Large metro transfer stations have been widely constructed in China, among which the double-island station faces the serious fire safety issues owing to its large passenger flow. In this paper, simulation cases were carried out to investigate the effectiveness of different ventilation modes by jointly operating tunnel ventilation fan (TVF) and platform screen doors (PSD) under two typical fire scenarios in the platform. The numerical model was established by Fire Dynamics Simulator software and verified via reduced-scale model experiments. The results indicate that the TVF mode of supplying at the end near fire and exhausting at the other end is superior to that of exhausting at both ends. Besides, activating more PSD and TVF on the both sides of platform will restrict smoke in one end to the greater extent. During a fire in the middle of the platform, opening all PSD near tunnel-2 and TVF in tunnel-2 and tunnel-3 is the most appropriate mode. While during a fire at the left end of the platform, activating all PSD and TVF on both sides is the optimal operation mode. The conclusions can provide guidance for smoke control design and on-site emergency ventilation operation in double-island platform fire.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Chen F, Chien SW, Jang HM, Chang WJ (2003). Stack effects on smoke propagation in subway stations. Continuum Mechanics and Thermodynamics, 15: 425–440.

    Article  Google Scholar 

  • Chen P, Zhang Z (2007). Experimental study on fire in shops in subway stations. Journal of Xihua University (Natural Science Edition), 2007(4): 9–10. (in Chinese)

    MathSciNet  Google Scholar 

  • Cheng L, Ueng T, Liu C (2001). Simulation of ventilation and fire in the underground facilities. Fire Safety Journal, 36: 597–619.

    Article  Google Scholar 

  • China Urban Rail Transit Association (2020). Annual statistics and analysis report on urban rail traffic in 2019. (in Chinese)

  • Ding W, Shi CL, Zhong M, Hou Z, Zhang L (2016). Platform screen doors (PSD) model and its implied relation to the subway station fire. Journal of Safety and Environment, 2016(3): 75–79. (in Chinese)

    Google Scholar 

  • Domingo J, Barbero R, Iranzo A, Cuadra D, Servert J, et al. (2011). Analysis and optimization of ventilation systems for an underground transport interchange building under regular and emergency scenarios. Tunnelling and Underground Space Technology, 26: 179–188.

    Article  Google Scholar 

  • Gao R, Li A, Hao X, Lei W, Deng B (2012a). Prediction of the spread of smoke in a huge transit terminal subway station under six different fire scenarios. Tunnelling and Underground Space Technology, 31: 128–138.

    Article  Google Scholar 

  • Gao R, Li A, Hao X, Lei W, Zhao Y, et al. (2012b). Fire-induced smoke control via hybrid ventilation in a huge transit terminal subway station. Energy and Buildings, 45: 280–289.

    Article  Google Scholar 

  • GB 50157-2013 (2013). Code for Design of Metro. Ministry of Housing and Urban-Rural Development of China. (in Chinese)

  • Hao XP (2012). Fire smoke flow and mechanical smoke exhaust mode in subway station. Master Thesis, Xi’an University of Architecture and Technology, China. (in Chinese)

  • Hu L, Wu L, Lu K, Zhang X, Liu S, et al. (2014). Optimization of emergency ventilation mode for a train on fire stopping beside platform of a metro station. Building Simulation, 7: 137–146.

    Article  Google Scholar 

  • Huang RW (2016). Application of air curtain to prevent smoke in subway station. Master Thesis, Chongqing University, China. (in Chinese)

  • Ingason H, Li YZ, Lönnermark A (2015). Tunnel Fire Dynamics. New York: Springer.

    Book  Google Scholar 

  • Ji J, Zhong W, Li KY, Shen XB, Zhang Y, et al. (2011). A simplified calculation method on maximum smoke temperature under the ceiling in subway station fires. Tunnelling and Underground Space Technology, 26: 490–496.

    Article  Google Scholar 

  • Kang K (2007). A smoke model and its application for smoke management in an underground mass transit station. Fire Safety Journal, 42: 218–231.

    Article  Google Scholar 

  • Li YF, Shi BW, Li JM, Fan HM, Du XL (2009). Analysis of the influence of safety gates on station smoke exhaust. In: Proceedings of China Urban Underground Space Development Summit Forum. (in Chinese)

  • Li Y, Lin X, Feng X, Wang C, Li J (2012). Life safety evacuation for cross interchange subway station fire. Procedia Engineering, 45: 741–747.

    Article  Google Scholar 

  • Li YF (2015). Fire Safety Technology of Large Metro Transfer Station. Beijing: Science Press. (in Chinese)

    Google Scholar 

  • Li J, Shi CL, Chen CK, Xu X (2016). Study on switch modes of fully enclosed platform screen doors during fire in underground railway island-type platform. Journal of Safety Science and Technology, 2016(11): 114–119. (in Chinese)

    Article  Google Scholar 

  • Li D, Zhu G (2018). Effect of platform screen doors on mechanical smoke exhaust in subway station fire. Procedia Engineering, 211: 343–352.

    Article  Google Scholar 

  • Liang Q, Li Y, Li J, Xu H, Li K (2017). Numerical studies on the smoke control by water mist screens with transverse ventilation in tunnel fires. Tunnelling and Underground Space Technology, 64: 177–183.

    Article  Google Scholar 

  • Lide DR (2001). Handbook of Chemistry and Physics. Boca Raton, FL, USA: CRC Press.

    Google Scholar 

  • Liu C, Zhong M, Tian X, Zhang P, Li S (2019). Study on emergency ventilation for train fire environment in metro interchange tunnel. Building and Environment, 147: 267–283.

