Abstract

Background

The American College of Cardiology/American Society of Nuclear Cardiology published revised appropriate use criteria (AUC) for SPECT MPI in 2009. We assessed adherence to these guidelines and factors associated with inappropriate utilization at the University Medical Center.

Methods

The AUC was applied retrospectively to 420 SPECT MPI studies. Two-sample t test, Fisher’s exact test, and multivariable logistic regression models were used for analysis.

Results

There were 322 appropriate (86%) and 54 (14%) inappropriate studies. The odds of having an inappropriate test increased with younger age (P < .001) and female gender (P < .001). Subjects with diabetes (P = .007) and chest pain (P < .001) were less likely to have an inappropriate test. Academic outpatients were three times more likely to have an inappropriate study (P = .123), while community PCPs were 5.6 times (P = .011) and community cardiologists eight times more likely to order inappropriate tests (P = .031).

Conclusions

Inappropriate SPECT MPI in low risk younger women is an important issue on the USA-Mexico border. Initiatives to reduce inappropriate SPECT MPI should focus on a few indications and evaluation of cardiovascular symptoms in younger age women in outpatient/community practices.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Figure 1

Similar content being viewed by others

References

  1. Mehta R, Ward RP, Chandra S, Agarwal R, Williams KA. Evaluation of the American College of Cardiology Foundation/American Society of Nuclear Cardiology appropriateness criteria for SPECT myocardial perfusion imaging. J Nucl Cardiol 2008;15:337-44.

    Article  PubMed  Google Scholar 

  2. Gibbons RJ, Miller TD, Hodge D, Urban L, Araoz PA, Pellikka P, et al. Application of appropriateness criteria to stress single-photon emission computed tomography sestamibi studies and stress echocardiograms in an academic medical center. J Am Coll Cardiol 2008;51:1283-9.

    Article  PubMed  Google Scholar 

  3. Hendel RC, Cerqueira M, Douglas PS, Caruth KC, Allen JM, Jensen NC, et al. A multicenter assessment of the use of single-photon emission computed tomography myocardial perfusion imaging with appropriateness criteria. J Am Coll Cardiol 2010;55:156-62.

    Article  PubMed  Google Scholar 

  4. Nelson KH, Willens HJ, Hendel RC. Utilization of radionuclide myocardial perfusion imaging in two health care systems: Assessment with the 2009 ACCF/ASNC/AHA appropriateness use criteria. J Nucl Cardiol 2012;19:37-42.

    Article  PubMed  Google Scholar 

  5. Brindis RG, Douglas PS, Hendel RC, Peterson ED, Wolk MJ, Allen JM, et al. ACCF/ASNC appropriateness criteria for single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI): A report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group and the American Society of Nuclear Cardiology endorsed by the American Heart Association. J Am Coll Cardiol 2005;46:1587-605.

    Article  PubMed  Google Scholar 

  6. Hendel RC, Berman DS, Di Carli MF, Heidenreich PA, Henkin RE, Pellikka PA, et al. ACCF/ASNC/ACR/AHA/ASE/SCCT/SCMR/SNM 2009 appropriate use criteria for cardiac radionuclide imaging: A report of the American College of Cardiology Foundation appropriate use criteria task force, the American Society of Nuclear Cardiology, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the Society of Cardiovascular Computed Tomography, the Society for Cardiovascular Magnetic Resonance, and the Society of Nuclear Medicine. J Am Coll Cardiol 2009;53:2201-29.

    Article  PubMed  Google Scholar 

  7. Gibbons RJ, Askew WJ, Hodge D, Miller TD. Temporal trends in compliance with appropriateness criteria for stress single-photon emission computed tomography sestamibi studies in an academic medical center. Am Heart J 2010;159:484-9.

    Article  PubMed  Google Scholar 

  8. Gupta A, Tsiaras SV, Dunsiger SI, Tilkemeier PL. Gender disparity and the appropriateness of myocardial perfusion imaging. J Nucl Cardiol 2011;18:588-94.

    Article  PubMed  Google Scholar 

  9. Carryer DJ, Askew JW, Hodge D, Miller TD, Gibbons RJ. The impact of ordering provider specialty on appropriateness classification. J Nucl Cardiol 2012;19:285-90.

    Article  PubMed  Google Scholar 

  10. Koh AS, Flores JL, Keng FY, Tan RS, Chua TS. Evaluation of the American College of Cardiology Foundation/American Society of Nuclear Cardiology appropriateness criteria for SPECT myocardial perfusion imaging in an Asian Tertiary Cardiac Center. J Nucl Cardiol 2011;18:324-30.

    Article  PubMed  Google Scholar 

  11. Medicare payment advisory commission (MedPAC) report to congress: Improving incentives in the medicare program. 2009. http://www.medpac.gov/documents/Jun09_EntireReport.pdf. Accessed 23 July 2013.

  12. Iglehart JK. The new era of medical imaging—Progress and pitfalls. N Engl J Med 2006;354:2822-8.

    Article  CAS  PubMed  Google Scholar 

  13. Iglehart JK. Health insurers and medical-imaging policy—A work in progress. N Engl J Med 2009;360:1030-7.

    Article  CAS  PubMed  Google Scholar 

  14. Gibbons RJ, Askew JW, Hodge D, Kaping B, Carryer DJ, Miller T. Appropriate use criteria for stress single-photon emission computed tomography sestamibi studies: A quality improvement project. Circulation 2011;123:499-503.

    Article  PubMed  Google Scholar 

  15. Lin FY, Dunning AM, Narula J, Shaw LJ, Gransar H, Berman DS, et al. Impact of an automated multimodality point-of-order decision support tool on rates of appropriate testing and clinical decision making for individuals with suspected coronary artery disease: A prospective multicenter study. J Am Coll Cardiol 2013;62:308-15.

    Article  PubMed  Google Scholar 

  16. Saifi S, Taylor AJ, Allen J, Hendel R. The use of a learning community and online evaluation of utilization for SPECT myocardial perfusion imaging. J Am Coll Cardiol Imaging 2013;6:823-9.

    Article  Google Scholar 

Download references

Disclosures

There is no funding source for this research study. All authors had access to the data and a vital role in the writing of this manuscript.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Omosalewa O. Lalude MBBS, FACC.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lalude, O.O., Gutarra, M.F., Pollono, E.N. et al. Inappropriate utilization of SPECT myocardial perfusion imaging on the USA-Mexico border. J. Nucl. Cardiol. 21, 544–552 (2014). https://doi.org/10.1007/s12350-014-9881-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12350-014-9881-9

Keywords

Navigation