The efficiency of air curtain in reducing infiltration and associated energy usage is currently evaluated statically by using an efficiency factor, η air, based on single steady/static condition, which is often not the case for actual buildings under variable weather conditions and door usages. Based on a new method to consider these dynamic effects on air curtains, this study uses a dynamic efficiency factor η B in terms of whole building site end-use energy to assess the efficiency of air curtains when compared to single doors (i.e. without air curtains) and vestibule doors. Annual energy simulations were conducted for two reference building models considering their specific door usage schedules in 16 climate zone locations in the North America. The variations of the proposed efficiency factor for different climate zones illustrated the dynamic impacts of weather, building, unit fan energy and door usage frequency on air curtain efficiency. A sensitivity study was also conducted for the operation temperature conditions of air curtain and showed that η B also considers these operational conditions. It was thus concluded that using whole building site end-use energy to calculate the efficiency factor, ηB, can provide more realistic estimates of the performance of air curtains operations in buildings than the existing static efficiency factor.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Alamdari F (1997). Air Curtains commercial applications—Application Guide 2/97. Berkshire, UK: The Building Services Research and Information Association.

    Google Scholar 

  • ANSYS (2011). ANSYS FLUENT User’s Guide—Release 14.0. Canonsburg, PA, USA: ANSYS.

  • ASHRAE (2010). ASHRAE Standard 90.1-2010: Energy Standard for Buildings Except Low-Rise Residential Buildings. Atlanta, GA, USA: American Society of Heating, Refrigerating and Air-Conditioning Engineers.

  • ASHRAE (2013). ASHRAE Handbook—Fundamentals. Atlanta, GA, USA: American Society of Heating, Refrigerating and Air-Conditioning Engineers.

    Google Scholar 

  • ASHRAE (2015). ASHRAE Handbook—HVAC Applications. Atlanta, GA, USA: American Society of Heating, Refrigerating and Air-Conditioning Engineers.

    Google Scholar 

  • Chen Y-G (2009). Parametric evaluation of refrigerated air curtains for thermal insulation. International Journal of Thermal Sciences, 48: 1988–1996.

    Article  Google Scholar 

  • Cho H, Liu B, Gowri K (2010). Energy saving impact of ASHRAE 90.1 Vestibule Requirements: Modeling of Air Infiltration Through Door Openings. Richland, WA, USA: Pacific Northwest National Laboratory.

    Book  Google Scholar 

  • Commercial Prototype Building Models Building Energy Codes Program (2016). US Department of Energy. Available at https://www.energycodes.gov/commercial-prototype-building-models, Accessed 1 Dec15.

  • Costa JJ, Oliveira LA, Silva MCG (2006). Energy savings by aerodynamic sealing with a downward-blowing plane air curtain—A numerical approach. Energy and Buildings, 38: 1182–1193.

    Article  Google Scholar 

  • Crawley DB (1998). Which weather data should you use for energy simulations of commercial buildings? ASHRAE Transactions, 104(2): 498–515.

    Google Scholar 

  • Deru M, Field K, Studer D, Benne K, Griffith B, et al. (2011). US Department of Energy Commercial Reference Building Models of the National Building Stock. Golden, CO, USA: National Renewable Energy Laboratory.

    Book  Google Scholar 

  • DOE (2010). EnergyPlus. Engineering Reference. The Reference to EnergyPlus Calculations. US Department of Energy.

  • Emmerich SJ, Persily AK (1998). Energy impacts of infiltration and ventilation in U.S. office buildings using multizone airflow simulation. In: Proceedings of IAQ and Energy 98 Conference, New Orleans, USA, pp. 191–203.

    Google Scholar 

  • Foster AM, Swain MJ, Barrett R, D’Agaro P, James SJ (2006). Effectiveness and optimum jet velocity for a plane jet air curtain used to restrict cold room infiltration. International Journal of Refrigeration, 29: 692–699.

