Skip to main content
Log in

Investigation of lock-in infrared thermography for evaluation of subsurface defects size and depth

  • Published:
International Journal of Precision Engineering and Manufacturing Aims and scope Submit manuscript

Abstract

In this study, the investigation on lock-in infrared thermography was done for the detection and estimation of artificial subsurface defects size and depth in stainless steel sample. The experimental and the finite element analysis were performed at several excitation frequencies to interrogate the sample ranging from 0.182 down to 0.021 Hz. A finite element model using ‘ANSYS 14.0’ was used to completely simulate the lock-in thermography. The four point method was used in post processing of every pixel of thermal images using the MATLAB programming language. A signal to noise ratio analysis was performed on both phase and amplitude images in each excitation frequency to determine the optimum frequency. The relationship of the phase value with respect to excitation frequency and defect depths was examined. Amplitude image was quantitatively analyzed using Vision Assistant, a special tool in LABVIEW program to acquire the defects size. The phase image was used to calculate the defects depth considering the thermal diffusivity of the material and the excitation frequency for which the defects become visible. A finite element analysis result was found to have good correlation with experimental result and thus demonstrated potentiality in quantification of subsurface defects.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Abbreviations

IRT:

Infrared Thermography

FEA:

Finite Element Analysis

LIT:

Lock-in Thermography

NDT:

Non-destructive Testing

SNR:

Signal Noise Ratio

STS:

Stainless Steel

References

  1. McGuire, M. F., “Stainless Steels for Design Engineers,” ASM International, 2008.

    Google Scholar 

  2. Grys, S., “New Thermal Contrast Definition for Defect Characterization by Active Thermography,” Measurement, Vol. 45, No. 7, pp. 1885–1892, 2012.

    Article  Google Scholar 

  3. Maldague, X., “Theory and Practice of Infrared Technology for Nondestructive Testing,” John Wiley & Sons, pp. 355–362, 2001.

    Google Scholar 

  4. Fedala, Y., Streza, M., Sepulveda, F., Roger, J.-P., Tessier, G., and Boué, C., “Infrared Lock-in Thermography Crack Localization on Metallic Surfaces for Industrial Diagnosis,” Journal of Nondestructive Evaluation, Vol. 33, No. 3, pp. 335–341, 2014.

    Article  Google Scholar 

  5. Bagavathiappan, S., Lahiri, B., Saravanan, T., Philip, J., and Jayakumar, T., “Infrared Thermography for Condition Monitoring–A Review,” Infrared Physics & Technology, Vol. 60, pp. 35–55, 2013.

    Article  Google Scholar 

  6. Meola, C. and Carlomagno, G. M., “Recent Advances in the Use of Infrared Thermography,” Measurement Science and Technology, Vol. 15, No. 9, pp. R27–R58, 2004.

    Article  Google Scholar 

  7. Maldague, X., “Infrared Methodology and Technology,” CRC Press, pp. 131–210, 1994.

    Google Scholar 

  8. Maldague, X. and Moore, P., “Infrared and Thermal Testing Nondestructive Testing Handbook, Vol. 3,” American Society for Nondestructive Testing, pp. 40–46, 2001.

    Google Scholar 

  9. Montanini, R., “Quantitative Determination of Subsurface Defects in a Reference Specimen Made of Plexiglas by Means of Lock-in and Pulse Phase Infrared Thermography,” Infrared Physics & Technology, Vol. 53, No. 5, pp. 363–371, 2010.

    Article  Google Scholar 

  10. Czichos, H., “Handbook of Technical Diagnostics: Fundamentals and Application to Structures and Systems,” Springer Science & Business Media, pp. 175–194, 2013.

    Google Scholar 

  11. Liu, J., Yang, W., and Dai, J., “Research on Thermal Wave Processing of Lock-in Thermography based on Analyzing Image Sequences for NDT,” Infrared Physics & Technology, Vol. 53, No. 5, pp. 348–357, 2010.

    Article  Google Scholar 

  12. Kim, G., Hong, S., Kim, G. H., and Jhang, K.-Y., “Evaluation of Subsurface Defects in Fiber Glass Composite Plate using Lock-in Technique,” Int. J. Precis. Eng. Manuf., Vol. 13, No. 4, pp. 465–470, 2012.

    Article  Google Scholar 

  13. Junyan, L., Qingju, T., Xun, L., and Yang, W., “Research on the Quantitative Analysis of Subsurface Defects for Non-Destructive Testing by Lock-in Thermography,” NDT & E International, Vol. 45, No. 1, pp. 104–110, 2012.

    Article  Google Scholar 

  14. Busse, G., “Optoacoustic Phase Angle Measurement for Probing a Metal,” Applied Physics Letters, Vol. 35, No. 10, pp. 759–760, 1979.

    Article  Google Scholar 

  15. Busse, G., Wu, D., and Karpen, W., “Thermal Wave Imaging with Phase Sensitive Modulated Thermography,” Journal of Applied Physics, Vol. 71, No. 8, pp. 3962–3965, 1992.

    Article  Google Scholar 

  16. Busse, G. and Rosencwaig, A., “Subsurface Imaging with Photoacoustics,” Applied Physics Letters, Vol. 36, p. 815, 1980.

