Abstract
In this study, the investigation on lock-in infrared thermography was done for the detection and estimation of artificial subsurface defects size and depth in stainless steel sample. The experimental and the finite element analysis were performed at several excitation frequencies to interrogate the sample ranging from 0.182 down to 0.021 Hz. A finite element model using ‘ANSYS 14.0’ was used to completely simulate the lock-in thermography. The four point method was used in post processing of every pixel of thermal images using the MATLAB programming language. A signal to noise ratio analysis was performed on both phase and amplitude images in each excitation frequency to determine the optimum frequency. The relationship of the phase value with respect to excitation frequency and defect depths was examined. Amplitude image was quantitatively analyzed using Vision Assistant, a special tool in LABVIEW program to acquire the defects size. The phase image was used to calculate the defects depth considering the thermal diffusivity of the material and the excitation frequency for which the defects become visible. A finite element analysis result was found to have good correlation with experimental result and thus demonstrated potentiality in quantification of subsurface defects.
Similar content being viewed by others
Abbreviations
- IRT:
-
Infrared Thermography
- FEA:
-
Finite Element Analysis
- LIT:
-
Lock-in Thermography
- NDT:
-
Non-destructive Testing
- SNR:
-
Signal Noise Ratio
- STS:
-
Stainless Steel
References
McGuire, M. F., “Stainless Steels for Design Engineers,” ASM International, 2008.
Grys, S., “New Thermal Contrast Definition for Defect Characterization by Active Thermography,” Measurement, Vol. 45, No. 7, pp. 1885–1892, 2012.
Maldague, X., “Theory and Practice of Infrared Technology for Nondestructive Testing,” John Wiley & Sons, pp. 355–362, 2001.
Fedala, Y., Streza, M., Sepulveda, F., Roger, J.-P., Tessier, G., and Boué, C., “Infrared Lock-in Thermography Crack Localization on Metallic Surfaces for Industrial Diagnosis,” Journal of Nondestructive Evaluation, Vol. 33, No. 3, pp. 335–341, 2014.
Bagavathiappan, S., Lahiri, B., Saravanan, T., Philip, J., and Jayakumar, T., “Infrared Thermography for Condition Monitoring–A Review,” Infrared Physics & Technology, Vol. 60, pp. 35–55, 2013.
Meola, C. and Carlomagno, G. M., “Recent Advances in the Use of Infrared Thermography,” Measurement Science and Technology, Vol. 15, No. 9, pp. R27–R58, 2004.
Maldague, X., “Infrared Methodology and Technology,” CRC Press, pp. 131–210, 1994.
Maldague, X. and Moore, P., “Infrared and Thermal Testing Nondestructive Testing Handbook, Vol. 3,” American Society for Nondestructive Testing, pp. 40–46, 2001.
Montanini, R., “Quantitative Determination of Subsurface Defects in a Reference Specimen Made of Plexiglas by Means of Lock-in and Pulse Phase Infrared Thermography,” Infrared Physics & Technology, Vol. 53, No. 5, pp. 363–371, 2010.
Czichos, H., “Handbook of Technical Diagnostics: Fundamentals and Application to Structures and Systems,” Springer Science & Business Media, pp. 175–194, 2013.
Liu, J., Yang, W., and Dai, J., “Research on Thermal Wave Processing of Lock-in Thermography based on Analyzing Image Sequences for NDT,” Infrared Physics & Technology, Vol. 53, No. 5, pp. 348–357, 2010.
Kim, G., Hong, S., Kim, G. H., and Jhang, K.-Y., “Evaluation of Subsurface Defects in Fiber Glass Composite Plate using Lock-in Technique,” Int. J. Precis. Eng. Manuf., Vol. 13, No. 4, pp. 465–470, 2012.
Junyan, L., Qingju, T., Xun, L., and Yang, W., “Research on the Quantitative Analysis of Subsurface Defects for Non-Destructive Testing by Lock-in Thermography,” NDT & E International, Vol. 45, No. 1, pp. 104–110, 2012.
Busse, G., “Optoacoustic Phase Angle Measurement for Probing a Metal,” Applied Physics Letters, Vol. 35, No. 10, pp. 759–760, 1979.
Busse, G., Wu, D., and Karpen, W., “Thermal Wave Imaging with Phase Sensitive Modulated Thermography,” Journal of Applied Physics, Vol. 71, No. 8, pp. 3962–3965, 1992.
Busse, G. and Rosencwaig, A., “Subsurface Imaging with Photoacoustics,” Applied Physics Letters, Vol. 36, p. 815, 1980.
