting this article has or will confer a benefit on us or on any organization with which we are associated.

All subjects undertook informed-consent procedures as approved by the Research Ethics Committee.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Alexandre Balbinot.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Balbinot, A., de Freitas, J.C.R. & Côrrea, D.S. Use of inertial sensors as devices for upper limb motor monitoring exercises for motor rehabilitation. Health Technol. 5, 91–102 (2015). https://doi.org/10.1007/s12553-015-0110-6

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12553-015-0110-6

Keywords

Navigation