    Article  Google Scholar 

  • Goubran S, Qi D, Wang L (2015). Annual energy saving impact of air curtains in commercial reference buildings. In: Proceedings of ISHVAC-COBEE, Tianjin, China.

    Google Scholar 

  • Hayes FC (1968). Heat transfer characteristics of the air curtain: A Plane jet subjected to transverse pressure and temperature gradients. PhD Thesis, University of Illinois, USA.

    Google Scholar 

  • Hayes FC, Stoecker WF (1969a). Design data for air curtains. ASHRAE Transactions, 75(2): 168–180.

    Google Scholar 

  • Hayes FC, Stoecker WF (1969b). Heat transfer characteristics of the air curtain. ASHRAE Transactions, 75(2): 153–167.

    Google Scholar 

  • Howell R (2008). Design & Application Guide: Air Curtains. Leading Edge.

    Google Scholar 

  • Johnson D, Thomas P, Kordecki L (2008). Air Curtains: A Proven Alternative to Vestibule Design. New Castle, PA, USA: Berner International Corporation.

    Google Scholar 

  • Karlsson N (2013). Air infiltration through building entrances. Master Thesis, Chalmers University of Technology, Sweden.

    Google Scholar 

  • Pappas TC, Tassou SA (2003). Numerical investigations into the performance of doorway vertical air curtains in air-conditioned spaces. ASHRAE Transactions, 109(1): 273–279.

    Google Scholar 

  • Qi D, Goubran S, Zmeureanu R, Wang L (2015). Effect of People on Infiltration of Building Entrance with Air Curtains. In: Proceedings of ISHVAC-COBEE, Tianjin, China.

    Google Scholar 

  • Sirén K (2003). Technical dimensioning of a vertically upwardsblowing air curtain—Part I. Energy and Buildings, 35: 697–705.

    Article  Google Scholar 

  • Van Belleghem M, Verhaeghe G, T’Joen C, Huisseune H, De Jaeger P, De Paepe M (2012). Heat transfer through vertically downwardblowing single-jet air curtains for cold rooms. Heat Transfer Engineering, 33: 1196–1206.

    Article  Google Scholar 

  • Verhaeghe G, Van Belleghem M (2010). Study of air curtains used to restrict infiltration into refrigerated rooms. In: Proceedings of 7th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics (HEFAT 2010), Antalya, Turkey.

    Google Scholar 

  • Wang L (2013). Investigation of the Impact of Building Entrance Air Curtain on Whole Building Energy Use. Arlington Heights, IL, USA: Air Movement and Control Association.

    Google Scholar 

  • Wang L, Zhong Z (2014). An approach to determine infiltration characteristics of building entrance equipped with air curtains. Energy and Buildings, 75: 312–320.

    Article  Google Scholar 

  • Yuill GK (1996). Impact of high use automatic doors on infiltration. ASHRAE Research Project 763-TRP. Atlanta, GA, USA: American Society of Heating, Refrigerating and Air-Conditioning Engineers.

    Google Scholar 

  • Yuill GK, Upham R, Hui C (2000). Air leakage through automatic doors. ASHRAE Transactions, 106(2): 145–160.

    Google Scholar 

Download references

Acknowledgements

The authors acknowledge the financial and technical support from the Air Management and Control Association (AMCA), Mars Air Systems, Berner International, Powered Aire and Inter Code Incorporated. The authors would also like thank Mrs. Bing Liu and Mr. Rahul Athalye at the Pacific Northwest National Laboratory (PNNL) for answering various inquiries regarding energy modeling and DOE reference building models’ details.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Liangzhu Leon Wang.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Goubran, S., Qi, D. & Wang, L.L. Assessing dynamic efficiency of air curtain in reducing whole building annual energy usage. Build. Simul. 10, 497–507 (2017). https://doi.org/10.1007/s12273-017-0349-0

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12273-017-0349-0

Keywords

Navigation