    Article  Google Scholar 

  17. Meola, C., Carlomagno, G. M., and Giorleo, L., “Geometrical Limitations to Detection of Defects in Composites by Means of Infrared Thermography,” Journal of Nondestructive Evaluation, Vol. 23, No. 4, pp. 125–132, 2004.

    Article  Google Scholar 

  18. Vavilov, V. P. and Taylor, R., “Theoretical and Practical Aspects of the Thermal NDT of Bonded Structures,” Research Techniques in NDT, Vol. 5, pp. 239–279, 1982.

    Google Scholar 

  19. Maldague, X. and Marinetti, S., “Pulse Phase Infrared Thermography,” Journal of Applied Physics, Vol. 79, No. 5, pp. 2694–2698, 1996.

    Article  Google Scholar 

  20. Maldague, X., Galmiche, F., and Ziadi, A., “Advances in Pulsed Phase Thermography,” Infrared Physics & Technology, Vol. 43, No. 3, pp. 175–181, 2002.

    Article  Google Scholar 

  21. Wu, D. and Busse, G., “Lock-in Thermography for Nondestructive Evaluation of Materials,” Revue Générale de Thermique, Vol. 37, No. 8, pp. 693–703, 1998.

    Article  Google Scholar 

  22. Choi, M., Kang, K., Park, J., Kim, W., and Kim, K., “Quantitative Determination of a Subsurface Defect of Reference Specimen by Lock-in Infrared Thermography,” NDT & E International, Vol. 41, No. 2, pp. 119–124, 2008.

    Article  Google Scholar 

  23. Duan, Y., Huebner, S., Hassler, U., Osman, A., Ibarra-Castanedo, C., and Maldague, X. P., “Quantitative Evaluation of Optical Lock-in and Pulsed Thermography for Aluminum Foam Material,” Infrared Physics & Technology, Vol. 60, pp. 275–280, 2013.

    Article  Google Scholar 

  24. Lahiri, B. B., Bagavathiappan, S., Reshmi, P. R., Philip, J., Jayakumar, T., and Raj, B., “Quantification of Defects in Composites and Rubber Materials using Active Thermography,” Infrared Physics & Technology, Vol. 55, No. 2, pp. 191–199, 2012.

    Article  Google Scholar 

  25. Meola, C., Carlomagno, G. M., Squillace, A., and Giorleo, G., “Non- Destructive Control of Industrial Materials by Means of Lock-in Thermography,” Measurement Science and Technology, Vol. 13, No. 10, pp. 1583–1590, 2002.

    Article  Google Scholar 

  26. Wallbrink, C., Wade, S. A., and Jones, R., “The Effect of Size on the Quantitative Estimation of Defect Depth in Steel Structures using Lock-in Thermography,” Journal of Applied Physics, Vol. 101, No. 10, Paper No. 104907, 2007.

    Article  Google Scholar 

  27. Bai, W. and Wong, B., “Evaluation of Defects in Composite Plates Under Convective Environments using Lock-in Thermography,” Measurement Science and Technology, Vol. 12, No. 2, pp. 142–150, 2001.

    Article  Google Scholar 

  28. Chatterjee, K., Tuli, S., Pickering, S. G., and Almond, D. P., “A Comparison of the Pulsed, Lock-in and Frequency Modulated Thermography Nondestructive Evaluation Techniques,” NDT & E International, Vol. 44, No. 7, pp. 655–667, 2011.

    Article  Google Scholar 

  29. Montanini, R. and Freni, F., “Non-Destructive Evaluation of Thick Glass Fiber-Reinforced Composites by Means of Optically Excited Lock-in Thermography,” Composites Part A: Applied Science and Manufacturing, Vol. 43, No. 11, pp. 2075–2082, 2012.

    Article  Google Scholar 

  30. Grys, S., Vokorokos, L., and Borowik, L., “Size Determination of Subsurface Defect by Active Thermography–Simulation Research,” Infrared Physics & Technology, Vol. 62, pp. 147–153, 2014.

    Article  Google Scholar 

  31. Peng, D. and Jones, R., “Modelling of the Lock-in Thermography Process through Finite Element Method for Estimating the Rail Squat Defects,” Engineering Failure Analysis, Vol. 28, pp. 275–288, 2013.

    Article  Google Scholar 

  32. Streza, M., Fedala, Y., Roger, J., Tessier, G., and Boue, C., “Heat Transfer Modeling for Surface Crack Depth Evaluation,” Measurement Science and Technology, Vol. 24, No. 4, Paper No. 045602, 2013.

    Article  Google Scholar 

  33. Hidalgo-Gato, R., Andrés, J., López-Higuera, J. M., and Madruga, F., “Quantification by Signal to Noise Ratio of Active Infrared Thermography Data Processing Techniques,” Optics and Photonics Journal, Vol. 3, No. 4, pp. 20–26, 2013.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Wontae Kim.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ranjit, S., Kang, K. & Kim, W. Investigation of lock-in infrared thermography for evaluation of subsurface defects size and depth. Int. J. Precis. Eng. Manuf. 16, 2255–2264 (2015). https://doi.org/10.1007/s12541-015-0290-z

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12541-015-0290-z

Keywords

Navigation