Meola, C., Carlomagno, G. M., and Giorleo, L., “Geometrical Limitations to Detection of Defects in Composites by Means of Infrared Thermography,” Journal of Nondestructive Evaluation, Vol. 23, No. 4, pp. 125–132, 2004.
Vavilov, V. P. and Taylor, R., “Theoretical and Practical Aspects of the Thermal NDT of Bonded Structures,” Research Techniques in NDT, Vol. 5, pp. 239–279, 1982.
Maldague, X. and Marinetti, S., “Pulse Phase Infrared Thermography,” Journal of Applied Physics, Vol. 79, No. 5, pp. 2694–2698, 1996.
Maldague, X., Galmiche, F., and Ziadi, A., “Advances in Pulsed Phase Thermography,” Infrared Physics & Technology, Vol. 43, No. 3, pp. 175–181, 2002.
Wu, D. and Busse, G., “Lock-in Thermography for Nondestructive Evaluation of Materials,” Revue Générale de Thermique, Vol. 37, No. 8, pp. 693–703, 1998.
Choi, M., Kang, K., Park, J., Kim, W., and Kim, K., “Quantitative Determination of a Subsurface Defect of Reference Specimen by Lock-in Infrared Thermography,” NDT & E International, Vol. 41, No. 2, pp. 119–124, 2008.
Duan, Y., Huebner, S., Hassler, U., Osman, A., Ibarra-Castanedo, C., and Maldague, X. P., “Quantitative Evaluation of Optical Lock-in and Pulsed Thermography for Aluminum Foam Material,” Infrared Physics & Technology, Vol. 60, pp. 275–280, 2013.
Lahiri, B. B., Bagavathiappan, S., Reshmi, P. R., Philip, J., Jayakumar, T., and Raj, B., “Quantification of Defects in Composites and Rubber Materials using Active Thermography,” Infrared Physics & Technology, Vol. 55, No. 2, pp. 191–199, 2012.
Meola, C., Carlomagno, G. M., Squillace, A., and Giorleo, G., “Non- Destructive Control of Industrial Materials by Means of Lock-in Thermography,” Measurement Science and Technology, Vol. 13, No. 10, pp. 1583–1590, 2002.
Wallbrink, C., Wade, S. A., and Jones, R., “The Effect of Size on the Quantitative Estimation of Defect Depth in Steel Structures using Lock-in Thermography,” Journal of Applied Physics, Vol. 101, No. 10, Paper No. 104907, 2007.
Bai, W. and Wong, B., “Evaluation of Defects in Composite Plates Under Convective Environments using Lock-in Thermography,” Measurement Science and Technology, Vol. 12, No. 2, pp. 142–150, 2001.
Chatterjee, K., Tuli, S., Pickering, S. G., and Almond, D. P., “A Comparison of the Pulsed, Lock-in and Frequency Modulated Thermography Nondestructive Evaluation Techniques,” NDT & E International, Vol. 44, No. 7, pp. 655–667, 2011.
Montanini, R. and Freni, F., “Non-Destructive Evaluation of Thick Glass Fiber-Reinforced Composites by Means of Optically Excited Lock-in Thermography,” Composites Part A: Applied Science and Manufacturing, Vol. 43, No. 11, pp. 2075–2082, 2012.
Grys, S., Vokorokos, L., and Borowik, L., “Size Determination of Subsurface Defect by Active Thermography–Simulation Research,” Infrared Physics & Technology, Vol. 62, pp. 147–153, 2014.
Peng, D. and Jones, R., “Modelling of the Lock-in Thermography Process through Finite Element Method for Estimating the Rail Squat Defects,” Engineering Failure Analysis, Vol. 28, pp. 275–288, 2013.
Streza, M., Fedala, Y., Roger, J., Tessier, G., and Boue, C., “Heat Transfer Modeling for Surface Crack Depth Evaluation,” Measurement Science and Technology, Vol. 24, No. 4, Paper No. 045602, 2013.
Hidalgo-Gato, R., Andrés, J., López-Higuera, J. M., and Madruga, F., “Quantification by Signal to Noise Ratio of Active Infrared Thermography Data Processing Techniques,” Optics and Photonics Journal, Vol. 3, No. 4, pp. 20–26, 2013.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Ranjit, S., Kang, K. & Kim, W. Investigation of lock-in infrared thermography for evaluation of subsurface defects size and depth. Int. J. Precis. Eng. Manuf. 16, 2255–2264 (2015). https://doi.org/10.1007/s12541-015-0290-z
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12541-015-0290-z