    Article  Google Scholar 

  • Luo N, Li A, Gao R, Tian Z, Hu Z (2014a). Smoke confinement utilizing the USME ventilation mode for subway station fire. Safety Science, 70: 202–210.

    Article  Google Scholar 

  • Luo N, Li A, Gao R, Song T, Zhang W, Hu Z (2014b). Performance of smoke elimination and confinement with modified hybrid ventilation for subway station. Tunnelling and Underground Space Technology, 43: 140–147.

    Article  Google Scholar 

  • McGrattan K, Forney GP (2008). Fire Dynamics Simulator (Version 5), User’s Guide. NIST Special Publication 1019.

  • McGrattan K, Hostikka S, McDermott R, et al. (2016). Fire Dynamics Simulator Technical Reference Guide, Volume 3: Validation. NIST Special Publication 1019, Sixth Edition.

  • Meng N, Hu L, Wu L, Yang L, Zhu S, Chen L, Tang W (2014). Numerical study on the optimization of smoke ventilation mode at the conjunction area between tunnel track and platform in emergency of a train fire at subway station. Tunnelling and Underground Space Technology, 40: 151–159.

    Article  Google Scholar 

  • NFPA (2014). Standard for Fixed Guide Way Transit and Passenger Rail Systems. Quincy, MA, USA: National Fire Protection Association.

    Google Scholar 

  • Park WH, Kim DH, Chang HC (2006). Numerical predictions of smoke movement in a subway station under ventilation. Tunnelling and Underground Space Technology, 21: 304.

    Article  Google Scholar 

  • Rie DH, Hwang MW, Kim SJ, Yoon SW, Ko JW, et al. (2006). A study of optimal vent mode for the smoke control of subway station fire. Tunnelling and Underground Space Technology, 21: 300–301.

    Article  Google Scholar 

  • Roh JS, Ryou HS, Park WH, Jang YJ (2009). CFD simulation and assessment of life safety in a subway train fire. Tunnelling and Underground Space Technology, 24: 447–453.

    Article  Google Scholar 

  • Roh JS, Ryou HS, Yoon SW (2010). The effect of PSD on life safety in subway station fire. Journal of Mechanical Science and Technology, 24: 937–942.

    Article  Google Scholar 

  • Shi CL, Zhong MH, Tu XW, et al. (2009). Fire Experiment and Numerical Analysis of Deep Underground Metro Station. Beijing: Science Press. (in Chinese)

    Google Scholar 

  • Tsukahara M, Koshiba Y, Ohtani H (2011). Effectiveness of downward evacuation in a large-scale subway fire using Fire Dynamics Simulator. Tunnelling and Underground Space Technology, 26: 573–581.

    Article  Google Scholar 

  • Wang W, He T, Huang W, Shen R, Wang Q (2018). Optimization of switch modes of fully enclosed platform screen doors during emergency platform fires in underground metro station. Tunnelling and Underground Space Technology, 81: 277–288.

    Article  Google Scholar 

  • Wu W, You S (2009). Analysis to ventilation effectiveness in subway fire environment. In: Proceedings of the 4th IEEE Conference on Industrial Electronics and Applications (ICIEA) Xi’an, China.

  • Yang Y, Cao LY (2006). Discussion on subway fire scenario design. Journal of Natural Disasters, 4: 125–129. (in Chinese)

    Google Scholar 

  • Yuan JP, Liao YJ, Zhou SD, Tang Z, Fang Z (2015). Smoke extraction model of station hall fire in large subway transfer station. Engineering Journal of Wuhan University, 2015(6): 805–808. (in Chinese)

    Google Scholar 

  • Zhang Y (2014). Numerical analysis of smoke exhaust system design of metro double-island station. Fire Technology & Products Information, 2014(4): 15–19. (in Chinese)

    Google Scholar 

  • Zhao D, Jiang J, Zhou R, Tong Y, Wu F, Shi L (2016). Numerical study on the optimisation of smoke ventilation mode for interchange subway station fire. International Journal of Ventilation, 15: 79–93.

    Article  Google Scholar 

  • Zhong W (2007). Study on smoke flow characteristics and control methods in subway station fire. PhD Thesis, University of Science and Technology of China, China. (in Chinese)

  • Zhong W, Ji J, Yang JP, Huo R, Wang H (2010). Experimental and simulation study on the influence of smoke vent arrangement on smoke control effect in subway station. Engineering Mechanics, 27(3): 163–168. (in Chinese)

    Google Scholar 

  • Zhong MH, Shi CL, Luo YP, et al. (2012). Progress in research on complex subway fire smoke control technology. In: Proceedings of the 20th Cross-Strait and Hong Kong and Macao Occupational Safety and Health Symposium and China Occupational Safety and Health Association 2012 Academic Annual meeting.

  • Zhou Y, Bu R, Xu Z, Chen H, Gong J (2018). Numerical simulation of smoke control effectiveness with different exhaust modes in a large subway station. Procedia Engineering, 211: 1065–1074.

    Article  Google Scholar 

  • Zhu H, Shen Y, Yan Z, Guo Q, Guo Q (2016). A numerical study on the feasibility and efficiency of point smoke extraction strategies in large cross-section shield tunnel fires using CFD modeling. Journal of Loss Prevention in the Process Industries, 44: 158–170.

    Article  Google Scholar 

Download references

Acknowledgements

This work was supported by the National Natural Science Foundation of China (51674152, 71790613, 51906123), the National Outstanding Youth Science Foundation (51425404).

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Maohua Zhong.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Long, Z., Yang, Y., Liu, C. et al. Study on the optimal operation mode of ventilation system during metro double-island platform fire. Build. Simul. 14, 779–792 (2021). https://doi.org/10.1007/s12273-020-0692-4

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12273-020-0692-4

Keywords

Navigation